Report of Concrete Compressive Strength Test
Report No.: 304062
Project No.: 0712786
Date of Service: 11/0212007
Report Date: 12111/2007
Project: Gateway Business Center
Coppell, Texas
Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples
back to the laboratory for curing and testing in accordance with applicable standards.
PROJECT DATA
Contractor: Constructors & Associates
Concrete Supplier: Redi Mix
Plant: 88
Specification Requirements
Strength: 3,600 psi @ 28 days
Slump (in.): 3" - 5"
Air (%): 4% - 6%
Test Method: ASTM C-172
ASTM C-31 (except 1 0.1 .2)
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-138
ASTM C-39
Mix Design 1.0.: 23601524
Placement Date: 11/0212007
Weather Conditions: Cloudy
Time Sampled: 05:30am
Temperature - Air: 650F
Truck No: 1382
Air Content: 3.0%
Overall Placement Location:
Fire lane and park paving on north side of building 2
Measured
Slump
(inches)
8.0
Batch time: 04:37am
Concrete: 710F
Ticket No: 88056125
Unit Weight (pct): NA
Sample Location:
20' north, 55' east from corner of building 2
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12"
Cylinder Maximum Compressive
Marked Date Age Diameter Area Load Strength Fracture
Set No. Tested (days) (in) (in') (Ibs) (psi) Type
2 1 11/09/2007 7 6.00 28.27 62,860 2,220 Shear
2 2 11/30/2007 28 6.00 28.27 91,700 3,240 Cone/Shear
2 3 11/30/2007 28 6.00 28.27 97,270 3,440 Cone/Split
Average 3,340 *
2 4 12/28/2007 56
* Does not comply with specified strength
Remarks: Water added at site: 15 gallons
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd.
(CH/KW) Page 2 of 5
Rone Eni~
Client: Transwestern Commercial Services
5001 Spring Valley
Dallas, TX 75244
8908 Ambassador Row, Dallas, TX 75247
7701 W Little York, Ste 600, Houston, TX 77040
4421 Freldrlch, Ste 195, Austin, TX 78744
Corporate Phone: (214) 630-9745
Report of Concrete Compressive Strength Test
Report No.: 304062
Project No.: 0712786
Date of Service: 11/02/2007
Report Date: 12/11/2007
Project: Gateway Business Center
Coppell, Texas
Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples
back to the laboratory for curing and testing in accordance with applicable standards.
PROJECT DATA
Contractor: Constructors & Associates
Concrete Supplier: Redi Mix
Plant: 88
Specification Requirements
Strength: 3,600 psi @ 28 days
Slump (in.): 3" - 5"
Air (%): 4% - 6%
Test Method: ASTM C-172
ASTM C-31 (except 10.1.2)
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-138
ASTM C-39
Mix Design 1.0.: 23601524
Placement Date: 11/02/2007
Weather Conditions: Cloudy
Time Sampled: 08:00am
Temperature - Air: 650F
Truck No: 1206
Air Content: 4.2%
Overall Placement Location:
Fire lane and park paving on north side of building 2
Measured
Slump
(inches)
8.5
Batch time: 06:27am
Concrete: 710F
Ticket No: 88056137
Unit Weight (pet): NA
Sample Location:
25' north, 5' west from corner of building 2
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12"
Cylinder Maximum Compressive
Marked Date Age Diameter Area Load Strength Fracture
Set No. Tested (days) (in) (in') (Ibs) (psi) Type
3 1 11/09/2007 7 6.00 28.27 58,830 2,080 Shear
3 2 11/30/2007 28 6.00 28.27 93,610 3,310 Cone/Split
3 3 11/30/2007 28 6.00 28.27 96,250 3,400 Cone/Split
Average 3,360 *
3 4 12/28/2007 56
* Does not comply with specified strength
Remarks: Water added at site: 10 gallons
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd.
(CH/KW) Page 3 of 5
Rone En~==
Client: Transwestern Commercial Services
5001 Spring Valley
Dallas, TX 75244
8908 Ambassador Row, Dallas, TX 75247
7701 W Little York, Ste 600, Houston, TX n040
4421 Freidrlch, Ste 195, Austin, TX 78744
Corporate Phone: (214)630-9745
Report of Concrete Compressive Strength Test
Report No.: 304062
Project No.: 0712786
Date of Service: 11/02/2007
Report Date: 12/11/2007
Project: Gateway Business Center
Coppell, Texas
Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples
back to the laboratory for curing and testing in accordance with applicable standards.
PROJECT DATA
Contractor: Constructors & Associates
Concrete Supplier: Redi Mix
Plant: 88
Specification Requirements
Strength: 3,600 psi @ 28 days
Slump (in.): 3" - 5"
Air (%): 4% - 6%
Test Method: ASTM C-172
ASTM C-31 (except 10.1.2)
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-138
ASTM C-39
Mix Design I.D.: 23601524
Placement Date: 11/02/2007
Weather Conditions: Cloudy
Time Sampled: 09:30am
Temperature - Air: 650F
Truck No: 1070
Air Content: 3.9%
Overall Placement Location:
Fire lane and park paving on north side of building 2
Measured
Slump
(inches)
8.0
Batch time: 07:49am
Concrete: 710F
Ticket No: 88056146
Unit Weight (pet): NA
Sample Location:
35' east, 20' north from southeast building comer
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12"
Cylinder Maximum Compressive
Marked Date Age Diameter Area Load Strength Fracture
Set No. Tested (days) (in) (in") (Ibs) (psi) Type
- -
4 1 11/09/2007 7 6.00 28.27 71,400 2,530 Shear
4 2 11/30/2007 28 6.00 28.27 95,600 3,380 Shear
4 3 11/30/2007 28 6.00 28.27 99,510 3,520 Cone/Shear
Average 3,450 *
4 4 12/28/2007 56
* Does not comply with specified strength
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd.
