Duke Lesley 1A-LR080122 Rone Engineering . Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, 8te 600, Houston, TX 77040 4421 Freidrich, 8te 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 310619 Project No.: 0713408 Date of Service: 01/14/2008 Report Date: 01/22/2008 Project: Point West VI Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA Contractor: Duke Construction, LP Concr"tte Supplier: Potter Concrete Plant: 1 Specification Requirements Strength: 4,000 psi @ 28 days Slump (in.): 3" - 5" Air (%): 3% - 5% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 Mix Design 1.0.: 7753PW6 Placement Date: 01/14/2008 Weather Conditions: Clear Time Sampled: 03:20am Temperature - Air: 400F Truck No: 133 Air Content: 4.6% Overall Placement Location: Parking lot, paving, north side of building 6 Sample Location: 10' west from northwest corner of building 6 REPORT OF TESTS Batch time: 03:03am Concrete: 550F Ticket No: 18379 Unit Weight (pet): NA Measured Slump (inches) 5.0 Cylinder Marked Date Set No. Tested 1 1 01/21/2008 1 2 02/11/2008 1 3 02/11/2008 4 03/10/2008 Age (days) 7 Diameter (in) 6.00 28 28 56 ~EJ ~~ ~ tJ DO D Type 1 Type 2 Type 3 Type 4 Type 5 Concrete Compressive Cylinder 6" x 12" Maximum Load (Ibs) 113,440 Area (in') 28.27 Type 6 Compressive Strength (psi) 4,010 Fracture Type Type2 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (TMlKW) Page 1 of 19 Rone Engineering . Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste &00, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) &30-9745 Report of Concrete Compressive Strength Test Report No.: 310619 Project No.: 0713408 Date of Service: 01/14/2008 Report Date: 01/22/2008 Project: Point West VI Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA Contractor: Duke Construction, LP Concrete Supplier: Potter Concrete Plant: 1 Specification Req uirements Strength: 4,000 psi @ 28 days Slump (in.): 3" - 5" Air (%): 3% - 5% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 Mix Design I.D.: 7753PW6 Placement Date: 01/14/2008 Weather Conditions: Clear Time Sampled: 03:50am Temperature - Air: 400F Truck No: 103 Air Content: 4.3% Overall Placement Location: Parking lot, paving, north side of building 6 Sample Location: 25' west from northwest corner of building 6 REPORT OF TESTS Batch time: 03:32am Concrete: 540F Ticket No: 18379 Unit Weight (pet): NA Measured Slump (inches) 5.0 Cylinder Marked Date Set No. Tested 2 1 01/21/2008 2 2 02/11/2008 2 3 02/11/2008 2 4 03/10/2008 Age (days) 7 Diameter (in) 6.00 28 28 56 ~~ ~[g [ill] t] DO D Type 1 Type 2 Type 3 Type 4 Type 5 Concrete Compressive Cylinder 6" x 12" Maximum Load (Ibs) 111,950 Area (in2) 28.27 Type 6 Compressive Strength (psi) 3,960 Fracture Type Type2 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance. etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (TMIKW) Page 3 of 19 Rone Engineering . Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 310619 Project No.: 0713408 Date of Service: 01/14/2008 Report Date: 01/22/2008 Project: Point West VI Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA Contractor: Duke Construction, LP Concrete Supplier: Potter Concrete Plant: 1 Specification Requirements Strength: 4,000 psi @ 28 days Slump (in.): 3" - 5" Air (%): 3% - 5% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 Mix Design 1.0.: 7753PW6 Placement Date: 01/14/2008 Weather Conditions: Cledr Time Sampled: 04:48am Temperature - Air: 410F Truck No: 138 Air Content: 4.5% Overall Placement Location: Parking lot, paving, north side of building 6 Sample Location: 90' west from northwest corner of building 6 REPORT OF TESTS Batch time: 04:38am Concrete: 560F Ticket No: 18392 Unit Weight (pct): NA Measured Slump (inches) 5.5 Cylinder Marked Date Set No. Tested 3 1 01/21/2008 3 2 02/11/2008 3 3 02/11/2008 3 4 03/10/2008 Age (days) 7 Diameter (in) 6.00 28 28 56 0E3 ~~ [ill] t] DO D Type 1 Type 2 Type 3 Type 4 Type 5 Concrete Compressive Cylinder 6" x 12" Maximum Load (Ibs) 98,810 Area (in') 28.27 Type 6 Compressive Strength (psi) 3,490 Fracture Type Type5 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (TMIKW) Page 5 of 19 Rone Engineering . Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 8908 Ambassatlor Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freitlrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 310619 Project No.: 0713408 Date of Service: 01/14/2008 Report Date: 01/22/2008 Project: Point West VI Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA Contractor: Duke Construction, LP Concrete Su,...plier: Potter Concrete Plant: 1 Specification Requirements Strength: 4,000 psi @ 28 days Slump (in.): 3" - 5" Air (%): 3% - 5% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 Mix Design I.D.: 7753PW6 Placement Date: 01/14/2008 Weather Conditions: Clear Time Sampled: 05:50am Temperature-Air: 410F Truck No: 135 Air Content: 4.2% Overall Placement Location: Parking lot, paving, north side of building 6 Measured Slump (Iilches) 5.0 Batch time: 05:32am Concrete: 570F Ticket No: 18405 Unit Weight (pct): NA Sample Location: 180' west from northwest corner of building 6 REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Fracture Set No. Tested (days) (in) (in') (Ibs) (psi) Type 4 1 01/21/2008 7 6.00 28.27 102,810 3,640 Type2 4 2 02/11/2008 28 4 3 02/11/2008 28 4 4 03/10/2008 56 ~LJ ~~ ~ E] DO D Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (TMfKW) Page 7 of 19 Rone Engineering . Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214)630-9745 Report of Concrete Compressive Strength Test Report No.: 310619 Project No.: 0713408 Date of Service: 01/14/2008 Report Date: 01/22/2008 Project: Point West VI Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA Contractor: Duke Construction, LP Concrete Supplier: Potter Concrete Plant: 1 Specification Requirements Strength: 4,000 psi @ 28 days Slump (in.): 3" - 5" Air (%): 3% - 5% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1 064 ASTM C-138 ASTM C-39 Mix Design I.D.: 7753PW6 Placement Date: 01/14/2008 Weather Conditions: Sunny Time Sampled: 06:43am Temperature - Air: 350F Truck No: 133 Air Content: 4.2% Overall Placement Location: Parking lot, paving, north side of building 6 Measured Slump (inches) 5.5 Batch time: 06:20am Concrete: 520F Ticket No: 18417 Unit Weight (pet): NA Sample Location: 210' west from northwest corner of building 6 REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Fracture Set No. Tested (days) (in) (in2) (Ibs) (psi) Type 5 1 01/21/2008 7 6.00 28.27 109,850 3,890 Type6 5 2 02/11/2008 28 5 3 02/11/2008 28 5 4 03/10/2008 56 ~rl ~0 ~ ~ DO D Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (TMlKW) Page 9 of 19 Rone Engineering . Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 310619 Project No.: 0713408 Date of Service: 01/14/2008 Report Date: 01/22/2008 Project: Point West VI Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA Contractor: Duke Construction, LP Concrete Supplier: Potter Concrete Plant: 1 Specification Requirements Strength: 4,000 psi @ 28 days Slump (in.): 3" - 5" Air (%): 3% - 5% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 Mix Design 1.0.: 7753PW6 Placement Date: 01/14/21"'08 Weather Conditions: Sunny Time Sampled: 07:28am Temperature - Air: 380F Truck No: 133 Air Content: 4.8% Overall Placement Location: Parking lot, paving, north side of building 6 Measured Slump (inches) 5.5 Batch time: 06:54am Concrete: 540F Ticket No: 18425 Unit Weight (pet): NA Sample Location: 270' west from northwest corner of building 6 REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Fracture Set No. Tested (days) (in) (in') (Ibs) (psi) Type 6 1 01/21/2008 7 6.00 28.27 119,610 4,230 Type2 6 2 02/11/2008 28 6 3 02/11/2008 28 6 4 03/10/2008 56 Br3 ~~ [ill] E] DO D Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (TM/KW) Page 11 of 19 Rone Engineering . Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 310619 Project No.: 0713408 Date of Service: 01/14/2008 Report Date: 01/22/2008 Project: Point West VI Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA Contractor: Duke Construction, LP Concrete Supplier~ Potter Concrete Plant: 1 Specification Requirements Strength: 4,000 psi @ 28 days Slump (in.): 3" - 5" Air (%): 3% - 5% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 Mix Design I.D.: 7753PW6 Placement Date: 01/14/2008 Weather Conditions: Sunny Time Sampled: 08:35am Temperature - Air: 440F Truck No: 103 Air Content: 4.5% Overall Placement Location: Parking lot, paving, north side of building 6 Measured Slulr'P (inch us) 5.0 Batch time: 08: 11 am Concrete: 540F Ticket No: 18434 Unit Weight (pet): NA Sample Location: 330' west from northwest corner of building 6 REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Fracture Set No. Tested (days) (in) (in2) (Ibs) (psi) Type 7 1 01/21/2008 7 6.00 28.27 104,110 3,680 Type2 7 2 02/11/2008 28 7 3 02/11/2008 28 7 4 03/10/2008 56 ~r3 ~g] 5IE ~ DO D Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (TMlKW) Page 13 of 19 Rone Engineering . Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 310619 Project No.: 0713408 Date of Service: 01/14/2008 Report Date: 01/22/2008 Project: Point West VI Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA Contractor: Duke Construction, LP Concrete Supplier: Potter Concrete Plant: 1 Specification Requirements Strength: 4,000 psi @28 days Slump (in.): 3" - 5" Air (%): 3% - 5% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 Mix Design I.D.: 7753PW6 Placement Date: 01/14/2008 Weather Conditions: Sunny Time Sampled: 09:30am Temperature - Air: 440F Truck No: 126 Air Content: 4.6% Overall Placement Location: Parking lot, paving, north side of building 6 Measured Slump (inches) 5.5 Batch time: 08:55am Concrete: 540F Ticket No: 18443 Unit Weight (pet): NA Sample Location: 420' west from northwest corner of building 6 REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Fracture Set No. Tested (days) (in) (in') (Ibs) (psi) Type 8 1 01/21/2008 7 6.00 28.27 109,680 3,880 Type2 8 2 02/11/2008 28 8 3 02/11/2008 28 8 4 03/10/2008 56 0[3 ~~ 5IE lS] DO D Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, LId. (TMlKW) Page 15 of 19 Rone Engineering . Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214)630-9745 Report of Concrete Compressive Strength Test Report No.: 310619 Project No.: 0713408 Date of Service: 01/14/2008 Report Date: 01/22/2008 Project: Point West VI Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA Contractor: Duke Construction, LP Concrete Supplier: Potter Conc"~ete Plant: 1 Specification Requirements Strength: 4,000 psi @ 28 days Slump (in.): 3" - 5" Air (%}: 3% - 5% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 Mix Design 1.0.: 7753PW6 Placement Date: 01/14/2008 Weather Conditions: Sunny Time Sampled: 10:30am Temperature - Air: 490F Truck No: 126 Air Content: 4.6% Overall Placement Location: Parking lot, paving, north side of building 6 Sample Location: 460' west from northwest corner of building 6 REPORT OF TESTS Batch time: 09:54am Concrete: 530F Ticket No: 18451 Unit Weight (pct): NA Measured Slump (inches) 5.0 Cylinder Marked Date Set No. Tested 9 1 01/21/2008 9 2 02/11/2008 9 3 02/11/2008 9 4 03/10/2008 Age (days) 7 Diameter (in) 6.00 28 28 56 ~Ej ~Q] ~ lSJ DO D Type 1 Type 2 Type 3 Type 4 Type 5 Concrete Compressive Cylinder 6" x 12" Maximum Load (Ibs) 97,060 Area (in2) 28.27 Type 6 Compressive Strength (psi) 3,430 Fracture Type Type2 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (TM/KW) Page 17 of 19 