Northlake College-LR080103 K L E I N F E L D E R 2211 Century Center 8Ivd., Suite 101, Irving, Texas 75062 972-870-0808 Metro 972-953-0398 Fax 972-870-0802 4x8 CONCRETE CYLINDER COMPRESSIVE STRENGTH REPORT TO: Dallas County Community College Dist. PROJECT: North Lake College, N Campus 1505 South lamar, Suite 1015 W Sandy lake Road @ SH 121 Dallas, Texas 75215 PROJECT NO: 87015 REPORT DATE: 1/3/2008 TECHNICIAN: J. Mayo REPORT NO: 127035 Page 1 of 8 CONCRETE FOR: Pavement SW quadrant from the SW corner 5' N x 15' E CYLINDER AGE DATE DATE AVG. CYLINDER CYLINDER FRACTURE TOTAL COMPRESSIVE MARK DAYS CAST TESTED DIAMETER, IN. AREA, IN.2 TYPE LOAD, LBS STRENGTH, PSI 127035A 7 12/6/07 12/13/07 4.00 12.57 3 56,840 4,520 1270358 28 12/6/07 1 /3/08 4.00 12.57 2 61,800 4,920 127035C 28 12/6/07 1/3/08 4.00 12.57 2 75,870 6,040 127035D HOLD 12/6/07 HOLD SUPPLIER: Southern Star AVERAGE 28 DAY STRENGTH: 5,480 MIX DESIGN: DOOOOOOO7725 28 DAY STRENGTH REQUIREMENT: 4,000 ADDITIONAL INFORMATION IF MADE BY KLEIN FELDER: r ACTUAL SPECIFIED TRUCK NO. : 26 SLUMP: 5.5 TICKET NO. : 1154923 AIR TEMP. : 40 ACCUMULATED YDS: 30 of 600 MIX TEMP. : 75 TIME CAST: 2:44 AM AIR CONTENT: 2.9 TIME IN TRUCK: 41 min WATER ADDED (gal) : 5 WEATHER: Clear UNIT WEIGHT : N/A : FRACTURE TYPES: 1 Reasonably well-formed cones on both ends, less than 1 in. (25 mm) of cracking through caps. 2 Well-formed cone on one end, vertical cracks running through caps, no well-defined cone on other end. 3 Columnar vertical cracking through both ends, no well-formed cones. 4 Diagonal fracture with no cracking through ends; tap with hammer to distinguish from Type 1. 5 Side fractures at top or bottom (occur commonly with unbonded caps). B ~. . . ~. . " nninl"r1 NOTES: . Compressive strengths determined in ac=rdance with ASTM C39. . Cross-sectional area, diameter and length are standard unless otherwise noted. . Portions of the information contained in this report have been furnished by others. . Cylinders cured in laboratory in accordance with ASTM C31 unless otherwise noted. . Unbonded caps utilized in accordance with ASTM C1231 unless otherwise noted. Because of the violent release of energy stored in pads, the broken cylinder rarely exhibits conical fracture typical of capped cylinders and the sketches of types of fracture in Test Method C39 are not descriptive. . Samples taken in accordance with ASTM C172 where practicable. . When applicable, the following test procedures were used: Slump ASTM C143; Unit Weight ASTM C138; Air Content ASTM C173/ C231: Temperature ASTM C1064 Reports to: Starling Richardson Const.; Attn: Eric Stanaland (eps@starlingrichardson.com) KLEIN FELDER Starling Richardson Const.; Attn: Andy Munoz (amunoz@starlingrichardson.com) U?f /;;~~ DCCCD Bond Office; Attn: Brenda Spinelli (brenda.spinelli@dcccd.edu) DCCCD Bond Office; Attn: James Williams Games.williams@dcccd.edu) DCCCD Bond Office; Attn: Mike Daniels (mike.daniels@dcccd.edu) 7JOe' Peters, P.