Duke Lesley 2A-LR080122 Rone Engineering . Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 310502 Project No.: 0712932 Date of Service: 01/11/2008 Report Date: 01/22/2008 Project: Hemisphere's at Point West Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. Contractor: Duke Construction, LP Concrete Supplier: Potter Concrete Plant: 1 Specification Requirements Strength: 3,000 psi @ 28 days Slump (in.): 4" - 6" Air (%): 3% - 5% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 PROJECT DATA Mix Design 1.0.: 7750PW Placement Date: 01/11/2008 Weather Conditions: Sunny, clear Time Sampled: 11 :35am Batch time: 1 0:49am Temperature - Air: 520F Concrete: 680F Truck No: 141 Ticket No: 18355 Air Content: 3.8% Unit Weight (pet): NA Overall Placement Location: Sidewalk at Point West VII, east side of building Measured Slump (inches) 4.5 Sample Location: 20' east, 10' north from southeast building comer REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Fracture Set No. Tested (days) (in) (in') (Ibs) (psi) Type 1 1 01/18/2008 7 6.00 28.27 110,280 3,900 Type5 1 2 02/08/2008 28 1 3 02/08/2008 28 4 03/07/2008 56 Technician: Montreal Bailey Rone Engineering See Report 310431 for technician time~ ~ Report Distribution: ~ Orig: Duke Construction, LP (Dallas, TX) Attn: Mr. Paul Byrne . . .. . .. . · (1-ec copy) 1-cc Potter Concrete Attn: Mr Ryan Skelly K. Scott Watson, AET 1-cc City of Coppell Attn: Mr. Lee Stone Project Manager 1-cc City of Coppell Attn: Mr. Larry Davis 0E3 ~[g fill] t;J DO D Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 ~ LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, ltd. (KWfKW) Page 1 of 1 Rone Engineering . Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 310431 Project No.: 0712932 Date of Service: 01/11/2008 Report Date: 01/22/2008 Project: Hemisphere's at Point West Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA Contractor: Duke Construction, LP Concrete Supplier: Potter Concrete Plant: 1 Specification Requirements Strength: 4,000 psi @28 days Slump (in.): 4" - 6" Air (%): 3% - 5% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 Mix Design I.D.: 7753PW Placement Date: 01/11/2008 Weather Conditions: Clear Time Sampled: 05:00am Temperature - Air: 370F Truck No: 125 Air Content: 4.1 % Overall Placement Location: Paving, 75' away from building on south side from grid line 15-22/L Measured Slump (inches) 4.75 Batch time: 04:41 am Concrete: 500F Ticket No: 18297 Unit Weight (pet): NA Sample Location: Grid line 22/L REPORT OF TESTS Cylinder Marked Date Set No. Tested 1 1 01118/2008 1 2 02/08/2008 1 3 02/08/2008 1 4 03/07/2008 Age (days) 7 Diameter (in) 6.00 28 28 56 ~E:9 ~l9 ~ ~ DO D Type 1 Type 2 Type 3 Type 4 Type 5 Concrete Compressive Cylinder 6" x 12" Maximum Load (Ibs) 119,480 Compressive Strength (psi) 4,230 Fracture Type Type6 Area (inZ) 28.27 Type 6 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (TM/KW) Page 1 of 10 Rone Engineering . Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 310431 Project No.: 0712932 Date of Service: 01/11/2008 Report Date: 01/22/2008 Project: Hemisphere's at Point West Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA Contractor: Duke Construction, LP Concrete Supplier: Potter Concrete Plant: 1 Specification Requirements Strength: 4,000 psi @ 28 days Slump (in.): 4" - 6" Air (%): 3% - 5% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 Mix Design I.D.: 7753PW Placement Date: 01/11/2008 Weather Conditions: Clear Time Sampled: 05:45am Temperature - Air: 370F Truck No: 130 Air Content: 4.3% Overall Placement Location: Paving, 75' away from building on south side from grid line 15-22/L Measured Slump (inches) 4.75 Batch time: 05:30am Concrete: 500F Ticket No: 18307 Unit Weight (pet): NA Sample Location: Grid line U21 REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Fracture Set No. Tested (days) (in) (in') (Ibs) (psi) Type 2 1 01/18/2008 7 6.00 28.27 115,400 4,080 Type2 2 2 02/08/2008 28 2 3 02/08/2008 28 2 4 03/07/2008 56 ~~ ~~ [)ffi ~ DO D Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (TM!KW) Page 2 of 10 Rone En~== Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, 8te 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 310431 Project No.: 0712932 Date of Service: 01/11/2008 Report Date: 01/22/2008 Project: Hemisphere's at Point West Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA Contractor: Duke Construction, LP Concrete Supplier: Potter Concrete Plant: 1 Specification Requirements Strength: 4,000 psi @28 days Slump (in.): 4" - 6" Air (%): 3% - 5% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 Mix Design 1.0.: 7753PW Placement Date: 01/11/2008 Weather Conditions: Clear Time Sampled: 06:40am Temperature - Air: 370F Truck