Duke Lesley 1A-LR080121
Rone Engineering
.
8908 Ambassador Row, Dallas, TX 75247
7701 W Little York, Ste 600, Houston, TX 77040
4421 Freidrich, Ste 195, Austin, TX 78744
Corporate Phone: (214) 630-9745
Client:
Duke Construction, LP
14241 Dallas Pkwy, Ste 1000
Dallas, TX 75254-2936
Report of Reinforcing Steel Inspection
Report No.: 310818
Project No.: 0713408
Date of Service: 01/15/2008
Report Date: 01/21/2008
Project: Point West VI
Coppell, Texas
Services: Reinforcing Steel Inspection
Report of Inspection
Locations and Items Inspected:
Paving from building 100' north (width) - 650' west from northeast ramp west,
to 1100' west of northeast ramp
"em s Inspected: Co nfo rm ing Non Items Inspected: Confonming Non Items Inspected: Confonming Non
Co nforming Co nfo rm ing Conforming
P lacing Drawings Bar length Column Ties Properly
Approved x and Shape x Tied and Spaced N/A
Bar Size x Pro per B ar P lacem ent x Stirrup Spacing N/A
Bar Grade x Pro perly Tied x Stirrup Type NIA
Bars Clean x Dowel Bars in Place x lapped Splices x
Form Ciean x Pro per B ar Suppo rts x Corner Bars x
Number of Bars x Proper Cover x II! echanical Splices N/A
Discrepancies I Comments: No discrepancies noted.
Technician: Dane Campbell Started: 01 :OOpm
Report Distribution:
Orig: Duke Construction, LP (Dallas, TX)
Attn: Mr. Emmit Coots (1-ec copy)
1-cc Duke Construction, LP Attn: Mr. Emmit Coots
1-cc City of Coppell Attn: Mr. Lee Stone
1-cc City of Coppell Attn: Mr. Larry Davis
1-cc Pacheco Koch Consulting Engineers Attn: Mr. Jack Evans
Finished:
w~~
K. Scott Watson, AET
Project Manager
~
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd.
(CH/KW) Page 1 of 1
Rone Engineering
.
8908 Ambassador Row, Dallas, TX 75247
7701 W Little York, Ste 600, Houston, TX 77040
4421 Freidrich, Ste 195, Austin, TX 78744
Corporate Phone: (214) 630-9745
Client:
Duke Construction, LP
14241 Dallas Pkwy, Ste 1000
Dallas, TX 75254-2936
Report of Reinforcing Steel Inspection
Report No.: 310681
Project No.: 0713408
Date of Service: 01/14/2008
Report Date: 01/21/2008
Project: Point West VI
Coppell, Texas
Services: Reinforcing Steel Inspection
Report of Inspection
Locations and Items Inspected:
Fire lane pavinl on north and south side of building
Items Inspected: Conforming Non Items Inspected: Conforming Non Items Inspected: Co nfo rm ing Non
Co nfo rm ing Conforming Conforming
Placing Drawings Bar Length Column Ties Properly
Appro ved x and Shape x Tied and Spaced N/A
BarSize x Proper Bar Placement x Stirrup Spacing N/A
Bar Grade x Properly Tied Note 1 Stirrup Type N/A
Bars Clean x Dowel Bars in Place Note 2 Lapped Splices x
Form Clean x Pro per B ar Suppo rts x CornerBars N/A
Num ber of Bars x ProperCover x Mechanical Splices N/A
Discrepancies I Comments:
Note 1: Tied down rebar at various locations
Note 2: Adjust dowel bars
The discrepancies noted above were corrected at the time of inspection.
Technician: Jose Villanueva Started: 03:15pm
Report Distribution:
Orig: Duke Construction, LP (Dallas, TX)
Attn: Mr. Emmit Coots (1-ec copy)
1-cc Duke Construction, LP Attn: Mr. Emmit Coots
1-cc City of Coppell Attn: Mr. Lee Stone
1-cc City of Coppell Attn: Mr. Larry Davis
1-cc Pacheco Koch Consulting Engineers Attn: Mr. Jack Evans
Finished: 04:30pm Rone Engineering
p~~
K. Scott Watson, AET
Project Manager
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance. etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd.
(CH/KW) Page 1 of 1