Rone En~== Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630.9745 Report of Concrete Compressive Strength Test Report No.: 308783 Project No.: 0713408 Date of Service: 12/21/2007 Report Date: 01/22/2008 Project: Point West VI Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA Contractor: Duke Construction, LP Concrete Supplier: Potter Concrete Plant: On site Specification Requirements Strength: 4,000 psi @ 28 days Slump (in.): 4" - 6" Air (%): 4% - 6% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 Batch time: Concrete: 550F Ticket No: NA Unit Weight (pet): NA Measured Slump (inches) 5.0 Mix Design I.D.: 7753 Placeml9nt Date: 12/21/2007 Weather Conditions: Clear Time Sampled: 03: 15am Temperature - Air: 400F Truck No: 142 Air Content: 4.5% Overall Placement Location: Paving - parking spaces and driveway on north side of building and northwest corner Sample Location: 160' north from grid line A/17.3 REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Fracture Set No. Tested (days) (in) (in') (Ibs) (psi) Type 1 1 12/28/2007 7 6.00 28.27 116,470 4,120 Type2 1 2 01/18/2008 28 6.00 28.27 154,560 5,470 Type2 1 3 01/18/2008 28 6.00 28.27 165,710 5,860 Type2 Average 5,660 1 4 02/15/2008 56 0EJ ~Q] ffi] E;J DO D Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no nesponsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addnessed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (KW/KW) Page 1 of 10 Rone Engineering . Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 308783 Project No.~ 0713408 Date of Service: 12/21/2007 Report Date: 01/22/2008 Project: Point West VI Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Set No. Tested (days) (in) (in') (Ibs) (psi) 2 1 12/28/2007 7 6.00 28.27 105,570 3,730 2 2 01/18/2008 28 6.00 28.27 147,850 5,230 2 3 01/18/2008 28 6.00 28.27 146,070 5,170 Average 5,200 2 4 02/15/2008 56 Contractor: Duke Construction, LP Concrete Supplier: Potter Concrete Plant: On site Specification Requirements Strength: 4,000 psi @ 28 days Slump (in.): 4" - 6" Air (%): 4% - 6% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 ~tj ~[!J ~ ~ DO D Type 1 Type 2 Type 3 Type 4 Type 5 PROJECT DATA Batch time: Concrete: 520F Ticket No: NA Unit Weight (pet): NA Measured Slump (inches) 5.75 Mix Design I.D.: 7753 Placement Date: 12/21/2007 Weather Conditions: Chlar Time Sampled: 05:15am Temperature - Air: 420F Truck No: 137 Air Content: 4.7% Overall Placement Location: Paving - parking spaces and driveway on north side of building and northwest corner Sample Location: 120' north from grid line N16.3 Fracture Type Type5 Type3 Type3 Type 6 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (KW/KW) Page 2 of 10 Rone Engineering . Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freldrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 308783 Project No.: 0713408 Date of Service: 12/21/2007 Report Date: 01/22/2008 Project: Point West VI Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Set No. Tested (days) (in) (in') (Ibs) (psi) 3 1 12/28/2007 7 6.00 28.27 95,890 3,390 3 2 01/18/2008 28 6.00 28.27 132,310 4,680 3 3 01/18/2008 28 6.00 28.27 135,680 4,800 Average 4,740 3 4 02/15/2008 56 Contractor: Duke Construction, LP Concrete Supplier: Potter Concrete Plant: On site Specification Requirements Strength: 4,000 psi @ 28 days Slump (in.): 4" - 6" Air (%): 4% - 6% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 ~r3 ~~ &E ~ DO D Type 1 Type 2 Type 3 Type 4 Type 5 Measured Slump (1Ilches) 5.25 Mix Design 1.0.: 7753 Placement Date: 12/21/2007 Weather Conditions: Clear, windy Time Sampled: 07:00am Batch time: Temperature - Air: 550F Concrete: 580F Truck No: 136 Ticket No: NA Air Content: 5.7% Unit Weight (pet): NA Overall Placement Location: Paving - parking spaces and driveway on north side of building and northwest corner Sample Location: 100' north from grid line A/6.3 Fracture Type Type5 Type2 Type5 Type 6 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (KW/KW) Page 4 of 10 Rone Engineering . Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 308783 Project No.: 0713408 Date of Service: 12/21/2007 Report Date: 01/22/2008 Project: Point West VI Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Set No. Tested (days) (in) (in') (Ibs) (psi) 4 1 12/28/2007 7 6.00 28.27 95,130 3,360 4 2 01/18/2008 28 6.00 28.27 121,440 4,300 4 3 01/18/2008 28 6.00 28.27 116,560 4,120 Average 4,210 4 4 02/15/2008 56 Contractor: Duke Construction, LP Concrete Supplier: Potter Concrete Plant: On site Specification Requirements Strength: 4,000 psi @ 28 days Slump (in.): 4" - 6" Air (%): 4% - 6% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 ~r3 ~l9 Brn ~ DO D Type 1 Type 2 Type 3 Type 4 Type 5 Measured Slump (inches) 5.5 Mix Design 1.0.: 7753 Placement Date: 12/21/2007 Weather Conditions: Clear, windy Time Sampled: 08:34am Batch time: Temperature - Air: 450F Concrete: 550F Truck No: 137 Ticket No: NA Air Content: 5.5% Unit Weight (pet): NA Overall Placement Location: Paving - parking spaces and driveway on north side of building and northwest corner Sample Location: 160' north from grid line A/4.7 Fracture Type Type5 Type6 Type2 Type 6 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (KW/KW) Page 6 of 10 Rone Engineering . Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 308783 Project No.: 0713408 Date of Service: 12/21/2007 Report Date: 01/22/2008 Project: Point West VI Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Set No. Tested (days) (in) (in') (Ibs) (psi) 5 1 12/28/2007 7 6.00 28.27 91,510 3,240 5 2 01/18/2008 28 6.00 28.27 126,890 4,490 5 3 01/18/2008 28 6.00 28.27 116,720 4,130 Average 4,310 5 4 02/15/2008 56 Contractor: Duke Construction, LP Concrete Supplier: Potter Concrete Plant: On site Specification Requirements Strength: 4,000 psi @ 28 days Slump (in.): 4" - 6" Air (%): 4% - 6% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 ~E3 ~Q] Krn ~ DO D Type 1 Type 2 Type 3 Type 4 Type 5 Measured Slump (inches) 5.25 Mix Design 1.0.: 7753 Placement Date: 12/21/2007 Weather Conditions: Clear, windy Time Sampled: Batch time: Temperature - Air: 550F Concrete: 580F Truck No: 137 Ticket No: NA Air Content: 5.7% Unit Weight (pet): NA Overall Placement Location: Paving - parking spaces and driveway on north side of building and northwest corner Sample Location: 120' north from g rid line A/1. 7 Fracture Type Type2 Type2 Type6 Type 6 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (KW/KW) Page 8 of 10 Rone Engineering . Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 308783 Project No.: 0713408 Date of Service: 12/21/2007 Report Date: 01/22/2008 Project: Point West VI Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Set No. Tested (days) (in) (in') (Ibs) (psi) 6 1 12/28/2007 7 6.00 28.27 103,130 3,650 6 2 01/18/2008 28 6.00 28.27 153,740 5,440 6 3 01/18/2008 28 6.00 28.27 150,060 5,310 Average 5,370 6 4 02/15/2008 56 Contractor: Duke Construction, LP Concrete SUPf lier: Potter Concrete F lant: On site Specification Requirements Strength: 4,000 psi @ 28 days Slump (in.): 4" - 6" Air (%): 4% - 6% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 ~E3 ~[g ~ fJ DO D Type 1 Type 2 Type 3 Type 4 Type 5 Measured Slump (inches) 6.0 Mix Design I.D.: 7753 Placement Date: 12/21/2007 Weather Conditions: Sunny, windy Time Sampled: 11 :04am Batch time: Temperature - Air: GOOF Concrete: 580F Truck No: 129 Ticket No: NA Air Content: 5.6% Unit Weight (pet): NA Overall Placement Location: Paving - parking spaces and driveway on north side of building and northwest comer Sample Location: 120' north, 70' west from grid line A/1 Fracture Type Type6 Type3 Type3 Type 6 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance. etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (KWIKW) Page 9 of 10 Rone Engineering . Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (2141630-9745 Report of Concrete Compressive Strength Test Report No.: 308966 Project No.: 0713408 Date of Service: 12/22/2007 Report Date: 01/22/2008 Project: Point West VI Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. Contractor: Duke Construction, LP Concrete Supplier: Potter Concrete Plant: On site Specification Requirements Strength: 4,000 psi @ 28 days Slump (in.): 4" - 6" Air (%): 4% - 6% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 PROJECT DATA Mix Design 1.0.: 7753 Placement Date: 12/22''!007 Weather Conditions: Clear Time Sampled: 03:30am Temperature - Air: 550F Truck No: 109 Air Content: 5.8% Overall Placement Location: Paving, driveway, east side of project Batch time: Concrete: 580F Ticket No: NA Unit Weight (pct): NA Measured Slump (inches) 5.0 Sample Location: 100' north, 30' east from grid lines A/42 REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Fracture Set No. Tested (days) (in) (in') (Ibs) (psi) Type 1 1 12/29/2007 7 6.00 28.27 116,140 4,110 Type2 1 2 01/19/2008 28 6.00 28.27 159,790 5,650 Type2 1 3 01/19/2008 28 6.00 28.27 148,900 5,270 Type2 Average 5,460 1 4 02/16/2008 56 ~EJ ~Q] Krn [;] DO D Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (KW/KW) Page 1 of 10 Rone Engineering . Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 308966 Project No.: 0713408 Date of Service: 12/22/2007 Report Date: 01/22/2008 Project: Point West VI Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Set No. Tested (days) (in) (in2) (Ibs) (psi) 2 1 12/29/2007 7 6.00 28.27 118,270 4,180 2 2 01/19/2008 28 6.00 28.27 163,960 5,800 2 3 01/19/2008 28 6.00 28.27 165,640 5,860 Average 5,830 2 4 02/16/2008 56 Contractor: Duke Construction, LP Concrete Supplier: Potter Concrete Plant: On site Specification Requirements Strength: 4,000 psi @ 28 days Slump (in.): 4" - 6" Air (%): 4% - 6% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 ~E:j ~~ ~ E;J DO D Type 1 Type 2 Type 3 Type 4 Type 5 rROJEf;T DATA Mix Design I.D.: 7753 Placement Date: 12/22/2007 Weather Conditions: Clear Time Sampled: 04:57am Temperature - Air: 570F Truck No: 136 Air Content: 5.7% Overall Placement Location: Paving, driveway, east side of project Batch time: Concrete: 580F Ticket No: NA Unit Weight (pet): NA Measured Slump (inches) 5.75 Sample Location: 55' east from northeast corner of building, grid line A.5/42 Fracture Type Type2 Type6 Type6 Type 6 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (KW/KW) Page 2 of 10 Rone Engineering . Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214)630-9745 Report of Concrete Compressive Strength Test Report No.: 308966 Project No.: 0713408 Date of Service: 12/22/2007 Report Date: 01/22/2008 Project: Point West VI Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Set No. Tested (days) (in) (in2) (Ibs) (psi) 3 1 12/29/2007 7 6.00 28.27 118,490 4,190 3 2 01/19/2008 28 6.00 28.27 170,370 6,030 3 3 01/19/2008 28 6.00 28.27 171,860 6,080 Average 6,050 3 4 02/16/2008 56 Contractor: Duke Construction, LP Concrete Supplier: Potter Concrete Plant: On site Specification Requirements Strength: 4,000 psi @28 days Slump (in.): 4" - 6" Air (%): 4% - 6% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 ~t:J ~~ ~ ~ DO D Type 1 Type 2 Type 3 Type 4 Type 5 PROJECT DATA Mix Design 1.0.: 7753 Placement Date: 12/22/2007 Weather Conditions: Clear Time Sampled: 06:00am Temperature - Air: 530F Truck No: 142 Air Content: 5.0% Overall Placement Location: Paving, driveway, east side of project Batch time: Concrete: 570F Ticket No: NA Unit Weight (pct): NA Measured Slump (inches) 5.25 Sample Location: 30' east from grid lines D.7/42 Fracture Type Type6 TypeS Type2 Type 