No: 129 Air Content: 4.6% Overall Placement Location: Paving, 75' away from building on south side from grid line 15-22/L Measu red Slump (inches) 5.5 Batch time: 06:30am Concrete: 520F Ticket No: 18320 Unit Weight (pet): NA Sample Location: Grid line U19.5 REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Fracture Set No. Tested (days) (in) (in2) (Ibs) (psi) Type 3 1 01/18/2008 7 6.00 28.27 88,600 3,130 Type6 3 2 02/08/2008 28 3 3 02/08/2008 28 3 4 03/07/2008 56 ~[J ~[JJ [)ru ~ DO D Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing, We assume no responsibility for variation in quality (composition, appearance, etc,) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd, (TMIKW) Page 3 of 10 Rone Engineering . Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 310431 Project No.: 0712932 Date of Service: 01111/2008 Report Date: 01/22/2008 Project: Hemisphere's at Point West Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. Contractor: Duke Construction, LP Concrete Supplir'l!': Potter Concrete Plant: 1 Specification Requirements Strength: 4,000 psi @ 28 days Slump (in.): 4" - 6" Air (%): 3% - 5% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 PROJECT DATA Mix Design I.D.: 7753PW Placement Date: 01/11/2008 Weather Conditions: Sunny, clear Time Sampled: 07:20am Batch time: 06:57am Temperature - Air: 400F Concrete: 520F Truck No: 138 Ticket No: 18326 Air Content: 4.4% Unit Weight (pet): NA Overall Placement Location: Paving, 75' away from building on south side from grid line 15-22/L Measured Slump (Inches) 5.25 Sample Location: Grid lines U18.25 REPORT OF TESTS Cylinder Marked Date Set No. Tested 4 1 01/18/2008 4 2 02/08/2008 4 3 02/08/2008 4 4 03/07/2008 Age (days) 7 Diameter (in) 6.00 28 28 56 ~E3 ~QJ 5IE E;J DO D Type 1 Type 2 Type 3 Type 4 Type 5 Concrete Compressive Cylinder 6" x 12" Maximum Load (Ibs) 99,220 Compressive Strength (psi) 3,510 Fracture Type Type6 Area (in') 28.27 Type 6 LIMITATIONS: The test results presented herein were prepared based upon the specifiC samples provided for lesting. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (TM/KW) Page 5 of 10 Rone Engineering . Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 310431 Project No.: 0712932 Date of Service: 01/11/2008 Report Date: 01/22/2008 Project: Hemisphere's at Point West Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. Contractor: Duke Construction, LP Concrete Supplier: Potter Concrete Plant: 1 Specification Req uirements Strength: 4,000 psi @ 28 days Slump (in.): 4" - 6" Air (%): 3% - 5% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 PROJECT DATA Mix Design I.D.: 7753PW 'Placement Date: 01/11/2008 tNeather Conditions: Sunny, clear Time Sampled: 08:20am Batch time: 08:04am Temperature - Air: 400F Concrete: 540F Truck No: 125 Ticket No: 18339 Air Content: 4.4% Unit Weight (pet): NA Overall Placement Location: Paving, 75' away from building on south side from grid line 15-221L Measured Slump (inches) 5.0 Sample Location: Grid lines U17.5 REPORT OF TESTS Cylinder Marked Date Set No. Tested 5 1 01/18/2008 5 2 02/08/2008 5 3 02/08/2008 5 4 03/07/2008 Age (days) 7 Diameter (in) 6.00 28 28 56 ~r:g ~Q;] [ill] EJ DO D Type 1 Type 2 Type 3 Type 4 Type 5 Concrete Compressive Cylinder 6" x 12" Maximum Load (Ibs) 99,720 Compressive Strength (psi) 3,530 Fracture Type Type6 Area (in2) 28.27 Type 6 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (TMIKW) Page 7 of 10 Rone Engineering . Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 310431 Project No.: 0712932 Date of Service: 01/11/2008 Report Date: 01/22/2008 Project: Hemisphere's at Point West Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. Contractor: Duke Construction, LP Concrete Supplier: Potter Concrete Plant: 1 Specification Requirements Strength: 4,000 psi @ 28 days Slump (in.): 4" - 6" Air (%): 3% - 5% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 PROJECT DATA Mix Design I.D.: 7753PW Placement Date: 01/11/2008 Weather Conditions: Sunny, clear Time Sampled: 09:40am Batch time: 09:15am Temperature - Air: 410F Concrete: 550F Truck No: 138 Ticket No: 18347 Air Content: 4.2% Unit Weight (pet): NA Overall Placement Location: Paving, 75' away from building on south side from grid line 15-22/L Measured Slump (inches) 5.0 Sample Location: Grid lines U15 REPORT OF TESTS Cylinder Marked Date Set No. Tested 6 1 01/18/2008 6 2 02/08/2008 6 3 02/08/2008 6 4 03/07/2008 Age (days) 7 Diameter (in) 6.00 28 28 56 ~E:3 [9]Q] &E lSJ DO D Type 1 Type 2 Type 3 Type 4 Type 5 Concrete Compressive Cylinder 6" x 12" Maximum Load (Ibs) 100,320 Compressive Strength (psi) 3,550 Fracture Type Type5 Area (in') 28.27 Type 6 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (TMlKW) Page 9 of 10