Report of Concrete Compressive Strength Test
Report No.: 304290
Project No.: 0712932
Date of Service: 11/05/2007
Report Date: 01/04/2008
Project: Hemisphere's at Point West
Coppell, Texas
Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
PROJECT DATA
Contractor: Duke Construction, LP
Concrete Supplier: Potter Concrete
Plant: 10
Specification Requirements
Strength: 4,000 psi @ 28 days
Slump (in.): 4" - 6"
Air (%): 3% - 5%
Test Method: ASTM C-172
ASTM C-31 (except 10.1.2)
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-138
ASTM C-39
Mix Design 1.0.: 7753 PW
Placement Date: 11/05/2007
Weather Conditions: Clear
Time Sampled: 03:10am
Temperature - Air: 550F
Truck No: 140
Air Content: 4.1 %
Overall Placement Location:
Paving at Point West VII - northeast corner of trailer parking and east fire
lane/approach
Batch time: 02:57am
Concrete: 820F
Ticket No: 8772
Unit Weight (pet): NA
Measured
Slump
(inches)
4.0
Sample Location:
50' north, 15' west from northeast corner of building
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12"
Cylinder Maximum Compressive
Marked Date Age Diameter Area Load Strength Fracture
Set No. Tested (days) (in) (in') (Ibs) (psi) Type
1 1 11/12/2007 7 6.00 28.27 128,750 4,550 Cone/Split
2 12/03/2007 28 6.00 28.27 169,460 5,990 Cone/Split
3 12/03/2007 28 6.00 28.27 163,120 5,770 Shear
Average 5,880
4 12/31/2007 56 6.00 28.27 178,150 6,300 Shear
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition. appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd.
(DM/KW) Page 1 of 9
Rone En~~
8908 Ambassador Row, Dallas, TX 75247
7701 W Little York, Ste 600, Houston, TX 77040
4421 Freidrich, Ste 195, Austin, TX 78744
Corporate Phone: (214) 630-9745
Client:
Duke Construction, LP
14241 Dallas Pkwy, Ste 1000
Dallas, TX 75254-2936
Report of Concrete Compressive Strength Test
Report No.: 304290
Project No.: 0712932
Date of Service: 11/05/2007
Report Date: 01/04/2008
Project: Hemisphere's at Point West
Coppell, Texas
Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
PROJECT DATA
Contractor: Duke Construction, LP
Concrete Supplier: Potter Concrete
Plant: 10
Specification Requirements
Strength: 4,000 psi @ 28 days
Slump (in.): 4" - 6"
Air (%): 3% - 5%
Test Method: ASTM C-172
ASTM C-31 (except 10.1.2)
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-138
ASTM C-39
Mix Design I.D.: 7753 PW
Placement Date: 11/05/2007
Weather Conditions: Clear
Time Sampled: 04:15am
Temperature - Air: 550F
Truck No: 109
Air Content: 1.3%
Overall Placement Location:
Paving at Point West VII - northeast corner of trailer parking and east fire
lane/approach
Batch time: 04:00am
Concrete: 820F
Ticket No: 8779
Unit Weight (pet): NA
Measured
Slump
(inches)
4.25
Sample Location:
75' north, 10' east from northeast corner of building
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12"
Cylinder Maximum Compressive
Marked Date Age Diameter Area Load Strength Fracture
Set No. Tested (days) (in) (in') (Ibs) (psi) Type
2 1 11/12/2007 7 6.00 28.27 115,670 4,090 Cone/Split
2 2 12/03/2007 28 6.00 28.27 149,660 5,290 Cone/Shear
2 3 12/03/2007 28 6.00 28.27 156,090 5,520 Cone/Split
Average 5,410
2 4 12/31/2007 56 6.00 28.27 169,890 6,010 Shear
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd.
(DMlKW) Page 2 of 9
Rone Engineering
.