~, Jacobs; Attn: Andrea Stogner (Andrea.stogner@jacobs.com) Jacobs; Attn: Jennifer Blount (Jennifer.blount@jacobs.com) 1- City of Coppell; Attn: Larry Davis 1- City of Coppell; Attn: Lee Stone The results shown on this report ere for the exclusive use of the client for whom they were obtained and apply only to the samples tested and/or inspected. They are not intended to be indicative of the qualities of apparently identical products. The use of our name must receive prior written approval. Reports must be reproduced in their entirety. K l E I N F E L D E R 2211 Century Center Blvd., Suite 101, Irving, Texas 75062 972-870-0808 Metro 972-953-0398 Fax 972-870-0802 4x8 CONCRETE CYLINDER COMPRESSIVE STRENGTH REPORT TO: Dallas County Community College Dist. PROJECT: North Lake College, N Campus 1505 South Lamar, Suite 1015 W Sandy Lake Road @ SH 121 Dallas, Texas 75215 PROJECT NO: 87015 REPORT DATE: 1/3/2008 TECHNICIAN: J. Mayo REPORT NO: 127035 Page 2 of 8 CONCRETE FOR: Pavement SW quadrant from the SW corner 85' W x 20' N CYLINDER AGE DATE DATE AVG. CYLINDER CYLINDER FRACTURE TOTAL COMPRESSIVE MARK DAYS CAST TESTED DIAMETER, IN. AREA,IN.2 TYPE LOAD,LBS STRENGTH, PSI 127036A 7 12/6/07 12/13/07 4.00 12.57 3 55,620 4,430 127036B 28 12/6/07 1/3/08 4.00 12.57 1 70,210 5,590 127036C 28 12/6/07 1/3/08 4.00 12.57 3 72,490 5,770 1270360 HOLD 12/6/07 HOLD SUPPLIER: Southern Star AVERAGE 28 DAY STRENGTH: 5,680 MIX DESIGN: DOOOOOOO7725 28 DAY STRENGTH REQUIREMENT: 4,000 ADDITIONAL INFORMATION IF MADE BY KLEIN FELDER: I ACTUAL I SPECIFIED TRUCK NO. : 84 SLUMP: 6.5 TICKET NO. : 1154943 AIR TEMP.: 40 ACCUMULATED YDS: 90 of 600 MIX TEMP.: 69 TIME CAST: 3:12 AM AIR CONTENT: 2.8 TIME IN TRUCK: 32 min WATER ADDED (gal) : 5 WEATHER: Clear UNIT WEIGHT: N/A : FRACTURE TYPES: 1 Reasonably well-formed cones on both ends, less than 1 in. (25 mm) of cracking through caps. 2 Well-formed cone on one end, vertical cracks running through caps, no well-defined cone on other end. 3 Columnar vertical cracking through both ends, no well-formed cones. 4 Diagonal fracture with no cracking through ends; tap with hammer to distinguish from Type 1. 5 Side fractures at top or bottom (occur commonly with unbonded caps). 6 c . nn;nt..n NOTES: . Compressive strengths determined in accordance with ASTM C39. . '-'ross-sectional area, diameter and length are standard unless otherwise noted. . Portions of the information contained in this report have been furnished by others. . Cylinders cured in laboratory in accordance with ASTM C31 unless otherwise noted. . Unbonded caps utilized in accordance with ASTM C 1231 unless otherwise noted. Because of the violent release of energy stored in pads, the broken cylinder rarely exhibits conical fracture typical of capped cylinders and the sketches of types of fracture in Test Method C39 are not descriptive. . Samples taken in accordance with ASTM C172 where practicable. . When applicable, the following test procedures were used: Slump ASTM C143; Unit Weight ASTM C138; Air Content ASTM C173/ C231; Temperature ASTM C1064 Reports to: Starling Richardson Const.; Altn: Eric Stanaland (eps@starlingrichardson.com) KLEINFELDER Starling Richardson Const.; Altn: Andy Munoz (amunoz@starlingrichardson.com) (Jif&1.- DCCCD Bond Office; Altn: Brenda Spinelli (brenda.spinelli@dcccd.edu) DCCCD Bond Office; Altn: James Williams (james.williams@dcccd.edu) DCCCD Bond Office; Altn: Mike Daniels (mike.daniels@dcccd.edu) I Jacobs; Altn: Andrea Stogner (Andrea.stogner@jacobs.com) Joel Peters, P. E. Jacobs; Altn: Jennifer Blount (Jennifer.blount@jacobs.com) 1- City of Coppell; Altn: Larry Davis 1- City of Coppell; Altn: Lee Stone The results shown on this report are for the exclusive use of the client for whom they were obtained and apply only to the samples tested and/or inspected. They are not intended to be indicative of the qualities of apparently identical products. The use of our name must receive prior written approval. Reports must