(CHIKW) Page 4 of 5
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12"
Cylinder Maximum Compressive
Marked Date Age Diameter Area Load Strength Fracture
Set No. Tested (days) (in) (in') (Ibs) (psi) Type
1 1 11/15/2007 7 6.00 28.27 77,760 2,750 Cone/Split
1 2 12/06/2007 28 6.00 28.27 104,510 ~o Shear
1 3 12/06/2007 28 6.00 28.27 103,230 50 Cone/Split
Average 3,670
1 4 01/03/2008 56
Rone Eni==
Client: Transwestern Commerci
5001 Spring Valle
Dallas, TX 7
Constructors & Associates
pplier: Redi-Mix
Plant: P136
Specification Requirements
Strength: 3,600 psi @ 28 days
Slump (in.): 3" - 5"
Air (%): 4% - 6%
Test Method: ASTM C-172
ASTM C-31 (except 10.1.2)
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-138
ASTM C-39
Remarks: Water added at site: 5 gallons
8908 Ambassador Row, Dallas, TX 75247
7701 W Little York, Ste 600, Houston, TX 77040
4421 Freidrich, Ste 195, Austin, TX 78744
Corporate Phone: (214) 630-9745
Report of Concrete Compressive Strength Test
Report No.: 304766
Project No.: 0712786
Date of Service: 11/08/2007
Report Date: 12/11/2007
PROJECT DATA
Mix Design 1.0.: 23601524
Placement Date: 11/08/2007
Weather Conditions: Clear
Time Sampled: 07:15am
Temperature - Air: 600F
Truck No: 1358
Air Content: NA
Overall Placement Location:
Paving, between buildings 1 and 2
Batch time: 06:02am
Concrete: 610F
Ticket No: 13601416
Unit Weight (pet): NA
Measured
Slump
(inches)
8.0
Sample Location:
25' west, 10' south from southwest corner of building 2
~\l~
'\1\~O 8
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd.
(TMlED) Page 1 of 4
Rone Eni==
Client: Transwestern Commercial Services
5001 Spring Valley
Dallas, TX 75244
8908 Ambassador Row, Dallas, TX 75247
7701 W Little York, Ste 600, Houston, TX n040
4421 Freldrich, Ste 195, Austin, TX 78744
Corporate Phone: (214) 630-9745
Report of Concrete Compressive Strength Test
Report No.: 304766
Project No.: 0712786
Date of Service: 11/08/2007
Report Date: 12/11/2007
Project: Gateway Business Center
Coppell, Texas
Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples
back to the laboratory for curing and testing in accordance with applicable standards.
PROJECT DATA
Contractor: Constructors & Associates
Concrete Supplier: Redi-Mix
Plant: P136
Specification Requirements
Strength: 3,600 psi @ 28 days
Slump (in.): 3" - 5"
Air (%): 4% - 6%
Test Method: ASTM C-172
ASTM C-31 (except 10.1.2)
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-138
ASTM C-39
Batch time: 04:33am
Concrete: 650F
Ticket No: 1360369
Unit Weight (pet): NA
Measured
Slump
(inches)
5.0
Mix Design I.D.: 23601524
Placement Date: 11/08/2007
Weather Conditions: Clear
Time Sampled: 05:30am
Temperature - Air: 600F
Truck No: 1190
Air Content: NA
Overall Placement Location:
Paving for parking, 1) southwest parking area, building 2, 2) parking area between
buildings 1 and 2 (cont below)
Sample Location:
40' south, 60' west from southwest corner of building 2
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12"
Cylinder Maximum Compressive
Marked Date Age Diameter Area Load Strength Fracture
Set No. Tested (days) (in) (in') (Ibs) (psi) Type
2 1 11/15/2007 7 6.00 28.27 99,710 3,530 Cone/Split
2 2 12/06/2007 28 6.00 28.27 118,670 4,200 Cone/Split
2 3 12/06/2007 28 6.00 28.27 107,230 3,790 Cone/Split
Average 3,990
2 4 01/03/2008 56
Remarks: Cant: 3) Parking area off southeast corner of building 2.
Water added at site: 10 gallons
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided fortesling. We assume no responsibility for variation in quality
(composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, LId.
(TMIED) Page 2 of 4
Rone Eni~
Client: Transwestern Commercial Services
5001 Spring Valley
Dallas, TX 75244
8908 Ambassador Row, Dallas, TX 75247
7101 W Little York, Ste 600, Houston, TX 71040
4421 Freidrlch, Ste 195, Austin, TX 78744
Corporate Phone: (214) 630-9745
Report of Concrete Compressive Strength Test
Report No.: 304766
Project No.: 0712786
Date of Service: 11/08/2007
Report Date: 12/11/2007
Project: Gateway Business Center
Coppell, Texas
Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples
back to the laboratory for curing and testing in accordance with applicable standards.
