Loading...
Duke Lesley 1A-LR071112 (2) Rone Engine~ring . 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, SOO 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 Report of In-Place Density Testing Report No.: 304821 Project No.: 0713408 Date of Service: 11/08/2007 Report Date: 11/12/2007 Project: Point West VI Coppell, Texas Services: Perform In-Place Density Testing PROJECT DATA Contractor: Duke Construction, LP Test Method: ASTM 0-6938 Gauge: Troxler 3430 Gauge Serial No: 35518 Test Mode: DT Standard Counts Moisture Density Current: 735 Current: 2568 Previous: 730 Previous: 2522 MOISTURE DENSITY RELATIONS Maximum Moisture Density Project Requirements MID No. Description % (pef) Moisture Density 272998 Brown I Silty Clay wI Organics 22.5 96.5 Optimum +4 95min FIELD DENSITY TESTS Test Probe MID Moisture Wet Density Dry Density Density No Test Location Depth No. % (pef) (pef) (%max) Utility backfill 1 60" Storm sewer line H, Station 0+50, 3' below 6" 272998 25.5 115.8 92.3 96 grade Utility backfill 2 60" Storm sewer line H, Station 0+50, l' below 6" 272998 22.8 115.7 94.2 98 grade Utility backfill 3 60" Storm sewer line H, Station 0+50, final 6" 272998 24.7 115.2 92.4 96 Utility backfill 4 60" Storm sewer line H, Station 2+50, 3' below 6" 272998 24.3 114.2 91.9 95 grade Utility backfill 5 60" Storm sewer line H, Station 2+50, l' below 6" 272998 24.8 115.2 92.3 96 grade Utility backfill 6 60" Storm sewer line H, Station 2+50, final 6" 272998 26.0 115.2 91.4 95 Utility backfill 7 Water line W-1, Station 1+25,2' below grade 6" 272998 25.2 115.4 92.2 96 Utility backfill 8 Water line W-1, Station 1 +25, final 6" 272998 25.3 114.8 91.6 95 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (CHfED) Page 1 of 2 Rone Engineering . 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 Report of In-Place Density Testing Report No.: 304821 Project No.: 0713408 Date of Service: 11/08/2007 Report Date: 11/12/2007 Project: Point West VI Coppell, Texas Services: Perform In-Place Density Testing FIELD DENSITY TESTS Test Probe MID Moisture Wet Density Dry Density Density No Test Location Depth No. % (pct) (pct) (% max) Utility backfill 9 Water line W-1, Station 3+25, 2' below grade 6" 272998 22.9 116.4 94.7 98 Utility backfill 10 Water line W-1, Station 3+25, final 6" 272998 23.0 117.5 95.5 99 Utility backfill 11 Water line W-1, Station 6+25, 2' below grade 6" 272998 23.1 117.1 95.1 99 Utility backfill 12 Water line W-1, Station 6+25, final 6" 272998 23.7 116.8 94.4 98 Technician: Joe Jernigan Started: 01 :OOpm Finished: Report Distribution: Orig: Duke Construction, LP (Dallas, TX) Attn: Mr. Emmit Coots (1-ec copy) 1-cc Pacheco Koch Consulting Engineers Altn: Mr. Jack Evans 1-cc City of Coppell Altn: Mr. Larry Davis 1-cc City of Coppell Altn: Mr. Lee Stone 02:30pm Rone Engineering p~-~ K. Scott Watson, AET Project Manager LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (CHIED) Page 2 of 2 Rone Engineering . 