be reproduced in their entirety. K l E I N F E l D E R 2211 CenturyCenter8Ivd., Suite 101, Irving, Texas 75062 972-870-0808 Metro 972-953-0398 Fax 972-870-0802 4x8 CONCRETE CYLINDER COMPRESSIVE STRENGTH REPORT TO: Dallas County Community College Dist. PROJECT: North Lake College, N Campus 1505 South Lamar, Suite 1015 W Sandy Lake Road @ SH 121 Dallas, Texas 75215 PROJECT NO: 87015 REPORT DATE: 1/3/2008 TECHNICIAN: J. Mayo REPORT NO: 127035 Page 3 of 8 CONCRETE FOR: Pavement SW quadrant from the SW corner 70' N x 40' E CYLINDER AGE DATE DATE AVG. CYLINDER CYLINDER FRACTURE TOTAL COMPRESSIVE MARK DAYS CAST TESTED DIAMETER, IN. AREA,IN.2 TYPE LOAD, LBS STRENGTH, PSI 127037A 7 12/6/07 12/13/07 4.00 12.57 3 51,920 4,130 1270378 28 12/6/07 1/3/08 4.00 12.57 2 70,140 5,580 127037C 28 12/6/07 1/3/08 4.00 12.57 2 72,500 5,770 1270370 HOLD 12/6/07 HOLD SUPPLIER: Southern Star AVERAGE 28 DAY STRENGTH: 5,675 MIX DESIGN: DOOOOOOO7725 28 DAY STRENGTH REQUIREMENT: 4,000 ADDITIONAL INFORMATION IF MADE BY KLEINFELDER: ACTUAL T SPECIFIED TRUCK NO. : 26 SLUMP: 5.25 TICKET NO. : 1154955 AIR TEMP. : 40 ACCUMULATED YDS : 120 of 600 MIX TEMP.: 71 TIME CAST: 3:37 AM AIR CONTENT: 3.7 TIME IN TRUCK: 37 min WATER ADDED (gal) : 0 WEATHER: Clear UNIT WEIGHT: N/A : FRACTURE TYPES: 1 Reasonably well-formed cones on both ends, less than 1 in (25 mm) of cracking through caps. 2 Well-formed cone on one end, vertical cracks running through caps, no well-defined cone on other end. 3 Columnar vertical cracking through both ends, no well-formed cones. 4 Diagonal fracture with no cracking through ends; tap with hammer to distinguish from Type 1. 5 Side fractures at top or bottom (occur commonly with unbonded caps). 6 . . hllt..nri NOTES: . Compressive strengths determined in accordance with ASTM C39. . Cross-sectional area, diameter and length are standard unless otherwise noted. . Portions of the information contained in this report have been furnished by others. . Cylinders cured in laboratory in accordance with ASTM C31 unless otherwise noted. . Unbonded caps utilized in accordance with ASTM C 1231 unless otherwise noted. Because of the violent release of energy stored in pads, the broken cylinder rarely exhibits conical fracture typical of capped cylinders and the sketches of types of fracture in Test Method C39 are not descriptive. . Samples taken in accordance with ASTM C172 where practicable. . When applicable, the following test procedures were used: Slump ASTM C143; Unit Weight ASTM C138; Air Content ASTM C173/ C231; Temperature ASTM C1064 Reports to: Starling Richardson Const.; Attn: Eric Stanaland (eps@starlingrichardson.com) GariJ-a/ Starling Richardson Const.; Attn: Andy Munoz (amunoz@starlingrichardson.com) DCCCD Bond Office; Attn: Brenda Spinelli (brenda.spinelli@dcccd.edu) DCCCD Bond Office; Attn: James Williams (james.williams@dcccd.edu) DCCCD Bond Office; Attn: Mike Daniels (mike.daniels@dcccd.edu) f .... v Jacobs; Attn: Andrea Stogner (Andrea.stogner@jacobs.com) Joel Peters, P.E. Jacobs; Attn: Jennifer Blount (Jennifer.blount@jacobs.com) 1- City of Coppell; Attn: Larry Davis 1- City of Coppell; Attn: Lee Stone The results shown on this report are for the exclusive use of the client for whom they were obtained and apply only to the samples tested and/or inspected. They are not intended to be indicative of the quamies of apparently identical products. The use of our name must receive prior written approval. Reports must be