PROJECT DATA
Contractor: Constructors & Associates
Concrete Supplier: Redi-Mix
Plant: P136
Specification Requirements
Strength: 3,600 psi @ 28 days
Slump (in.): 3" - 5"
Air (%): 4% - 6%
Test Method: ASTM C-172
ASTM C-31 (except 10.1.2)
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-138
ASTM C-39
Batch time: 08:30am
Concrete: 600F
Ticket No: 13601453
Unit Weight (pet): NA
Measured
Slump
(inches)
8.0
Mix Design 1.0.: 23601524
Placement Date: 11/08/2007
Weather Conditions: Clear
Time Sampled: 09:00am
Temperature - Air: 600F
Truck No: 1193
Air Content: 2.5%
Overall Placement Location:
Paving, 1) southwest from building 2, 2) southeast corner of building 2, 3) between
buildings 1 and 2
Sample Location:
60' east, 20' south from southeast corner of building 2
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12"
Cylinder Maximum Compressive
Marked Date Age Diameter Area Load Strength Fracture
Set No. Tested (days) (in) (in') (Ibs) (psi) Type
3 1 11/15/2007 7 6.00 28.27 92,760 3,280 Cone/Split
3 2 12/06/2007 28 6.00 28.27 111,850 3,960 Cone/Split
3 3 12/06/2007 28 6.00 28.27 107,670 3,810 Cone/Split
Average 3,880
3 4 01/03/2008 56
Remarks: Water added at site: 10 gallons
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd.
(TMIED) Page 3 of 4
Rone Eni==
Client: Transwestern Commercial Services
5001 Spring Valley
Dallas, TX 75244
8908 Ambassador Row, Dallas, TX 75247
7701 W Little York, Ste 600, Houston, TX 77040
4421 Freidrlch, Ste 195, Austin, TX 78744
Corporate Phone: (214) 630-9745
Report of Concrete Compressive Strength Test
Report No.: 303891
Project No.: 0712786
Date of Service: 11/01/2007
Report Date: 12/11/2007
Project: Gateway Business Center
Coppell, Texas
Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples
back to the laboratory for curing and testing in accordance with applicable standards.
PROJECT DATA
Contractor: Constructors & Associates
Concrete Supplier: Redi Mix
Plant: 88
Specification Requirements
Strength: 3,600 psi @ 28 days
Slump (in.): 3" - 5"
Air (%): 3% - 6%
Test Method: ASTM C-172
ASTM C-31 (except 10.1.2)
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-138
ASTM C-39
Measured
Slump
(inches)
4.75
Mix Design I.D.: 23601524
Placement Date: 11/01/2007
Weather Conditions: Calm, clear
Time Sampled: 04:00am Batch time: 02:33am
Temperature - Air: 500F Concrete: 740F
Truck No: 1067 Ticket No: 88055996
Air Content: 2.8% Unit Weight (pct): NA
Overall Placement Location:
Paving - south side of building 2 from 5'-160' south, 0'-220' east from southwest corner,
east side of (continue)
Sample Location:
20' south, 20' east from southwest corner of building 2
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12"
Cylinder Maximum Compressive
Marked Date Age Diameter Area Load Strength Fracture
Set No. Tested (days) (in) (in") (Ibs) (psi) Type
-
1 1 11/08/2007 7 6.00 28.27 67,640 2,390 Shear
1 2 11/29/2007 28 6.00 28.27 1 09,150 3,860 Cone/Split
1 3 11/29/2007 28 6.00 28.27 111 ,080 3,930 Cone/Split
Average 3,890
1 4 12/27/2007 56
Remarks: building 2 from 0'-150' north, 5'-50' east from southeast corner
Batch plant notified about air test results
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd.
(CH/ED) Page 1 of 6
Rone En2~
Client: Transwestern Commercial Services
5001 Spring Valley
Dallas, TX 75244
8908 Ambassador Row, Dallas, TX 75247
7701 W Little York, Ste 600, Houston, TX 77040
4421 Freidrlch, Ste 195, Austin, TX 78744
Corporate Phone: (214) 630-9745
Report of Concrete Compressive Strength Test
Report No.: 303891
Project No.: 0712786
Date of Service: 11/01/2007
Report Date: 12/11/2007
Project: Gateway Business Center
Coppell, Texas
Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples
back to the laboratory for curing and testing in accordance with applicable standards.
PROJECT DATA
Contractor: Constructors & Associates
Concrete Supplier: Redi Mix
Plant: 88
Specification Requirements
Strength: 3,600 psi @ 28 days
Slump (in.): 3" - 5"
Air (%): 3% - 6%
Test Method: ASTM C-172
ASTM C-31 (except 10.1 .2)
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-138
ASTM C-39
Measured
Slump
(inches)
5.0
Mix Design 1.0.: 23601524
Placement Date: 11/01/2007
Weather Conditions: Calm, clear
Time Sampled: 06:08am Batch time: 05:21 am
Temperature - Air: 520F Concrete: 740F
Truck No: 1245 Ticket No: 88056010
Air Content: 5.5% Unit Weight (pet): NA
Overall Placement Location:
Paving _ south side of building 2 from 5'-160' south, 0'-220' east from southwest corner,
east side of (continue)
Sample Location:
110' south, 100' esat from southwest corner of building 2
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12"
Cylinder Maximum Compressive
Marked Date Age Diameter Area Load Strength Fracture
Set No. Tested (days) (in) (in') (Ibs) (psi) Type
2 1 11/08/2007 7 6.00 28.27 69,660 2,460 Shear
2 2 11/29/2007 28 6.00 28.27 124,150 4,390 Cone/Split
2 3 11/29/2007 28 6.00 28.27 120,010 4,240 Cone/Split
Average 4,320
2 4 12/27/2007 56
Remarks: building 2 from 0'-150' north, 5'-50' east from southeast corner
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, etc.) or any other feature of similar subject mailer provided by persons or conditions over which we have no control. Our lellers and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd.