8908 Ambassador Row, Dallas, TX 75247
7701 W Little York, Ste 600, Houston, TX 77040
4421 Freidrich, Ste 195, Austin, TX 78744
Corporate Phone: (214) 630-9745
Client:
Duke Construction, LP
14241 Dallas Pkwy, Ste 1000
Dallas, TX 75254-2936
Report of Concrete Compressive Strength Test
Report No.: 304290
Project No.: 0712932
Date of Service: 11/05/2007
Report Date: 01/04/2008
Project: Hemisphere's at Point West
Coppell, Texas
Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
PROJECT DATA
Contractor: Duke Construction, LP
Concrete Supplier: Potter Concrete
Plant: 10
Specification Requirements
Strength: 4,000 psi @ 28 days
Slump (in.): 4" - 6"
Air (%): 3% - 5%
Test Method: ASTM C-172
ASTM C-31 (except 10.1.2)
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-138
ASTM C-39
Mix Design I.D.: 7753 PW
Placement Date: 11/05/2007
Weather Conditions: Clear
Time Sampled: 05:40am
Temperature - Air: 580F
Truck No: 101
Air Content: 4.8%
Overall Placement Location:
Paving at Point West VII - northeast corner of trailer parking and east fire
lane/approach
Batch time: 05:14am
Concrete: 820F
Ticket No: 8792
Unit Weight (pet): NA
Measured
Slump
(inches)
5.5
Sample Location:
40' north, 25' east from northeast corner of building
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12"
Cylinder Maximum Compressive
Marked Date Age Diameter Area Load Strength Fracture
Set No. Tested (days) (in) (in') (Ibs) (psi) Type
3 1 11/12/2007 7 6.00 28.27 86,650 3,060 Cone/Split
3 2 12/03/2007 28 6.00 28.27 110,840 3,920 Cone/Split
3 3 12/03/2007 28 6.00 28.27 110,360 3,900 Cone/Split
Average 3,910 *
3 4 12/31/2007 56 6.00 28.27 118,130 4,180 Shear
* Does not comply with specified strength
Remarks: Water added at site: 5 gallons
LIMIT A nONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd.
(DM/KW) Page 3 019
Rone Engineering
.
Client:
Duke Construction, LP
14241 Dallas Pkwy, Ste 1000
Dallas, TX 75254-2936
8908 Ambassador Row, Dallas, TX 75247
7701 W Little York, Ste 600, Houston, TX 77040
4421 Freidrlch, Ste 195, Austin, TX 78744
Corporate Phone: (214)630-9745
Report of Concrete Compressive Strength Test
Report No.: 304290
Project No.: 0712932
Date of Service: 11/05/2007
Report Date: 01/04/2008
Project: Hemisphere's at Point West
Coppell, Texas
Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
Contractor: Duke Construction, LP
Concrete Supplier: Potter Concrete
Plant: 10
Specification Requirements
Strength: 4,000 psi @ 28 days
Slump (in.): 4" - 6"
Air (%): 3% - 5%
Test Method: ASTM C-172
ASTM C-31 (except 10.1.2)
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-138
ASTM C-39
PROJECT DATA
Mix Design I.D.: 7753 PW
Placement Date: 11/05/2007
Weather Conditions: Sunny, clear
Time Sampled: 06:50am Batch time: 06:34am
Temperature - Air: 600F Concrete: 850F
Truck No: 130 Ticket No: 8803
Air Content: 4.5% Unit Weight (pcf): NA
Overall Placement Location:
Paving at Point West VII - northeast corner of trailer parking and east fire
lane/approach
Measured
Slump
(inches)
5.75
Sample Location:
15' north, 50' east from northeast corner of building
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12"
Cylinder Maximum Com pressive
Marked Date Age Diameter Area Load Strength Fracture
Set No. Tested (days) (in) (in') (Ibs) (psi) Type
4 1 11/12/2007 7 6.00 28.27 83,520 2,950 Cone/Shear
4 2 12/03/2007 28 6.00 28.27 107,880 3,820 Shear
4 3 12/03/2007 28 6.00 28.27 110,380 3,900 Cone/Split
Average 3,860 *
4 4 12/31/2007 56 6.00 28.27 122,290 4,330 Cone/Split
* Does not comply with specified strength
Remarks: Water added at site: 10 gallons
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd.
(DMlKW) Page 4 of 9
Rone Engineering
.