reproduced in their entirety. K L E I N F E L D E R 2211 Century Center Blvd., Suite 101, Irving, Texas 75062 972-870-0808 Metro 972-953-0398 Fax 972-870-0802 4x8 CONCRETE CYLINDER COMPRESSIVE STRENGTH REPORT TO: Dallas County Community College Dist. PROJECT: North Lake College, N Campus 1505 South Lamar, Suite 1015 W Sandy Lake Road @ SH 121 Dallas, Texas 75215 PROJECT NO: 87015 REPORT DATE: 1/3/2008 TECHNICIAN: J. Mayo REPORT NO: 127035 Page 4 of 8 CONCRETE FOR: Pavement SW quadrant from the SW corner 90' E x 80' N CYLINDER AGE DATE DATE AVG. CYLINDER CYLINDER FRACTURE TOTAL COMPRESSIVE MARK DAYS CAST TESTED DIAMETER, IN. AREA,IN.2 TYPE LOAD,LBS STRENGTH, PSI 127038A 7 12/6/07 12/13/07 4.00 12.57 3 56,120 4,470 127038B 28 12/6/07 1/3/08 4.00 12.57 2 68,080 5,420 127038C 28 12/6/07 1/3/08 4.00 12.57 2 71,990 5,730 1270380 HOLD 12/6/07 HOLD SUPPLIER: Southern Star AVERAGE 28 DAY STRENGTH: 5,575 MIX DESIGN: DOOOOOOO7725 28 DAY STRENGTH REQUIREMENT: 4,000 ADDITIONAL INFORMATION IF MADE BY KLEIN FELDER: ACTUAL I SPECIFIED I TRUCK NO. : 1015 SLUMP: 5.75 TICKET NO. : 1154986 AIR TEMP. : 40 ACCUMULATED YDS: 190 of 600 MIX TEMP.: 71 TIME CAST: 4:17 AM AIR CONTENT: 3.0 TIME IN TRUCK: 32 min WATER ADDED (gal) : 0 WEATHER: Clear UNIT WEIGHT: N/A : FRACTURE TYPES: 1 Reasonably well-formed cones on both ends, less than 1 in, (25 mm) of cracking through caps, 2 Well-formed cone on one end, vertical cracks running through caps, no well-defined cone on other end, 3 Columnar vertical cracking through both ends, no well-formed cones, 4 Diagonal fracture with no cracking through ends; tap with hammer to distinguish from Type 1. 5 Side fractures at top or bottom (occur commonly with unbonded caps), R . . , ,Ol'lint...-i NOTES: . Compressive strengths determined in accordance with ASTM C39, . Cross-sectional area, diameter and length are standard unless otherwise noted, . Portions of the information contained in this report have been furnished by others, . Cylinders cured in laboratory in accordance with ASTM C31 unless otherwise noted, . Unbonded caps utilized in accordance with ASTM C1231 unless otherwise noted, Because of the violent release of energy stored in pads, the broken cylinder rarely exhibits conical fracture typical of capped cylinders and the sketches of types of fracture in Test Method C39 are not descriptive, . Samples taken in accordance with ASTM C172 where practicable, . When applicable, the following test procedures were used: Slump ASTM C143; Unit Weight ASTM C138; Air Content ASTM C173/ C231; Temperature ASTM C1064 Reports to: Starling Richardson Const.; Alln: Eric Stanaland (eps@starlingrichardson,com) w~~ Starling Richardson Const.; Alln: Andy Munoz (amunoz@starlingrichardson.com) DCCCD Bond Office; Alln: Brenda Spinelli (brenda,spinelli@dcccd.edu) DCCCD Bond Office; Alln: James Williams (james.williams@dcccd.edu) DCCCD Bond Office; Alln: Mike Daniels (mike.daniels@dcccd,edu) f ..... Jacobs; Alln: Andrea Stogner (Andrea.stogner@jacobs,com) Joel Peters, P.E. Jacobs; Alln: Jennifer Blount (Jennifer,blount@jacobs.com) 1- City of Coppell; Alln: Larry Davis 1- City of Coppell; Alln: Lee Stone The results shown on this report are for the exclusive use of the client for whom they were obtained and apply only to the samples tested and/or inspected, They are not intended to be indicative of the qualities of apparently identical products, The use of our name must receive prior written approval. Reports must be reproduced