(CH/ED) Page 2 of 6
Rone Eni=a
Client: Transwestern Commercial Services
5001 Spring Valley
Dallas, TX 75244
8908 Ambassador Row, Dallas, TX 75247
7701 W Little York, Ste 600, Houston, TX 77040
4421 Freldrich, Ste 195, Austin, TX 78744
Corporate Phone: (214) 630-9745
Report of Concrete Compressive Strength Test
Report No.: 303891
Project No.: 0712786
Date of Service: 11/01/2007
Report Date: 12/11/2007
Project: Gateway Business Center
Coppell, Texas
Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples
back to the laboratory for curing and testing in accordance with applicable standards.
PROJECT DATA
Contractor: Constructors & Associates
Concrete Supplier: Redi Mix
Plant: 88
Specification Requirements
Strength: 3,600 psi @ 28 days
Slump (in.): 3" - 5"
Air (%): 3% - 6%
Test Method: ASTM C-172
ASTM C-31 (except 10.1.2)
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-138
ASTM C-39
Measured
Slump
(inches)
4.5
Mix Design 1.0.: 23601524
Placement Date: 11/01/2007
Weather Conditions: Calm, clear
Time Sampled: 07:09am Batch time: 06:29am
Temperature - Air: 470F Concrete: 720F
Truck No: 1090 Ticket No: 88056021
Air Content: 3.8% Unit Weight (pet): NA
Overall Placement Location:
Paving - south side of building 2 from 5'-160' south, 0'-220' east from southwest corner,
east side of (continue)
Sample Location:
90' south, 30' east from southeast corner of building 2
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12"
Cylinder Maximum Compressive
Marked Date Age Diameter Area Load Strength Fracture
Set No. Tested (days) (in) (in') (Ibs) (psi) Type
3 1 11/08/2007 7 6.00 28.27 81,330 2,880 Cone/Split
3 2 11/29/2007 28 6.00 28.27 116,170 4,110 Cone/Split
3 3 11/29/2007 28 6.00 28.27 114,310 4,040 Cone/Split
Average 4,080
3 4 12/27/2007 56
Remarks: building 2 from 0'-150' north, 5'-50' east from southeast corner
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, LId.
(CH/ED) Page 3 of 6
Rone Eni==
Client:
Transwestern Commercial Services
5001 Spring Valley
Dallas, TX 75244
8908 Ambassador Row, Dallas, TX 75247
7701 W Little York, Ste 600, Houston, TX 77040
4421 Freldrlch, Ste 195, Austin, TX 78744
Corporate Phone: (214) 630-9745
Report of Concrete Compressive Strength Test
Report No.: 303891
Project No.: 0712786
Date of Service: 11/01/2007
Report Date: 12/11/2007
Project: Gateway Business Center
Coppell, Texas
Se rvices: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples
back to the laboratory for curing and testing in accordance with applicable standards.
PROJECT DATA
Contractor: Constructors & Associates
Concrete Supplier: Redi Mix
Plant: 88
Specification Requirements
Strength: 3,600 psi @ 28 days
Slump (in.): 3" - 5"
Air (%): 3% - 6%
Test Method: ASTM C-172
ASTM C-31 (except 10.1.2)
ASTM C-143
ASTM C-231
ASTM C-1 064
ASTM C-138
ASTM C-39
Measured
Slump
(inches)
4.0
Mix Design 1.0.: 23601524
Placement Date: 11/01/2007
Weather Conditions: Calm, clear
Time Sampled: 08:48am Batch time: 07:54am
Temperature - Air: 510F Concrete: 740F
Truck No: 1337 Ticket No: 88056034
Air Content: 3.1 % Unit Weight (pet): NA
Overall Placement Location:
Paving _ south side of building 2 from 5'-160' south, 0'-220' east from southwest corner,
east side of (continue)
Sample Location:
3D' south, 40' east from southeast corner of building 2
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12"
Cylinder Maximum Compressive
Marked Date Age Diameter Area Load Strength Fracture
Set No. Tested (days) (in) (in') (Ibs) (psi) Type
4 1 11/08/2007 7 6.00 28.27 103,010 3,640 Cone/Split
4 2 11/29/2007 28 6.00 28.27 130,390 4,610 Cone/Split
4 3 11/29/2007 28 6.00 28.27 137,240 4,850 Cone/Split
Average 4,730
4 4 12/27/2007 56
RemarkS: building 2 from 0'-150' north, 5'-50' east from southeast corner
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition. appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd.
(CH/ED) Page 4 of 6
Rone Eni==
Client: Transwestem Commercial Services
5001 Spring Valley
Dallas, TX 75244
8908 Ambassador Row, Dallas, TX 75247
7701 W Little York, Ste 600, Houston, TX 77040
4421 Freidrlch, Ste 195, Austin, TX 78744
Corporate Phone: (214) 630-9745
Report of Concrete Compressive Strength Test
Report No.: 303891
Project No.: 0712786
Date of Service: 11/01/2007
Report Date: 12/11/2007
Project: Gateway Business Center
Coppell, Texas
Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples
back to the laboratory for curing and testing in accordance with applicable standards.