Client:
Duke Construction, LP
14241 Dallas Pkwy, Ste 1000
Dallas, TX 75254-2936
8908 Ambassador Row, Dallas, TX 75247
7701 W Little York, Ste 600, Houston, TX 77040
4421 Freldrich, Ste 195, Austin, TX 78744
Corporate Phone: (214) 630-9745
Report of Concrete Compressive Strength Test
Report No.: 304290
Project No.: 0712932
Date of Service: 11/05/2007
Report Date: 01/04/2008
Project: Hemisphere's at Point West
Coppell, Texas
Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
Contractor: Duke Construction, LP
Concrete Supplier: Potter Concrete
Plant: 10
Specification Requirements
Strength: 4,000 psi @ 28 days
Slump (in.): 4" - 6"
Air (%): 3% - 5%
Test Method: ASTM C-172
ASTM C-31 (except 10.1.2)
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-138
ASTM C-39
PROJECT DATA
Mix Design 1.0.: 7753 PW
Placement Date: 11/05/2007
Weather Conditions: Sunny, clear
Time Sampled: 07:45am Batch time: 07:25am
Temperature - Air: 600F Concrete: 850F
Truck No: 101 Ticket No: 8810
Air Content: 4.6% Unit Weight (pet): NA
Overall Placement Location:
Paving at Point West VII - northeast corner of trailer parking and east fire
lane/approach
Measured
Slump
(inches)
5.0
Sam pie Location:
40' east from northeast corner of building
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12"
Cylinder Maximum Compressive
Marked Date Age Diameter Area Load Strength Fracture
Set No. Tested (days) (in) (In2) (Ibs) (psi) Type
5 1 11/12/2007 7 6.00 28.27 120,990 4,280 Cone/Split
5 2 12/03/2007 28 6.00 28.27 134,620 4,760 Shear
5 3 12/03/2007 28 6.00 28.27 135,730 4,800 Shear
Average 4,780
5 4 12/31/2007 56 6.00 28.27 154,340 5,460 Cone/Split
Remarks: Water added at site: 10 gallons
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd.
(DMlKW) Page 5 of 9
Rone Engineering
.
Client:
Duke Construction, LP
14241 Dallas Pkwy, Ste 1000
Dallas, TX 75254-2936
8908 Ambassador Row, Dallas, TX 75247
7701 W Little York, Ste 600, Houston, TX 77040
4421 Freidrich, Ste 195, Austin, TX 78744
Corporate Phone: (214) 630-9745
Report of Concrete Compressive Strength Test
Report No.: 304290
Project No.: 0712932
Date of Service: 11/05/2007
Report Date: 01/04/2008
Project: Hemisphere's at Point West
Coppell, Texas
Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
Contractor: Duke Construction, LP
Concrete Supplier: Potter Concrete
Plant: 10
Specification Requirements
Strength: 4,000 psi @ 28 days
Slump (in.): 4" - 6"
Air (%): 3% - 5%
Test Method: ASTM C-172
ASTM C-31 (except 10.1.2)
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-138
ASTM C-39
PROJECT DATA
Mix Design I.D.: 7753 PW
Placement Date: 11/05/2007
Weather Conditions: Sunny, clear
Time Sampled: 10:30am Batch time: 10:08am
Temperature - Air: 700F Concrete: 900F
Truck No: 138 Ticket No: 8823
Air Content: 4.6% Unit Weight (pet): NA
Overall Placement Location:
Paving at Point West VII - northeast corner of trailer parking and east fire
lane/approach
Measured
Slump
(inches)
4.75
Sample Location:
50' east, 25' south from northeast corner of building
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12"
Cylinder Maximum Compressive
Marked Date Age Diameter Area Load Strength Fracture
Set No. Tested (days) (in) (inZ) (Ibs) (psi) Type
6 1 11/12/2007 7 6.00 28.27 79,360 2,810 Cone/Split
6 2 12/03/2007 28 6.00 28.27 110,030 3,890 Cone/Split
6 3 12/03/2007 28 6.00 28.27 117,980 4,170 Cone/Shear
Average 4,030
6 4 12/31/2007 56 6.00 28.27 130,910 4,630 Shear
Remarks: Water added at site: 5 gallons
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd.
(DM/KW) Page 6 of 9
Rone Engineering
.
Client:
Duke Construction, LP
14241 Dallas Pkwy, Ste 1000
Dallas, TX 75254-2936
8908 Ambassador Row, Dallas, TX 75247
7701 W Little York, Ste 600, Houston, TX 77040
4421 Freidrich, Ste 195, Austin, TX 78744
Corporate Phone: (214) 630-9745
Report of Concrete Compressive Strength Test
Report No.: 304290
Project No.: 0712932
Date of Service: 11/05/2007
Report Date: 01/04/2008
Project: Hemisphere's at Point West
Coppell, Texas
Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
Contractor: Duke Construction, LP
Concrete Supplier: Potter Concrete
Plant: 10
Specification Requirements
Strength: 4,000 psi @ 28 days
Slump (in.): 4" - 6"
Air (%): 3% - 5%
Test Method: ASTM C-172
ASTM C-31 (except 10.1.2)
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-138
ASTM C-39
PROJECT DATA
Mix Design 1.0.: 7753 PW
Placement Date: 11/05/2007
Weather Conditions: Sunny, clear
Time Sampled: 11 :55am Batch time: 11 :35am
Temperature - Air: 750F Concrete: 900F
Truck No: 140 Ticket No: 8838
Air Content: 1.5% Unit Weight (pet): NA
Overall Placement Location:
Paving at Point West VII - northeast corner of trailer parking and east fire
lane/approach
Measured
Slump
(inches)
4.0
Sample Location:
30' east, 90' south from northeast corner of building
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12"
Cylinder Maximum Compressive
Marked Date Age Diameter Area Load Strength Fracture
Set No. Tested (days) (in) (in2) (Ibs) (psi) Type
7 1 11/12/2007 7 6.00 28.27 109,080 3,860 Cone/Split
7 2 12/03/2007 28 6.00 28.27 133,600 4,730 Shear
7 3 12/03/2007 28 6.00 28.27 130,610 4,620 Cone/Split
Average 4,670
7 4 12/31/2007 56 6.00 28.27 159,890 5,650 Cone/Split
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd.