in their entirety. K L E I N F E L D E R 2211 CenturyCenter8Ivd., Suite 101, INing, Texas 75062 972-870-0808 Metro 972-953-0398 Fax 972-870-0802 4x8 CONCRETE CYLINDER COMPRESSIVE STRENGTH REPORT TO: Dallas County Community College Dist. PROJECT: North Lake College, N Campus 1505 South Lamar, Suite 1015 W Sandy Lake Road @ SH 121 Dallas, Texas 75215 PROJECT NO: 87015 REPORT DATE: 1/3/2008 TECHNICIAN: J. Mayo REPORT NO: 127035 Page 5 of 8 CONCRETE FOR: Pavement NW quadrant from NW corner 200' S x 50' E CYLINDER AGE DATE DATE AVG. CYLINDER CYLINDER FRACTURE TOTAL COMPRESSIVE MARK DAYS CAST TESTED DIAMETER, IN. AREA, IN.2 TYPE LOAD,LBS STRENGTH, PSI 127039A 7 12/6/07 12/13/07 4.00 12.57 3 43,240 3,440 1270398 28 12/6/07 1/3/08 4.00 12.57 2 60,740 4,830 127039C 28 12/6/07 1/3/08 4.00 12.57 3 60,690 4,830 1270390 HOLD 12/6/07 HOLD SUPPLIER: Southern Star AVERAGE 28 DAY STRENGTH: 4,830 MIX DESIGN: 000000007725 28 DAY STRENGTH REQUIREMENT: 4,000 ADDITIONAL INFORMATION IF MADE BY KLEINFELDER: ACTUAL I SPECIFIED I TRUCK NO. : 905 SLUMP: 5.75 TICKET NO. : 11 55012 AIR TEMP. : 40 ACCUMULATED YDS: 240 of 600 MIX TEMP. : 69 TIME CAST: 5:32 AM AIR CONTENT: 2.5 TIME IN TRUCK: 65min WATER ADDED (gal) : 0 WEATHER: Clear UNIT WEIGHT: N/A : FRACTURE TYPES: 1 Reasonably well-formed cones on both ends. less than 1 in. (25 mm) of cracking through caps. 2 Well-formed cone on one end, vertical cracks running through caps, no well-defined cone on other end. 3 Columnar vertical cracking through both ends, no well-formed cones. 4 Diagonal fracture with no cracking through ends; tap with hammer to distinguish from Type 1. 5 Side fractures at top or bottom (occur commonly with unbonded caps). fI . . 1; hilt Ann NOTES: . Compressive strengths determined in accordance with ASTM C39. . Cross-sectional area, diameter and length are standard unless otherwise noted. . Portions of the information contained in this report have been furnished by others. . Cylinders cured in laboratory in accordance with ASTM C31 unless otherwise noted. . Unbonded caps utilized in accordance with ASTM C1231 unless otherwise noted. Because of the violent release of energy stored in pads, the broken cylinder rarely exhibits conical fracture typical of capped cylinders and the sketches of types of fracture in Test Method C39 are not descriptive. . Samples taken in accordance with ASTM C172 where practicable. . When applicable, the following test procedures were used: Slump ASTM C143; Unit WeightASTM C138; Air Content ASTM C173/ C231; Temperature ASTM C1064 Reports to: Starling Richardson Const.; AUn: Eric Stanaland (eps@starlingrichardson.com) KLEINFELDER Starling Richardson Const.; AUn: Andy Munoz (amunoz@starlingrichardson.com) (bfj?~_ DCCCD Bond Office; Attn: Brenda Spinelli (brenda.spinelli@dcccd.edu) DCCCD Bond Office; Attn: James Williams (james.williams@dcccd.edu) DCCCD Bond Office; Attn: Mike Daniels (mike.daniels@dcccd.edu) !;~ ~ ;- Jacobs; Attn: Andrea Stogner (Andrea.stogner@jacobs.com) Joel Peters, P.E. Jacobs; AUn: Jennifer Blount (Jennifer.blount@jacobs.com) 1- City of Coppell; Attn: Larry Davis 1- City of Coppell; Attn: Lee Stone The results shown on this report are for the exclusive use of the client for whom they were obtained and apply only to the samples tested andlor inspected. They are not intended to be indicative of the qualities of apparently identical products. The use of our name must receive prior written approval. Reports must be reproduced