PROJECT DATA
Contractor: Constructors & Associates
Concrete Supplier: Redi Mix
Plant: 88
Specification Requirements
Strength: 3,600 psi @ 28 days
Slump (in.): 3" - 5"
Air (%): 3% - 6%
Test Method: ASTM C-172
ASTM C-31 (except 10.1.2)
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-138
ASTM C-39
Measured
Slump
(inches)
4.5
Mix Design I.D.: 23601524
Placement Date: 11/01/2007
Weather Conditions: Calm, clear
Time Sampled: 10:36am Batch time: 09:15am
Temperature - Air: 580F Concrete: 740F
Truck No: 1245 Ticket No: 88056051
Air Content: 4.6% Unit Weight (pct): NA
Overall Placement Location:
Paving - south side of building 2 from 5'-160' south, 0'-220' east from southwest corner,
east side of (continue)
Sample Location:
70' north, 30' east from southeast corner of building 2
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12"
Cylinder Maximum Compressive
Marked Date Age Diameter Area Load Strength Fracture
Set No. Tested (days) (in) (in') (Ibs) (psi) Type
5 1 11/08/2007 7 6.00 28.27 71,740 2,540 Shear
5 2 11/29/2007 28 6.00 28.27 124,210 4,390 Cone/Split
5 3 11/29/2007 28 6.00 28.27 122,420 4,330 Cone/Split
Average 4,360
5 4 12/27/2007 56
Remarks: building 2 from 0'-150' north, 5'-50' east from southeast corner
Water added at site: 30 gallons
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, etc.) or any other feature of similar subjecl mailer provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full withoulthe written approval of Rone Engineering Services, LId.
(CHIED) Page 5 of 6
Rone Ene==
Client: Transwestern Commercial Services
5001 Spring Valley
Dallas, TX 75244
8908 Ambassador Row, Dallas, TX 75247
7701 W Little York, Ste 600, Houston, TX 77040
4421 Freldrich, Ste 195, Austin, TX 78744
Corporate Phone: (214) 630-9745
Report of Concrete Compressive Strength Test
Report No.: 301474
Project No.: 0712786
Date of Service: 10/09/2007
Report Date: 12/11/2007
Project: Gateway Business Center
Coppell, Texas
Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples
back to the laboratory for curing and testing in accordance with applicable standards.
Contractor: Constructors & Associates
Concrete Supplier: Redi Mix
Plant: 259
Specification Requirements
Strength: 3,500 psi @ 28 days
Slump (in.): 4" - 6"
Air (%): 2% - 4%
Test Method: ASTM C-172
ASTM C-31 (except 10.1.2)
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-138
ASTM C-39
PROJECT DATA
Mix Design I.D.: 23501501
Placement Date: 10/09/2007
Weather Conditions: Clear
Time Sampled: 03:10am
Temperature - Air: 710F
Truck No: 1350
Air Content: 2.0%
Overall Placement Location:
Paving - north of building parking lot
Batch time: 02:28am
Concrete: 870F
Ticket No: 59015480
Unit Weight (pct): NA
Measured
Slump
(inches)
5.0
Sample Location:
5' west, 10' south from northeast comer of paving
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12"
Cylinder Maximum Compressive
Marked Date Age Diameter Area Load Strength Fracture
Set No. Tested (days) (in) (in') (Ibs) (psi) Type
-
1 1 10/16/2007 7 6.00 28.27 100,580 3,560 Cone/Split
1 2 11/06/2007 28 6.00 28.27 138,040 4,880 Shear
1 3 11/06/2007 28 6.00 28.27 139,800 4,940 Shear
Average 4,910
1 4 12/04/2007 56 6.00 28.27 1 52,190 5,380 Shear
Remarks: Water added at site: 5 gallons
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd.
(CH/ED) Page 1 of 6
Rone En~==
Client: Transwestern Commercial Services
5001 Spring Valley
Dallas, TX 75244
8908 Ambassador Row, Dallas, TX 75247
7701 W Little York, Ste 600, Houston, TX 77040
4421 Freldrich, Ste 195, Austin, TX 78744
Corporate Phone: (214) 630-9745
Report of Concrete Compressive Strength Test
Report No.: 301474
Project No.: 0712786
Date of Service: 10/09/2007
Report Date: 12/11/2007
Project: Gateway Business Center
Coppell, Texas
Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples
back to the laboratory for curing and testing in accordance with applicable standards.
PROJECT DATA
Contractor: Constructors & Associates
Concrete Supplier: Redi Mix
Plant: 259
Specification Requirements
Strength: 3,500 psi @ 28 days
Slump (in.): 4" - 6"
Air (%): 2% - 4%
Test Method: ASTM C-172
ASTM C-31 (except 10.1.2)
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-138
ASTM C-39
Mix Design 1.0.: 23501501
Placement Date: 10/09/2007
Weather Conditions: Clear
Time Sampled: 05:20am
Temperature - Air: 710F
Truck No: 1347
Air Content: 2.2%
Overall Placement Location:
Paving - north of building parking lot
Measured
Slump
(inches)
5.5
Batch time: 04:33am
Concrete: 880F
Ticket No: 59015494
Unit Weight (pet): NA
Sample Location:
100' west, 15' north from southeast corner of paving
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12"
Cylinder Maximum Compressive
Marked Date Age Diameter Area Load Strength Fracture
Set No. Tested (days) (in) (in") (Ibs) (psi) Type
- -
2 1 1 0/16/2007 7 6.00 28.27 91,450 3,230 Cone/Shear
2 2 11/06/2007 28 6.00 28.27 133,930 4,740 Cone/Split
2 3 11/06/2007 28 6.00 28.27 109,350 3,870 Cone/Split
Average 4,300
2 4 12/04/2007 56 6.00 28.27 142,270 5,030 Shear
Remarks: Water added at site: 5 gallons
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd.