(DMlKW) Page 7 of 9
Rone Engineering
.
Client:
Duke Construction, LP
14241 Dallas Pkwy, Ste 1000
Dallas, TX 75254-2936
8908 Ambassador Row, Dallas, lX 75247
7701 W Little York, Ste 600, Houston, lX 77040
4421 Freidrich, Ste 195, Austin, TX 78744
Corporate Phone: (214) 630-9745
Report of Concrete Compressive Strength Test
Report No.: 304290
Project No.: 0712932
Date of Service: 11/05/2007
Report Date: 01/04/2008
Project: Hemisphere's at Point West
Coppell, Texas
Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
Contractor: Duke Construction, LP
Concrete Supplier: Potter Concrete
Plant: 10
Specification Requirements
Strength: 4,000 psi @ 28 days
Slump (in.): 4" - 6"
Air (%): 3% - 5%
Test Method: ASTM C-172
ASTM C-31 (except 10.1.2)
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-138
ASTM C-39
PROJECT DATA
Mix Design I.D.: 7753 PW
Placement Date: 11/05/2007
Weather Conditions: Sunny, clear
Time Sampled: 01:45pm Batch time: 01:16pm
Temperature - Air: 800F Concrete: 920F
Truck No: 126 Ticket No: 15677
Air Content: 4.9% Unit Weight (pcf): NA
Overall Placement Location:
Paving at Point West VII - northeast corner of trailer parking and east fire
lane/approach
Measured
Slump
(inches)
4.5
Sample Location:
45' east, 140' south from northeast corner of building
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12"
Cylinder Maximum Compressive
Marked Date Age Diameter Area Load Strength Fracture
Set No. Tested (days) (in) (in') (Ibs) (psi) Type
8 1 11/12/2007 7 6.00 28.27 106,910 3,780 Cone/Split
8 2 12/03/2007 28 6.00 28.27 132,390 4,680 Cone/Shear
8 3 12/03/2007 28 6.00 28.27 115.420 4,080 Shear
Average 4,380
8 4 12/31/2007 56 6.00 28.27 144,850 5,120 Shear
L1MITA liONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, etc.) or any other feature of similar SUbject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd.
(DMlKW) Page 8 of 9
Rone Engineering
.
Client:
Duke Construction, LP
14241 Dallas Pkwy, Ste 1000
Dallas, TX 75254-2936
8908 Ambassador Row, Dallas, TX 75247
7701 W LitUe York, Ste 600, Houston, TX 77040
4421 Freidrich, Ste 195, Austin, TX 78744
Corporate Phone: (214) 630-9745
Report of Concrete Compressive Strength Test
Report No.: 304290
Project No.: 0712932
Date of Service: 11/05/2007
Report Date: 01/04/2008
Project: Hemisphere's at Point West
Coppell, Texas
Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
Contractor: Duke Construction, LP
Concrete Supplier: Potter Concrete
Plant: 10
Specification Requirements
Strength: 4,000 psi @ 28 days
Slump (in.): 4" - 6"
Air ('Yo): 3% - 5%
Test Method: ASTM C-172
ASTM C-31 (except 10.1.2)
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-138
ASTM C-39
PROJECT DATA
Mix Design 1.0.: 7753 PW
Placement Date: 11/05/2007
Weather Conditions: Sunny, clear
Time Sampled: 03:00pm Batch time: 02:32pm
Temperature - Air: 820F Concrete: 920F
Truck No: 130 Ticket No: 8852
Air Content: 4.5% Unit Weight (pet): NA
Overall Placement Location:
Paving at Point West VII - northeast corner of trailer parking and east fire
lane/approach
Measured
Slump
(inches)
6.5
Sample Location:
50' east, 200' south from northeast corner of building
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12"
Cylinder Maximum Compressive
Marked Date Age Diameter Area Load Strength Fracture
Set No. Tested (days) (in) (in') (Ibs) (psi) Type
9 1 11/12/2007 7 6.00 28.27 78,900 2,790 Cone/Split
9 2 12/03/2007 28 6.00 28.27 124,380 4,400 Shear
9 3 12/03/2007 28 6.00 28.27 121,940 4,310 Cone/Split
Average 4,360
9 4 12/31/2007 56 6.00 28.27 138,040 4,880 Cone/Split
Started: 02:00am Finished: 04:00pm
Technician: Montreal Bailey
Report Distribution:
Orig: Duke Construction, LP (Dallas, TX) AUn: Mr. Paul Byrne
(1-ec copy)
1-cc PoUer Concrete AUn: Mr Ryan Skelly
1-cc City of Coppell AUn: Mr. Lee Stone
1-cc City of Coppell AUn: Mr. Larry Davis
Rone Engineering
,~~
K. Scott Watson, AET
Project Manager
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd.