in their entirety. K L E I N F E L D E R 2211 Century Center Blvd., Suite 101, Irving, Texas 75062 972-870-0808 Metro 972-953-0398 Fax 972-870-0802 4x8 CONCRETE CYLINDER COMPRESSIVE STRENGTH REPORT TO: Dallas County Community College Dist. PROJECT: North Lake College, N Campus 1505 South Lamar, Suite 1015 W Sandy Lake Road @ SH 121 Dallas, Texas 75215 PROJECT NO: 87015 REPORT DATE: 1/3/2008 TECHNICIAN: J. Mayo REPORT NO: 127035 Page 6 of 8 CONCRETE FOR: Pavement NW quadrant from NW corner 200' S x 90' E CYLINDER AGE DATE DATE AVG. CYLINDER CYLINDER FRACTURE TOTAL COMPRESSIVE MARK DAYS CAST TESTED DIAMETER, IN. AREA,IN.2 TYPE LOAD, LBS STRENGTH, PSI 127040A 7 12/6/07 12/13/07 4.00 12.57 3 51,380 4,090 127040B 28 12/6/07 1/3/08 4.00 12.57 2 67,340 5,360 127040C 28 12/6/07 1/3/08 4.00 12.57 2 64,960 5,170 1270400 HOLD 12/6/07 HOLD SUPPLIER: Southern Star AVERAGE 28 DAY STRENGTH: 5,265 MIX DESIGN: DOOOOOOO7725 28 DAY STRENGTH REQUIREMENT: 4,000 ADDITIONAL INFORMATION IF MADE BY KLEINFELDER: I ACTUAL I SPECIFIED TRUCK NO. : 5019 SLUMP; 4.5 TICKET NO. : 1155075 AIR TEMP.: 40 ACCUMULATED YDS : 300 of 600 MIX TEMP. : 73 TIME CAST; 6:06 AM AIR CONTENT: 3.4 TIME IN TRUCK; 29min WATER ADDED (gal) : 0 WEATHER: Clear UNIT WEIGHT: N/A : . FRACTURE TYPES: 1 Reasonably well-formed cones on both ends. less than 1 in. (25 mm) of cracking through caps. 2 Well-formed cone on one end, vertical cracks running through caps, no well-defined cone on other end. 3 Columnar vertical cracking through both ends, no well-formed cones. 4 Diagonal fracture with no cracking through ends; tap with hammer to distinguish from Type 1. 5 Side fractures at top or bottom (occur commonly with unbonded caps). F; -. . ~. . NOTES: 0 Compressive strengths determined in accordance with ASTM C39. 0 Cross-sectional area, diameter and length are standard unless otherwise noted. o Portions of the information contained in this report have been furnished by others. 0 Cylinders cured in laboratory in accordance with ASTM C31 unless otherwise noted. 0 Unbonded caps utilized in accordance with ASTM C1231 unless otherwise noted. Because of the violent release of energy stored in pads, the broken cylinder rarely exhibits conical fracture typical of capped cylinders and the sketches of types of fracture in Test Method C39 are not descriptive. o Samples taken in accordance with ASTM C172 where practicable. 0 When applicable, the following test procedures were used: Slump ASTM C143; Unit Weight ASTM C138; Air ContentASTM C173/ C231; Temperature ASTM C1064 Reports to; Starling Richardson Const.; Altn; Eric Stanaland (eps@starlingrichardson.com) C;;;i~ Starling Richardson Const.; Altn: Andy Munoz (amunoz@starlingrichardson.com) DCCCD Bond Office; Altn: Brenda Spinelli (brenda.spinelli@dcccd.edu) DCCCD Bond Office; Altn: James Williams (james.williams@dcccd.edu) DCCCD Bond Office; Altn; Mike Daniels (mike.daniels@dcccd.edu) I Joel Peters, P.E. Jacobs; Altn: Andrea Stogner (Andrea.stogner@jacobs.com) Jacobs; Altn: Jennifer Blount (Jennifer.blount@jacobs.com) 1- City of Coppell; Altn: Larry Davis 1- City of Coppell; Altn: Lee Stone The results shown on this report are for the exclusive use of the client for whom they were obtained and apply only to the samples tested andlor inspected. They are not intended to be indicative of the qualities of apparently identical products. The use of our name must receive prior written approval. Reports must be reproduced in their