(CH/ED) Page 2 of 6
Rone Eni~
Client: Transwestem Commercial Services
5001 Spring Valley
Dallas, TX 75244
8908 Ambassador Row, Dallas, TX 75247
7701 W Little York, ste 600, Houston, TX 77040
4421 Freldrich, ste 195, Austin, TX 78744
Corporate Phone: (214) 630-9745
Report of Concrete Compressive Strength Test
Report No.: 301474
Project No.: 0712786
Date of Service: 10/09/2007
Report Date: 12/11/2007
Project: Gateway Business Center
Coppell, Texas
Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples
back to the laboratory for curing and testing in accordance with applicable standards.
PROJECT DATA
Contractor: Constructors & Associates
Concrete Supplier: Redi Mix
Plant: 259
Specification Requirements
Strength: 3,500 psi @ 28 days
Slump (in.): 4" - 6"
Air (%): 2% - 4%
Test Method: ASTM C-172
ASTM C-31 (except 10.1.2)
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-138
ASTM C-39
Mix Design 1.0.: 23501501
Placement Date: 10/09/2007
Weather Conditions: Clear
Time Sampled: 07:30am
Temperature - Air: 710F
Truck No: 1307
Air Content: 2.0%
Overall Placement Location:
Paving - north of building parking lot
Measured
Slump
(inches)
6.0
Batch time: 06:01 am
Concrete: 870F
Ticket No: 53015501
Unit Weight (pet): NA
Sample Location:
200' west, 10' south from northeast corner of paving
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12"
Cylinder Maximum Compressive
Marked Date Age Diameter Area Load Strength Fracture
Set No. Tested (days) (in) (in") (Ibs) (psi) Type
- -
3 1 10/16/2007 7 6.00 28.27 103,300 3,650 Cone/Split
3 2 11/06/2007 28 6.00 28.27 125,160 4,430 Shear
3 3 11/06/2007 28 6.00 28.27 134,880 4,770 Shear
Average 4,600
3 4 12/04/2007 56 6.00 28.27 150,550 5,320 Shear
Remarks: Water added at site: 5 gallons
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition. appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, LId.
(CH/ED) Page 3 of 6
Rone Eni=::;
Client: Transwestern Commercial Services
5001 Spring Valley
Dallas, TX 75244
8908 Ambassador Row, Dallas, TX 75247
7701 W Little York, Ste 600, Houston, TX 77040
4421 Freidrich, Ste 195, Austin, TX 78744
Corporate Phone: (214) 630-9745
Report of Concrete Compressive Strength Test
Report No.: 301474
Project No.: 0712786
Date of Service: 10/09/2007
Report Date: 12/11/2007
Project: Gateway Business Center
Coppell, Texas
Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples
back to the laboratory for curing and testing in accordance with applicable standards.
PROJECT DATA
Contractor: Constructors & Associates
Concrete Supplier: Redi Mix
Plant: 259
Specification Requirements
Strength: 3,500 psi @ 28 days
Slump (in.): 4" - 6"
Air (%): 2% - 4%
Test Method: ASTM C-172
ASTM C-31 (except 10.1.2)
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-138
ASTM C-39
Mix Design 1.0.: 23501501
Placement Date: 10/09/2007
Weather Conditions: Clear
Time Sampled: 09:30am
Temperature - Air: 750F
Truck No: 1257
Air Content: 2.2%
Overall Placement Location:
Paving - north of building parking lot
Measu red
Slump
(inches)
5.5
Batch time: 08:28am
Concrete: 880F
Ticket No: 59015523
Unit Weight (pet): NA
Sample Location:
60' east, 10' south from northwest corner of paving
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12"
Cylinder Maximum Compressive
Marked Date Age Diameter Area Load Strength Fracture
Set No. Tested (days) (in) (in') (Ibs) (psi) Type
- -
4 1 1 0/16/2007 7 6.00 28.27 103,260 3,650 Cone/Split
4 2 11/06/2007 28 6.00 28.27 132,410 4,680 Cone/Split
4 3 11/06/2007 28 6.00 28.27 128,900 4,560 Shear
Average 4,620
4 4 12/04/2007 56 6.00 28.27 150,790 5,330 Shear
Remarks: Water added at site: 5 gallons
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd.
(CHIED) Page 4 of 6
Rone Eni==
Client: Transwestern Commercial Services
5001 Spring Valley
Dallas, TX 75244
8908 Ambassador Row, Dallas, TX 75247
7701 W Little York, Ste 600, Houston, TX 77040
4421 Freldrich, Ste 195, Austin, TX 78744
Corporate Phone: (214) 630-9745
Report of Concrete Compressive Strength Test
Report No.: 301474
Project No.: 0712786
Date of Service: 10/09/2007
Report Date: 12/11/2007
Project: Gateway Business Center
Coppell, Texas
Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples
back to the laboratory for curing and testing in accordance with applicable standards.
Contractor: Constructors & Associates
Concrete Supplier: Redi Mix
Plant: 259
Specification Requirements
Strength: 3,500 psi @ 28 days
Slump (in.): 4" - 6"
Air (%): 2% - 4%
Test Method: ASTM C-172
ASTM C-31 (except 10.1.2)
ASTM C-143
ASTM C-231
ASTM C-1 064
ASTM C-138
ASTM C-39
PROJECT DATA
Mix Design I.D.: 23501501
Placement Date: 10/09/2007
Weather Conditions: Clear
Time Sampled: 09:50am
Temperature - Air: 740F
Truck No: 1264
Air Content: 2.4%
Overall Placement Location:
Paving - north of building parking lot
Batch time: 09:10am
Concrete: 880F
Ticket No: 59015535
Unit Weight (pet): NA
Measured
Slump
(inches)
5.0
Sample Location:
30' east, 5' north from southwest corner of paving
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12"
Cylinder Maximum Compressive
Marked Date Age Diameter Area Load Strength Fracture
Set No. Tested (days) (in) (in') (Ibs) (psi) Type
-
5 1 10/16/2007 7 6.00 28.27 95,240 3,370 Cone/Shear
5 2 11/06/2007 28 6.00 28.27 125,040 4,420 Cone/Split
5 3 11/06/2007 28 6.00 28.27 125,620 4,440 Cone/Shear
Average 4,430
5 4 12/04/2007 56 6.00 28.27 145,720 5,150 Cone/Split
Remarks: Water added at site: 30 gallons
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, etc.) or any other feature of similar subject matter provided by persons or cond~ions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd.