(DM/KW) Page 9 of 9
Rone Engineering
.
Client:
Duke Construction, LP
14241 Dallas Pkwy, Ste 1000
Dallas, TX 75254-2936
8908 Ambassador Row, Dallas, TX 75247
7701 W Little York, 8te 600, Houston, TX 77040
4421 Freidrlch, 8te 195, Austin, TX 78744
Corporate Phone: (214) 630-9745
Report of Concrete Compressive Strength Test
Report No.: 307153
Project No.: 0712932
Date of Service: 12/04/2007
Report Date: 01/04/2008
Project: Hemisphere's at Point West
Coppell, Texas
Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
Contractor: Duke Construction, LP
Concrete Supplier: Potter Concrete
Plant: 10
Specification Requirements
Strength: 4,000 psi @ 28 days
Slump (in.): 4" - 6"
Air (%): 3% - 5%
Test Method: ASTM C-172
ASTM C-31 (except 10.1.2)
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-138
ASTM C-39
PROJECT DATA
Mix Design 1.0.: 7753PW
Placement Date: 12/04/2007
Weather Conditions: Clear
Time Sampled: 03:00am
Temperature - Air: 400F
Truck No: 108
Air Content: 4.1 %
Overall Placement Location:
Paving
Batch time: 02:45am
Concrete: 800F
Ticket No: 9655
Unit Weight (pet): NA
Measured
Slump
(inches)
5.0
Sample Location:
150' north, 10' east from northwest building corner
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12"
Cylinder Maximum Compressive
Marked Date Age Diameter Area Load Strength Fracture
Set No. Tested (days) (in) (in2) (Ibs) (psi) Type
1 1 12/11/2007 7 6.00 28.27 96,700 3,420 Type5
1 2 01/01/2008 28 6.00 28.27 150,250 5,310 Type5
1 3 01/01/2008 28 6.00 28.27 143,460 5,070 Type5
Average 5,190
1 4 01/29/2008 56
~~ [2]~ 5l] lSJ DO D
Type 1
Type 2 Type 3 Type 4
Type 5
Type 6
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd.
(TMlKW) Page 1 of 16
Rone Engineering
.
Client:
Duke Construction, LP
14241 Dallas Pkwy, Ste 1000
Dallas, TX 75254-2936
8908 Ambassador Row, Dallas, TX 75241
7701 W Little York, Ste 600, Houston, TX 77040
4421 Freidrich, Ste 195, Austin, TX 78744
Corporate Phone: (214) 630-9745
Report of Concrete Compressive Strength Test
Report No.: 307153
Project No.: 0712932
Date of Service: 12/04/2007
Report Date: 01/04/2008
Project: Hemisphere's at Point West
Coppell, Texas
Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
Contractor: Duke Construction, LP
Concrete Supplier: Potter Concrete
Plant: 10
Specification Requirements
Strength: 4,000 psi @ 28 days
Slump (in.): 4" - 6"
Air (%): 3% - 5%
Test Method: ASTM C-172
ASTM C-31 (except 10.1.2)
ASTM C-143
ASTM C-231
ASTM C-1 064
ASTM C-138
ASTM C-39
PROJECT DATA
Mix Design I.D.: 7753PW
Placement Date: 12/04/2007
Weather Conditions: Clear
Time Sampled: 04:45am
Temperature - Air: 400F
Truck No: 138
Air Content: 4.2%
Overall Placement Location:
Paving
Batch time: 04:23am
Concrete: 800F
Ticket No: 9670
Unit Weight (pct): NA
Measured
Slump
(inches)
5.0
Sample Location:
100' north, 100' east from northwest building corner
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12"
Cylinder Maximum Compressive
Marked Date Age Diameter Area Load Strength Fracture
Set No. Tested (days) (in) (inZ) (Ibs) (psi) Type
2 1 12/11/2007 7 6.00 28.27 100,850 3,570 Type2
2 2 01/01/2008 28 6.00 28.27 151,130 5,350 Type6
2 3 01/01/2008 28 6.00 28.27 143,080 5,060 Type2
Average 5,200
2 4 01/29/2008 56
0~ ~Q] ~ ~ DO D
Type 1
Type 2 Type 3 Type 4
Type 5
Type 6
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd.