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 Report of In-Place Density Testing Report No.: 304664 Project No.: 0713408 Date of Service: 11/07/2007 Report Date: 11/12/2007 Project: Point West VI Coppell, Texas Services: Perform In-Place Density Testing PROJECT DATA Contractor: Duke Construction, LP Test Method: ASTM 0-6938 Gauge: Troxler 3430 Gauge Serial No: 35518 Test Mode: DT Standard Counts Moisture Density Current: 730 Current: 2522 Previous: 742 Previous: 2526 MOISTURE DENSITY RELATIONS MID No. 272998 Description Brown I Silty Clay wI Organics Moisture % Maximum Density ( pet) 96.5 Project Requirements Moisture Density Optimum +4 95 min 22.5 T est Location FIELD DENSITY TESTS Probe MID Depth No. Moisture Wet Density Dry Density Density % (pet) (pet) (% max) Test No Utility backfill Sanitary sewer line 3, 200' from south end, 4' 6" 272998 25.3 114.8 91.6 95 below grade Utility backfill 2 Sanitary sewer line 3, 200' from south end, 2' 6" 272998 25.2 115.4 92.2 96 below grade Utility backfill 3 Sanitary sewer line 3, 200' from south end, final 6" 272998 26.0 115.2 91.4 95 Technician: Joe Jernigan Started: 11 :45am Finished: Report Distribution: Orig: Duke Construction, LP (Dallas, TX) Attn: Mr. Emmit Coots (1-ee copy) 1-cc Pacheco Koch Consulting Engineers Attn: Mr. Jack Evans 1-cc City of Coppell Attn: Mr. Larry Davis 1-ec City of Coppell AUn: Mr. Lee Stone 0145~;;; ~ K. Scott Watson, AET Project Manager LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (CHIED) Page 1 of 1 Rone Engineering . 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 Report of In-Place Density Testing Report No.: 304488 Project No.: 0713408 Date of Service: 11/06/2007 Report Date: 11/12/2007 Project: Point West VI Coppell, Texas Services: Perform In-Place Density Testing PROJECT DATA Contractor: Duke Construction, LP Test Method: ASTM D-6938 Gauge: Troxler 3430 Gauge Serial No: 35518 Test Mode: DT Standard Counts Moisture Density Current: 742 Current: 2526 Previous: 740 Previous: 2541 MOISTURE DENSITY RELATIONS Maximum Moisture Density Project Requirements MID No. Description % (pet) Moisture Density 272998 Brown I Silty Clay wi Organics 22.5 96.5 Optimum +4 95 min FIELD DENSITY TESTS Test Probe MID Moisture Wet Density Dry Density Density No Test Location Depth No. % (pct) (pet) (%max) Utility backfill 1 Storm drain line E, Station 0+50, 4' below grade 6" 272998 22.9 116.4 94.7 98 Utility backfill 2 Storm drain line E, Station 0+50, 2' below grade 6" 272998 23.0 117.5 95.5 99 Utility backfill 3 Storm drain line E, Station 0+50, grade 6" 272998 23.1 117.1 95.1 99 Utility backfill 4 Storm drain line E, Station 2+50, 2' below grade 6" 272998 23.7 116.8 94.4 98 Utility backfill 5 Storm drain line E, Station 2+50, final 6" 272998 23.7 116.3 94.0 97 Technician: Joe Jernigan Report Distribution: Orig: Duke Construction, LP (Dallas, TX) Attn: Mr. Emmit Coots (1-ec copy) 1-cc Pacheco Koch Consulting Engineers Attn: Mr. Jaek Evans 1-cc City of Coppell Attn: Mr. Larry Davis 1-cc City of Coppell Attn: Mr. Lee Stone Started: 01 :15pm Finished: 03:00pm Rone Engineering p~..~ K. Scott Watson, AET Project Manager L1MITA nONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition. appearance, etc.) or any other feature of similar SUbject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (CH/ED) Page 1 of 1 Rone Engineering . 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 Report of In-Place Density Testing Report No.: 304420 Project No.: 0713408 Date of Service: 11/05/2007 Report Date: 11/12/2007 Project: Point West VI Coppell, Texas Services: Perform In-Place Density Testing PROJECT DATA Contractor: Duke Construction, LP Test Method: ASTM 0-6938 Gauge: Troxler 3430 Gauge Serial No: 35518 Test Mode: DT Standard Counts Moisture Density Current: 749 Current: 2528 Previous: 740 Previous: 2521 MOISTURE DENSITY RELATIONS MID No. 272998 Description Brown I Silty Clay wi Organics Moisture % Maximum Density (pct) 96.5 Project Requirements