Loading...
Duke Lesley 1A-LR080121 Rone Engineering . 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 Report of Reinforcing Steel Inspection Report No.: 310818 Project No.: 0713408 Date of Service: 01/15/2008 Report Date: 01/21/2008 Project: Point West VI Coppell, Texas Services: Reinforcing Steel Inspection Report of Inspection Locations and Items Inspected: Paving from building 100' north (width) - 650' west from northeast ramp west, to 1100' west of northeast ramp "em s Inspected: Co nfo rm ing Non Items Inspected: Confonming Non Items Inspected: Confonming Non Co nforming Co nfo rm ing Conforming P lacing Drawings Bar length Column Ties Properly Approved x and Shape x Tied and Spaced N/A Bar Size x Pro per B ar P lacem ent x Stirrup Spacing N/A Bar Grade x Pro perly Tied x Stirrup Type NIA Bars Clean x Dowel Bars in Place x lapped Splices x Form Ciean x Pro per B ar Suppo rts x Corner Bars x Number of Bars x Proper Cover x II! echanical Splices N/A Discrepancies I Comments: No discrepancies noted. Technician: Dane Campbell Started: 01 :OOpm Report Distribution: Orig: Duke Construction, LP (Dallas, TX) Attn: Mr. Emmit Coots (1-ec copy) 1-cc Duke Construction, LP Attn: Mr. Emmit Coots 1-cc City of Coppell Attn: Mr. Lee Stone 1-cc City of Coppell Attn: Mr. Larry Davis 1-cc Pacheco Koch Consulting Engineers Attn: Mr. Jack Evans Finished: w~~ K. Scott Watson, AET Project Manager ~ LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (CH/KW) Page 1 of 1 Rone Engineering . 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 Report of Reinforcing Steel Inspection Report No.: 310681 Project No.: 0713408 Date of Service: 01/14/2008 Report Date: 01/21/2008 Project: Point West VI Coppell, Texas Services: Reinforcing Steel Inspection Report of Inspection Locations and Items Inspected: Fire lane pavinl on north and south side of building Items Inspected: Conforming Non Items Inspected: Conforming Non Items Inspected: Co nfo rm ing Non Co nfo rm ing Conforming Conforming Placing Drawings Bar Length Column Ties Properly Appro ved x and Shape x Tied and Spaced N/A BarSize x Proper Bar Placement x Stirrup Spacing N/A Bar Grade x Properly Tied Note 1 Stirrup Type N/A Bars Clean x Dowel Bars in Place Note 2 Lapped Splices x Form Clean x Pro per B ar Suppo rts x CornerBars N/A Num ber of Bars x ProperCover x Mechanical Splices N/A Discrepancies I Comments: Note 1: Tied down rebar at various locations Note 2: Adjust dowel bars The discrepancies noted above were corrected at the time of inspection. Technician: Jose Villanueva Started: 03:15pm Report Distribution: Orig: Duke Construction, LP (Dallas, TX) Attn: Mr. Emmit Coots (1-ec copy) 1-cc Duke Construction, LP Attn: Mr. Emmit Coots 1-cc City of Coppell Attn: Mr. Lee Stone 1-cc City of Coppell Attn: Mr. Larry Davis 1-cc Pacheco Koch Consulting Engineers Attn: Mr. Jack Evans Finished: 04:30pm Rone Engineering p~~ K. Scott Watson, AET Project Manager LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance. etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (CH/KW) Page 1 of 1