(TM/KW) Page 3 of 16
Rone Engineering
.
Client:
Duke Construction, LP
14241 Dallas Pkwy, Ste 1000
Dallas, TX 75254-2936
8908 Ambassador Row, Dallas, TX 75247
7701 W Little York, Ste 600, Houston, TX 77040
4421 Freidrich, Ste 195, Austin, TX 78744
Corporate Phone: (214) 630-9745
Report of Concrete Compressive Strength Test
Report No.: 307153
Project No.: 0712932
Date of Service: 12/04/2007
Report Date: 01/04/2008
Project: Hemisphere's at Point West
Coppell, Texas
Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
Contractor: Duke Construction, LP
Concrete Supplier: Potter Concrete
Plant: 10
Specification Requirements
Strength: 4,000 psi @ 28 days
Slump (in.): 4" - 6"
Air (%): 3% - 5%
Test Method: ASTM C-172
ASTM C-31 (except 10.1.2)
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-138
ASTM C-39
PROJECT DATA
Mix Design I.D.: 7753PW
Placement Date: 12/04/2007
Weather Conditions: Clear
Time Sampled: 05:50am
Temperature - Air: 420F
Truck No: 139
Air Content: 4.0%
Overall Placement Location:
Paving
Batch time: 05:33am
Concrete: 800F
Ticket No: 9685
Unit Weight (pet): NA
Measured
Slump
(inches)
5.75
Sample Location:
125' north, 215' east from northwest building corner
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12"
Cylinder Maximum Compressive
Marked Date Age Diameter Area Load Strength Fracture
Set No. Tested (days) (in) (in') (Ibs) (psi) Type
3 1 12/11/2007 7 6.00 28.27 86,630 3,060 Type2
3 2 01/01/2008 28 6.00 28.27 125,890 4,450 Type6
3 3 01/01/2008 28 6.00 28.27 123,370 4,360 Type6
Average 4,410
3 4 01/29/2008 56
~t3 ~0 fIE bJ DO D
Type 1
Type 2 Type 3 Type 4
Type 5
Type 6
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd.
(TM/KW) Page 5 of 16
Rone Engineering
.
Client:
Duke Construction, LP
14241 Dallas Pkwy, Ste 1000
Dallas, TX 75254-2936
8908 Ambassador Row, Dallas, TX 75247
7701 W Little York, Ste 600, Houston, TX 77040
4421 Freidrlch, Ste 195, Austin, TX 78744
Corporate Phone: (214) 630-9745
Report of Concrete Compressive Strength Test
Report No.: 307153
Project No.: 0712932
Date of Service: 12/04/2007
Report Date: 01/04/2008
Project: Hemisphere's at Point West
Coppell, Texas
Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
Contractor: Duke Construction, LP
Concrete Supplier: Potter Concrete
Plant: 10
Specification Requirements
Strength: 4,000 psi @ 28 days
Slump (in.): 4" - 6"
Air (%): 3% - 5%
Test Method: ASTM C-172
ASTM C-31 (except 10.1.2)
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-138
ASTM C-39
PROJECT DATA
Mix Design 1.0.: 7753PW
Placement Date: 12/04/2007
Weather Conditions: Clear
Time Sampled: 07:00am
Temperature - Air: 450F
Truck No: 110
Air Content: 4.3%
Overall Placement Location:
Paving
Batch time: 06:42am
Concrete: 800F
Ticket No: 9699
Unit Weight (pct): NA
Measured
Slump
(inches)
5.75
Sample Location:
25' north, 300' east from northwest building corner
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12"
Cylinder Maximum Compressive
Marked Date Age Diameter Area Load Strength Fracture
Set No. Tested (days) (in) (in') (Ibs) (psi) Type
4 1 12/11/2007 7 6.00 28.27 90,290 3,190 Type6
4 2 01/01/2008 28 6.00 28.27 125,660 4,440 Type2
4 3 01/01/2008 28 6.00 28.27 123,920 4,380 Type2
Average 4,410
4 4 01/29/2008 56
~E3 ~[g ill] EJ DO D
Type 1
Type 2 Type 3 Type 4
Type 5
Type 6
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd.