(CH/ED) Page 5 of 6
Rone Eni==
Client: Transwestern Commercial Services
5001 Spring Valley
Dallas, TX 75244
8908 Ambassador Row, Dallas, TX 75247
7701 W Little York, Ste 600, Houston, TX 77040
4421 Freidrlch, Ste 195, Austin, TX 78744
Corporate Phone: (214) 630-9745
Report of Concrete Compressive Strength Test
Report No.: 301781
Project No.: 0712786
Date of Service: 10/11/2007
Report Date: 12/11/2007
Project: Gateway Business Center
Coppell, Texas
Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples
back to the laboratory for curing and testing in accordance with applicable standards.
PROJECT DATA
Contractor: Constructors & Associates
Concrete Supplier: Redi Mix
Plant: 136
Specification Requirements
Strength: 3,600 psi @ 28 days
Slump (in.): 4" - 6"
Air (%): 4% - 6%
Test Method: ASTM C-172
ASTM C-31 (except 10.1.2)
ASTM C-143
ASTM C-231
ASTM C-1 064
ASTM C-138
ASTM C-39
Measured
Slump
(inches)
6.0
Mix Design 1.0.: 23601524
Placement Date: 10/11/2007
Weather Conditions: Clear, calm
Time Sampled: 03:36am Batch time: 02:34am
Temperature - Air: 600F Concrete: 770F
Truck No: 1035 Ticket No: 13699228
Air Content: 4.0% Unit Weight (pet): NA
Overall Placement Location:
Paving - building 1 on south side and west side - parking spaces and driveway
Sample Location:
Grid line Building 1, A 1 50' west, 50' north
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12"
Cylinder Maximum Compressive
Marked Date Age Diameter Area Load Strength Fracture
Set No. Tested (days) (in) (in') (Ibs) (psi) Type
1 1 10/18/2007 7 6.00 28.27 100,280 3,550 Shear
1 2 11/08/2007 28 6.00 28.27 131,690 4,660 Cone/Split
1 3 11/08/2007 28 6.00 28.27 135,220 4,780 Cone/Split
Average 4,720
1 4 12/06/2007 56 6.00 28.27 142,730 5,050 Shear
LIMIT ATfONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Lid.
(DMlED) Page 1 of 5
Rone Eni==
Client: Transwestern Commercial Services
5001 Spring Valley
Dallas, TX 75244
8908 Ambassador Row, Dallas, TX 75247
7701 W Little York, Ste 600, Houston, TX 77040
4421 Freidrich, Ste 195, Austin, TX 78744
Corporate Phone: (214) 630-9745
Report of Concrete Compressive Strength Test
Report No.: 301781
Project No.: 0712786
Date of Service: 10/11/2007
Report Date: 12/11/2007
Project: Gateway Business Center
Coppell, Texas
Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples
back to the laboratory for curing and testing in accordance with applicable standards.
PROJECT DATA
Contractor: Constructors & Associates
Concrete Supplier: Redi Mix
Plant: 136
Specification Requirements
Strength: 3,600 psi @ 28 days
Slump (in.): 4" - 6"
Air (%): 4% - 6%
Test Method: ASTM C-172
ASTM C-31 (except 10.1.2)
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-138
ASTM C-39
Batch time: 04:11am
Concrete: 800F
Ticket No: 13699241
Unit Weight (pct): NA
Measured
Slump
(inches)
5.0
Mix Design I.D.: 23601524
Placement Date: 10/11/2007
Weather Conditions: Clear
Time Sampled: 05:10am
Temperature - Air: 600F
Truck No: 1032
Air Content: 3.5%
Overall Placement Location:
Paving - building 1 on south side and west side - parking spaces and driveway
Sample Location:
Grid line Building 1, E3, 50' south
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12"
Cylinder Maximum Compressive
Marked Date Age Diameter Area Load Strength Fracture
Set No. Tested (days) (in) (in") (Ibs) (psi) Type
2 1 1 0/18/2007 7 6.00 28.27 89,100 3,150 Shear
2 2 11/08/2007 28 6.00 28.27 119,850 4,240 Shear
2 3 11/08/2007 28 6.00 28.27 116,680 4,130 Shear
Average 4,180
2 4 12/06/2007 56 6.00 28.27 133,610 4,730 Cone/Split
Remarks: Water added at site: 10 gallons
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, etc.) or any other feature of similar subject mailer provided by persons or conditions over which we have no control. Our lellers and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd.
(DMIED) Page 2 of 5
Rone En~~
Client: Transwestern Commercial Services
5001 Spring Valley
Dallas, TX 75244
8908 Ambassador Row, Dallas, TX 75247
7701 W Little York, Ste 600, Houston, TX 77040
4421 Freidrich, Ste 195, Austin, TX 78744
Corporate Phone: (214) 630-9745
Report of Concrete Compressive Strength Test
Report No.: 301781
Project No.: 0712786
Date of Service: 10/11/2007
Report Date: 12/11/2007
Project: Gateway Business Center
Coppell, Texas
Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples
back to the laboratory for curing and testing in accordance with applicable standards.