6 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (KW/KW) Page 4 of 10 Rone En2== Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 308966 Project No.: 0713408 Date of Service: 12/22/2007 Report Date: 01/22/2008 Project: Point West VI Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Set No. Tested (days) (in) (in') (Ibs) (psi) 4 1 12/29/2007 7 6.00 28.27 154,150 5,450 4 2 01/19/2008 28 6.00 28.27 207,600 7,340 4 3 01/19/2008 28 6.00 28.27 211,540 7,480 Average 7,410 4 4 02/16/2008 56 Contractor: Duke Construction, LP Concrete Supplier: Potter Concrete Plant: On site Specification Requirements Strength: 4,000 psi @28 days Slump (in.): 4" - 6" Air (%): 4% - 6% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1 064 ASTM C-138 ASTM C-39 ~EJ ~Q] [ill] LSJ DO D Type 1 Type 2 Type 3 Type 4 Type 5 PROJECT DATA Mix Design 1.0.: 7753 Placement Date: 12/22/2007 Weather Conditions: Clear Time Sampled: 08:45am Temperature - Air: 550F Truck No: 137 Air Content: 4.5% Overall Placement Location: Paving, driveway, east side of project Batch time: Concrete: 640F Ticket No: NA Unit Weight (pet): NA Measured Slump (inches) 4.5 Sample Location: 60' east from grid line E 1/42 Fracture Type Type2 Type3 Type2 Type 6 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (KW/KW) Page 5 of 10 Rone Engineering . Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 308966 Project No.: 0713408 Date of Service: 12/22/2007 Report Date: 01/22/2008 Project: Point West VI Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Set No. Tested (days) (in) (in2) (Ibs) (psi) 5 1 12/29/2007 7 6.00 28.27 139,210 4,920 5 2 01/19/2008 28 6.00 28.27 183,740 6,500 5 3 01/19/2008 28 6.00 28.27 188,590 6,670 Average 6,580 5 4 02/16/2008 56 Contractor: Duke Construction, LP Concrete Supplier: Potter Concrete Plant: On site Specification Requirements Strength: 4,000 psi @ 28 days Slump (in.): 4" - 6" Air (%): 4% - 6% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 ~t:J ~~ [illj ~ DO D Type 1 Type 2 Type 3 Type 4 Type 5 PROJECT DATA Mix Design 1.0.: 7753 Placement Date: 12/22/2007 Weather Conditions: Clear Time Sampled: 10:32am Temperature - Air: 480F Truck No: 137 Air Content: 4.9% Overall Placement Location: Paving, driveway, east side of project Batch time: Concrete: 550F Ticket No: NA Unit Weight (pet): NA Measured Slump (inches) 4.75 Sample Location: 50' east from grid lines K.1/42 Fracture Type Type2 Type6 Type3 Type 6 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (KW/KW) Page 7 of 10 Rone Engineering . Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, 8te 600, Houston, TX 77040 4421 Freidrich, 8te 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 308966 Project No.: 0713408 Date of Service: 12/22/2007 Report Date: 01/22/2008 Project: Point West VI Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Set No. Tested (days) (in) (in') (Ibs) (psi) 6 1 12/29/2007 7 6.00 28.27 116,570 4,120 6 2 01/19/2008 28 6.00 28.27 152,200 5,380 6 3 01/19/2008 28 6.00 28.27 154,720 5,470 Average 5,430 6 4 02/16/2008 56 Contractor: Duke Construction, LP Cor crete Supplier: Potter Concrete Plant: On site Specification Requirements Strength: 4,000 psi @ 28 days Slump (in.): 4" - 6" Air (%): 4% - 6% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 ~r3 ~~ 5IE E;J DO D Type 1 Type 2 Type 3 Type 4 Type 5 PROJECT DATA Mix Design I.D.: 7753 Placement Date: 12/22/2007 Weather Conditions: Mostly cloudy, windy Time Sampled: 12:45pm Batch time: Temperature - Air: 450F Concrete: 600F Truck No: 131 Ticket No: NA Air Content: 5.7% Unit Weight (pet): NA Overall Placement Location: Paving, driveway, east side of project Measured Slump (inches) 5.0 Sample Location: 95' south, 50' east from grid lines U42 Fracture Type Type2 Type6 Type2 Type 6 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (KW/KW) Page 8 of 10