(TMfKW) Page 7 of 16
Rone Engineering
.
Client:
Duke Construction, LP
14241 Dallas Pkwy, Ste 1000
Dallas, TX 75254-2936
8908 Ambassador Row, Dallas, TX 75247
7701 W Little York, Ste 600, Houston, TX 77040
4421 Freidrich, Ste 195, Austin, TX 78744
Corporate Phone: (214) 630-9745
Report of Concrete Compressive Strength Test
Report No.: 307153
Project No.: 0712932
Date of Service: 12/04/2007
Report Date: 01/04/2008
Project: Hemisphere's at Point West
Coppell, Texas
Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
Contractor: Duke Construction, LP
Concrete Supplier: Potter Concrete
Plant: 10
Specification Requirements
Strength: 4,000 psi @ 28 days
Slump (in.): 4" - 6"
Air (%): 3% - 5%
Test Method: ASTM C-172
ASTM C-31 (except 10.1.2)
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-138
ASTM C-39
PROJECT DATA
Mix Design I.D.: 7753PW
Placement Date: 12/04/2007
Weather Conditions: Sunny, clear
Time Sampled: 08:55am Batch time: 08:36am
Temperature - Air: 520F Concrete: 820F
Truck No: 103 Ticket No: 9716
Air Content: 4.5% Unit Weight (pet): NA
Overall Placement Location:
Paving
Measured
Slump
(inches)
5.25
Sample Location:
75' north, 375' east from northwest building corner
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12"
Cylinder Maximum Compressive
Marked Date Age Diameter Area Load Strength Fracture
Set No. Tested (days) (in) (inZ) (Ibs) (psi) Type
5 1 12/11/2007 7 6.00 28.27 1 02,430 3,620 Type2
5 2 01/01/2008 28 6.00 28.27 145,330 5,140 Type5
5 3 01/01/2008 28 6.00 28.27 137,030 4,850 Type5
Average 4,990
5 4 01/29/2008 56
~ESJ ~[:g &lJ bJ DO 0
Type 1
Type 2 Type 3 Type 4
Type 5
Type 6
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd.
(TMlKW) Page 9 of 16
Rone Engineering
.
Client:
Duke Construction, LP
14241 Dallas Pkwy, Ste 1000
Dallas, TX 75254-2936
8908 Ambassador Row, Dallas, TX 75247
7701 W Little York, Ste 600, Houston, TX 77040
4421 Freidrich, Ste 195, Austin, TX 78744
Corporate Phone: (214) 630-9745
Report of Concrete Compressive Strength Test
Report No.: 307153
Project No.: 0712932
Date of Service: 12/04/2007
Report Date: 01/04/2008
Project: Hemisphere's at Point West
Coppell, Texas
Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12"
Cylinder Maximum Compressive
Marked Date Age Diameter Area Load Strength
Set No. Tested (days) (in) (in') (Ibs) (psi)
6 1 12/11/2007 7 6.00 28.27 105,910 3,750
6 2 01/01/2008 28 6.00 28.27 150,020 5,310
6 3 01/01/2008 28 6.00 28.27 146,620 5,190
Average 5,250
6 4 01/29/2008 56
Contractor: Duke Construction, LP
Concrete Supplier: Potter Concrete
Plant: 10
Specification Requirements
Strength: 4,000 psi @ 28 days
Slump (in.): 4" - 6"
Air (%): 3% - 5%
Test Method: ASTM C-172
ASTM C-31 (except 10.1.2)
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-138
ASTM C-39
~t3 ~~ ill] [SJ DO D
Type 1
Type 2 Type 3 Type 4
Type 5
PROJECT OAT A
Mix Design 1.0.: 7753PW
Placement Date: 12/04/2007
Weather Conditions: Sunny, clear
Time Sampled: 09:55am Batch time: 09:39am
Temperature - Air: 55DF Concrete: 84DF
Truck No: 139 Ticket No: 9730
Air Content: 4.4% Unit Weight (pet): NA
Overall Placement Location:
Paving
Measured
Slump
(inches)
5.0
Sample Location:
50' north, 450' east from northwest building corner
Fracture
Type
Type6
Type5
Type3
Type 6
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd.
