Duke Lesley-LR080103
Rone En2==
Client:
Duke Construction, LP
14241 Dallas Pkwy, Ste 1000
Dallas, TX 75254-2936
8908 Ambassador Row, Dallas, TX 75247
7701 W Little York, Ste 600, Houston, TX 77040
4421 Freldrich, Ste 195, Austin, TX 78744
Corporate Phone: (214) 630-9745
Report of Concrete Com pressive Strength Test
Report No.: 304108
Project No.: 0612510
Date of Service: 11/02/2007
Report Date: 01/03/2008
Project: Lesley Infrastructure
Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
PROJECT DATA
Contractor:
Concrete Supplier: TXI
Plant: 141
Specification Requirements
Strength: 4,000 psi @ 28 days
Slump (in.): 3" - 5"
Air (%): 3% - 6%
Test Method: ASTM C-172
ASTM C-31 (except 10.1.2)
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-138
ASTM C-39
Mix Design 1.0.: 88274
Placement Date: 11/02/2007
Weather Conditions: Cloudy
Time Sampled: 11 :30am
Temperature - Air: 750F
Truck No: 1574
Air Content: 1.5%
Overall Placement Location:
Point West Boulevard south, approach Beltline
Measured
Slump
(inches)
5.0
Batch time: 10:57am
Concrete: 800F
Ticket No: 565426
Unit Weight (pet): NA
Sample Location:
Westbound approach, concrete crosswalk, west boulevard off Beltline
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12"
Cylinder Maximum Compressive
Marked Date Age Diameter Area Load Strength Fracture
Set No. Tested (days) (in) (inZ) (Ibs) (psi) Type
1 1 11/09/2007 7 6.00 28.27 100,080 3,540 Cone/Split
1 2 11/30/2007 28 6.00 28.27 147,510 t;20 Shear
1 3 11/30/2007 28 6.00 28.27 155,240 5 90 Cone/Shear
Average 5,350
1 4 12/28/2007 56 28.27 164,450 5,820 Cone/Split
Technician: Raymond Moore
Report Distribution:
Orig: Duke Construction, LP (Dallas, TX)
Alln: Mr. Alex Bennell PE (1-ec copy)
1-ec Lacy Construction Alln: Mr. Kevin Briles
1-cc City of Coppell Alln: Mr. Lee Stone
1-cc City of Coppell Alln: Mr. Larry Davis
('II J-/
J
K. Scott Watson, AET
Project Manager
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd.
(CH/KW) Page 1 of 1