entirety. K L E I N F E L D E R 2211 Century Center Blvd., Suite 101, Irving, Texas 75062 972-870-0808 Metro 972-953-0398 Fax 972-870-0802 4x8 CONCRETE CYLINDER COMPRESSIVE STRENGTH REPORT TO: Dallas County Community College Dist. PROJECT: North Lake College, N Campus 1505 South Lamar, Suite 1015 W Sandy Lake Road @ SH 121 Dallas, Texas 75215 PROJECT NO: 87015 REPORT DATE: 1/3/2008 TECHNICIAN: J. Mayo REPORT NO: 127035 Page 7 of 8 CONCRETE FOR: Pavement NW quadrant from NW corner 70' S x 50' E CYLINDER AGE DATE DATE AVG. CYLINDER CYLINDER FRACTURE TOTAL COMPRESSIVE MARK DAYS CAST TESTED DIAMETER, IN. AREA, IN.2 TYPE LOAD, LBS STRENGTH, PSI 127041A 7 12/6/07 12/13/07 4.00 12.57 3 48,990 3,900 127041B 28 12/6/07 1/3/08 4.00 12.57 2 62,980 5,010 127041C 28 12/6/07 1/3/08 4.00 12.57 5 63,600 5,060 1270410 HOLD 12/6/07 HOLD SUPPLIER: Southern Star AVERAGE 28 DAY STRENGTH: 5,035 MIX DESIGN: 000000007725 28 DAY STRENGTH REQUIREMENT: 4,000 ADDITIONAL INFORMATION IF MADE BY KLEIN FELDER: ACTUAL I SPECIFIED TRUCK NO. : 1015 SLUMP: 6.0 TICKET NO. : 11551 08 AIR TEMP. : 40 ACCUMULATED YDS: 340 of 600 MIX TEMP.: 74 TIME CAST: 6:49 AM AIR CONTENT: 3.5 TIME IN TRUCK: 39min WATER ADDED (gal) : 0 WEATHER: Clear UNIT WEIGHT: N/A : FRACTURE TYPES: 1 Reasonably well-formed cones on both ends. less than 1 in. (25 mm) of cracking through caps. 2 Well-formed cone on one end, vertical cracks running through caps, no well-defined cone on other end. 3 Columnar vertical cracking through both ends, no well-formed cones. 4 Diagonal fracture with no cracking through ends; tap with hammer to distinguish from Type 1. 5 Side fractures at top or bottom (occur commonly with unbonded caps). f\ ~imil"r In Tvn.. !i NOTES: . Compressive strengths determined in accordance with ASTM C39. . Cross-sectional area, diameter and length are standard unless otherwise noted. . Portions of the information contained in this report have been furnished by others. . Cylinders cured in laboratory in accordance with ASTM C31 unless otherwise noted. . Unbonded caps utilized in accordance with ASTM C 1231 unless otherwise noted. Because of the violent release of energy stored in pads, the broken cylinder rarely exhibits conical fracture typical of capped cylinders and the sketches of types of fracture in Test Method C39 are not descriptive. . Samples taken in accordance with ASTM C172 where practicable. . When applicable, the following test procedures were used: Slump ASTM C143; Unit WeightASTM C138; Air Content ASTM C173/ C231; Temperature ASTM C1064 Reports to: Starling Richardson Const.; AUn: Eric Stanaland (eps@starlingrichardson.com) ~ KLEIN FELDER Starling Richardson Const.; AUn: Andy Munoz (amunoz@starlingrichardson.com) ~~/~ DCCCD Bond Office; AUn: Brenda Spinelli (brenda.spinelli@dcccd.edu) DCCCD Bond Office; AUn: James Williams Oames.williams@dcccd.edu) DCCCD Bond Office; AUn: Mike Daniels (mike.daniels@dcccd.edu) fI \,.,. , ..... Jacobs; AUn: Andrea Stogner (Andrea.stogner@jacobs.com) Joel Peters, P.E. Jacobs; Attn: Jennifer Blount (Jennifer.blount@jacobs.com) 1- City of Coppell; AUn: Larry Davis 1- City of Coppell; Attn: Lee Stone The resuits shown on this report are for the exclusive use of the client for whom they were obtained and apply only to the samples tested and/or inspected. They are not intended to be indicative of the qualities of apparently identical products. The use of our name must receive prior written approval. Reports must be reproduced in