Moisture Density Optimum +4 95 min 22.5 Test No Test Location FIELD DENSITY TESTS Probe MID Depth No. Moisture Wet Density Dry Density Density % (pet) (pct) (% max) Utility backfill Sanitary sewer line 3, 50' from north end, 4' 6" 272998 22.6 116.6 95.1 99 below grade Utility backfill 2 Sanitary sewer line 3,50' from north end, 2' 6" 272998 24.1 116.4 93.8 97 below grade Utility backfill 3 Sanitary sewer line 3, 50' from north end, grade 6" 272998 24.9 116.8 93.5 97 Technician: Joe Jernigan Report Distribution: Orig: Duke Construction, LP (Dallas, TX) Attn: Mr. Emmit Coots (1-ec copy) 1-cc Pacheco Koch Consulting Engineers Attn: Mr. Jack Evans 1-cc City of Coppel! Attn: Mr. Larry Davis 1-cc City of Coppell Attn: Mr. Lee Stone Started: 12:30pm Finished: 02:15pm Rone Engineering ,~~ K. Scott Watson, AET Project Manager LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (CH/ED) Page 1 of 1 Rone Engineering . 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 Report of In-Place Density Testing Report No.: 304005 Project No.: 0713408 Date of Service: 11/01/2007 Report Date: 11/12/2007 Project: Point West VI Coppell, Texas Services: Perform In-Place Density Testing PROJECT DATA Contractor: Duke Construction, LP Test Method: ASTM D-6938 Gauge: Troxler 3430 Gauge Serial No: 35518 Test Mode: DT Standard Counts Moisture Density Current: 749 Current: 2528 Previous: 744 Previous: 2563 MOISTURE DENSITY RELATIONS MID No. 299552 272998 Description Lime Treated Brown & Tan I Sandy Clay Brown I Silty Clay wI Organics Moisture % Maximum Density (pet) 85.7 96.5 Project Requirements Moisture Density Optimum +4 95 min Optimum +4 95 min 30.3 22.5 FIELD DENSITY TESTS Test Probe MID Moisture Wet Density Dry Density Density No Test Location Depth No. % (pet) (pet) (% max) Subgrade Building pad, grid lines A.5/40 6" 299552 33.8 111.7 83.5 97 Subgrade 2 Building pad, grid lines C.5/40 6" 299552 33.7 111.8 83.6 98 Subgrade 3 Building pad, grid lines E.5/40 6" 299552 31.1 111.3 84.9 99 Subgrade 4 Building pad, grid lines G.5/40 6" 299552 32.6 111.1 83.8 98 Subgrade 5 Building pad, grid lines J.5/40 6" 299552 30.7 111.0 84.9 99 Utility backfill 6 Sanitary sewer line 1, 100' from north end, 6' 6" 272998 24.1 117.5 94.7 98 below grade Utility backfill 7 Sanitary sewer line 1, 100' from north end, 4' 6" 272998 22.7 117.4 95.7 99 below grade Utility backfill 8 Sanitary sewer line 1, 100' from north end, 2' 6" 272998 24.2 117.1 94.3 98 below grade LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (CH/ED) Page 1 of 2 Rone Engineering . 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 Report of In-Place Density Testing Report No.: 304005 Project No.: 0713408 Date of Service: 11/01/2007 Report Date: 11/12/2007 Project: Point West VI Coppell, Texas Services: Perform In-Place Density Testing FIELD DENSITY TESTS Test Probe MID Moisture Wet Density Dry Density Density No Test Location Depth No. % (pet) (pet) (% max) Utility backfill 9 Sanitary sewer line 1, 100' from north end, final 6" 272998 24.8 116.9 93.7 97 Technician: Joe Jernigan Started: 01 :OOpm Finished: Report Distribution: Orig: Duke Construction, LP (Dallas, TX) Attn: Mr. Emmit Coots (1-ec copy) 1-cc Pacheco Koch Consulting Engineers Attn: Mr. Jack Evans 1-cc City of Coppell Attn: Mr. Larry Davis 1-cc City of Coppell Attn: Mr. Lee Stone 02:30pm Rone Engineering p~~ K. Scott Watson, AET Project Manager LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (CH/ED) Page 2 of 2