(TM/KW) Page 11 of 16
Rone Engineering
.
Client:
Duke Construction, LP
14241 Dallas Pkwy, Ste 1000
Dallas, TX 75254-2936
8908 Ambassador Row, Dallas, TX 75247
7701 W Little York, Ste 600, Houston, TX 77040
4421 Freidrich, Ste 195, Austin, TX 78744
Corporate Phone: (214) 630-9745
Report of Concrete Compressive Strength Test
Report No.: 307153
Project No.: 0712932
Date of Service: 12/04/2007
Report Date: 01/04/2008
Project: Hemisphere's at Point West
Coppell, Texas
Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12"
Cylinder Maximum Compressive
Marked Date Age Diameter Area Load Strength
Set No. Tested (days) (in) (in') (Ibs) (psi)
7 1 12/11/2007 7 6.00 28.27 116,930 4,140
7 2 01/01/2008 28 6.00 28.27 148,250 5,240
7 3 01/01/2008 28 6.00 28.27 139,430 4,930
Average 5,090
7 4 01/29/2008 56
Contractor: Duke Construction, LP
Concrete Supplier: Potter Concrete
Plant: 10
Specification Requirements
Strength: 4,000 psi @ 28 days
Slump (in.): 4" - 6"
Air (%): 3% - 5%
Test Method: ASTM C-172
ASTM C-31 (except 10.1.2)
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-138
ASTM C-39
0E3 ~[g Brn bJ DO 0
Type 1
Type 2 Type 3 Type 4
Type 5
PROJECT DATA
Mix Design 1.0.: 7753PW
Placement Date: 12/04/2007
Weather Conditions: Sunny, clear
Time Sampled: 11:10am Batch time: 10:48am
Temperature - Air: 580F Concrete: 880F
Truck No: 138 Ticket No: 9744
Air Content: 4.5% Unit Weight (pet): NA
Overall Placement Location:
Paving
Measured
Slump
(inches)
4.75
Sample Location:
100' north, 550' east from northwest building corner
Fracture
Type
Type6
Type2
Type5
Type 6
L1MITA nONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services. Ltd.
(TMlKW) Page 13 of 16
Rone Engineering
.
Client:
Duke Construction, LP
14241 Dallas Pkwy, Ste 1000
Dallas, TX 75254-2936
8908 Ambassador Row, Dallas, TX 75247
7701 W Little York, Ste 600, Houston, TX 77040
4421 Freidrich, Ste 195, Austin, TX 78744
Corporate Phone: (214) 630-9745
Report of Concrete Compressive Strength Test
Report No.: 307153
Project No.: 0712932
Date of Service: 12/04/2007
Report Date: 01/04/2008
Project: Hemisphere's at Point West
Coppell, Texas
Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
Contractor: Duke Construction, LP
Concrete Supplier: Potter Concrete
Plant: 10
Specification Requirements
Strength: 4,000 psi @ 28 days
Slump (in.): 4" - 6"
Air (%): 3% - 5%
Test Method: ASTM C-172
ASTM C-31 (except 10.1.2)
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-138
ASTM C-39
PROJECT DATA
Mix Design 1.0.: 7753PW
Placement Date: 12/04/2007
Weather Conditions: Sunny, clear
Time Sampled: 12:20pm Batch time: 12:06pm
Temperature - Air: 600F Concrete: 860F
Truck No: 138 Ticket No: 9760
Air Content: 4.2% UnitWeight (pcf): NA
Overall Placement Location:
Paving
Measured
Slump
(inches)
4.75
Sample Location:
125' north, 675' east from northwest building corner
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12"
Cylinder Maximum Compressive
Marked Date Age Diameter Area Load Strength Fracture
Set No. Tested (days) (in) (inZ) (Ibs) (psi) Type
8 1 12/11/2007 7 6.00 28.27 112,710 3,990 Type6
8 2 01/01/2008 28 6.00 28.27 141,920 5,020 Type3
8 3 01/01/2008 28 6.00 28.27 137,940 4,880 Type6
Average 4,950
8 4 01/29/2008 56
~EJ ~~ 5IE t] DO 0
Type 1
Type 2 Type 3 Type 4
Type 5
Type 6
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd.
(TM/KW) Page 15 of 16