their entirety. K L E I N F E L D E R 2211 Century Center Blvd., Suite 101, Irving, Texas 75062 972-870-0808 Metro 972-953-0398 Fax 972-870-0802 4x8 CONCRETE CYLINDER COMPRESSIVE STRENGTH REPORT TO: Dallas County Community College Dist. PROJECT: North Lake College, N Campus 1505 South Lamar, Suite 1015 W Sandy Lake Road @ SH 121 Dallas, Texas 75215 PROJECT NO: 87015 REPORT DATE: 1/3/2008 TECHNICIAN: J. Mayo REPORT NO: 127035 Page 8 of 8 CONCRETE FOR: Pavement NW quadrant from NW corner 60' S x 100' E CYLINDER AGE DATE DATE AVG. CYLINDER CYLINDER FRACTURE TOTAL COMPRESSIVE MARK DAYS CAST TESTED DIAMETER, IN. AREA, IN.2 TYPE LOAD,LBS STRENGTH, PSI 127042A 7 12/6/07 12/13/07 4.00 12.57 3 48,970 3,900 1270428 28 12/6/07 1/3/08 4.00 12.57 1 64,390 5,120 127042C 28 12/6/07 1/3/08 4.00 12.57 2 65,000 5,170 1270420 HOLD 12/6/07 HOLD SUPPLIER: Southern Star AVERAGE 28 DAY STRENGTH: 5,145 MIX DESIGN: DOOOOOOO7725 28 DAY STRENGTH REQUIREMENT: 4,000 ADDITIONAL INFORMATION IF MADE BY KLEINFELDER: ACTUAL I SPECIFIED I TRUCK NO. : 905 SLUMP: 6.0 TICKET NO. : 1155206 AIR TEMP. : 45 ACCUMULATED YDS : 400 of 450 MIX TEMP. : 75 TIME CAST: 7:24 AM AIR CONTENT: 3.1 TIME IN TRUCK: 27min WATER ADDED (gal) : 0 WEATHER: Clear UNIT WEIGHT: N/A : FRACTURE TYPES: 1 Reasonably well-formed cones on both ends, less than 1 in. (25 mm) of cracking through caps. 2 Well-formed cone on one end, vertical cracks running through caps, no well-defined cone on other end. 3 Columnar vertical cracking through both ends, no well-formed cones. 4 Diagonal fracture with no cracking through ends; tap with hammer to distinguish from Type 1. 5 Side fractures at top or bottom (occur commonly with unbonded caps). 6 5. but end NOTES: . Compressive strengths determined in accordance with ASTM C39. . Cross-sectional area, diameter and length are standard unless otherwise noted. . Portions of the information contained in this report have been furnished by others. . Cylinders cured in laboratory in accordance with ASTM C31 unless otherwise noted. . Unbonded caps utilized in accordance with ASTM C 1231 unless otherwise noted. Because of the violent release of energy stored in pads, the broken cylinder rarely exhibits conical fracture typical of capped cylinders and the sketches of types of fracture in Test Method C39 are not descriptive. . Samples taken in accordance with ASTM C172 where practicable. . When applicable, the following test procedures were used: Slump ASTM C143; Unit Weight ASTM C138; Air Content ASTM C173/ C231; Temperature ASTM C1064 Reports to: Starling Richardson Const.; AlIn: Eric Stanaland (eps@starlingrichardson.com) G;;~~ Starling Richardson Const.; AlIn: Andy Munoz (amunoz@starlingrichardson.com) DCCCD Bond Office; AlIn: Brenda Spinelli (brenda.spinelli@dcccd.edu) DCCCD Bond Office; AlIn: James Williams Oames.williams@dcccd.edu) DCCCD Bond Office; Attn: Mike Daniels (mike.daniels@dcccd.edu) f ~ '-' Jacobs; AlIn: Andrea Stogner (Andrea.stogner@jacobs.com) Joel Peters, P.E. Jacobs; Attn: Jennifer Blount (Jennifer.blount@jacobs.com) 1- City of Coppell; Attn: Larry Davis 1- City of Coppell; Attn: Lee Stone The results shown on this report are for the exclusive use of the client for whom they were obtained and apply only to the samples tested and/or inspected. They are not intended to be indicative of the qualities of apparently identical products. The use of our name must receive prior written approval. Reports must be reproduced in their entirety.