PROJECT DATA
Contractor: Constructors & Associates
Concrete Supplier: Redi Mix
Plant: 136
Specification Requirements
Strength: 3,600 psi @ 28 days
Slump (in.): 4" - 6"
Air (%): 4% - 6%
Test Method: ASTM C-172
ASTM C-31 (except 10.1.2)
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-138
ASTM C-39
Batch time: 05:37am
Concrete: 800F
Ticket No: 13699254
Unit Weight (pet): NA
Measured
Slump
(inches)
4.0
Mix Design I.D.: 23601524
Placement Date: 10/11/2007
Weather Conditions: Sunny
Time Sampled: 07:25am
Temperature - Air: 600F
Truck No: 1185
Air Content: 4.0%
Overall Placement Location:
Paving - building 1 on south side and west side - parking spaces and driveway
Sample Location:
Grid line Building 1, E 1, 15' south, 50' west
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12"
Cylinder Maximum Compressive
Marked Date Age Diameter Area Load Strength Fracture
Set No. Tested (days) (in) (in") (Ibs) (psi) Type
-
3 1 10/18/2007 7 6.00 28.27 104,810 3,710 Cone/Split
3 2 11/08/2007 28 6.00 28.27 130,520 4,620 Cone/Split
3 3 11/08/2007 28 6.00 28.27 137,970 4,880 Cone/Split
Average 4,750
3 4 12/06/2007 56 6.00 28.27 153,540 5,430 Shear
LIMiT A TIONS: The lesl results presenled herein were prepared based upon Ihe specific samples provided for lesling. We assume no responsibility for variation in quality
(composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients 10 whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, LId.
(DMIED) Page 3 of 5
Rone Eni=a
Client: Transwestem Commercial Services
5001 Spring Valley
Dallas, TX 75244
8908 Ambassador Row, Dallas, TX 75247
7701 W Little York, Ste 600, Houston, TX n040
4421 Freidrich, Ste 195, Austin, TX 78744
Corporate Phone: (214) 630-9745
Report of Concrete Compressive Strength Test
Report No.: 301781
Project No.: 0712786
Date of Service: 10/11/2007
Report Date: 12/11/2007
Project: Gateway Business Center
Coppell, Texas
Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples
back to the laboratory for curing and testing in accordance with applicable standards.
PROJECT DATA
Contractor: Constructors & Associates
Concrete Supplier: Redi Mix
Plant: 136
Specification Requirements
Strength: 3,600 psi @ 28 days
Slump (in.): 4" - 6"
Air (%): 4% - 6%
Test Method: ASTM C-172
ASTM C-31 (except 10.1.2)
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-138
ASTM C-39
Batch time:
Concrete: 79DF
Ticket No: 13699281
Unit Weight (pet): NA
Measured
Slump
(inches)
4.75
Mix Design 1.0.: 23601524
Placement Date: 10/11/2007
Weather Conditions: Sunny
Time Sampled: I 09:00am
Temperature - Air: 69DF
Truck No: 1033
Air Content: 5.0%
Overall Placement Location:
Paving - building 1 on south side and west side - parking spaces and driveway
Sample Location:
Grid line Building 1 , E6, 30' south
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12"
Cylinder Maximum Compressive
Marked Date Age Diameter Area Load Strength Fracture
Set No. Tested (days) (in) (in') (Ibs) (psi) Type
4 1 10/18/2007 7 6.00 28.27 87,700 3,100 Cone/Split
4 2 11/08/2007 28 6.00 28.27 120,990 4,280 Cone/Split
4 3 11/08/2007 28 6.00 28.27 113,410 4,010 Cone/Split
Average 4,150
4 4 12/06/2007 56 6.00 28.27 130,630 4,620 Shear
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd.
(DMIED) Page 4 of 5
Rone En~~
Client: Transwestern Commercial Services
5001 Spring Valley
Dallas, TX 75244
8908 Ambassador Row, Dallas, TX 75247
7701 W Little York, Ste 600, Houston, TX 77040
4421 Freidrich, Ste 195, Austin, TX 78744
Corporate Phone: (214) 630-9745
Report of Concrete Compressive Strength Test
Report No.: 304062
Project No.: 0712786
Date of Service: 11/02/2007
Report Date: 12/11/2007
Project: Gateway Business Center
Coppell, Texas
Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples
back to the laboratory for curing and testing in accordance with applicable standards.
PROJECT DATA
Contractor: Constructors & Associates
Concrete Supplier: Redi Mix
Plant: 88
Specification Requirements
Strength: 3,600 psi @ 28 days
Slump (in.): 3" - 5"
Air (%): 4% - 6%
Test Method: ASTM C-172
ASTM C-31 (except 10.1.2)
ASTM C-143
ASTM C-231
ASTM C-1 064
ASTM C-138
ASTM C-39
Mix Design I.D.: 23601524
Placement Date: 11/02/2007
Weather Conditions: Cloudy
Time Sampled: 04:30am
Temperature - Air: 600F
Truck No: 1070
Air Content: 2.5%
Overall Placement Location:
Fire lane and park paving on north side of building 2
Measured
Slump
(inches)
8.0
Batch time: 04:09am
Concrete: 710F
Ticket No: 88056117
Unit Weight (pet): NA
Sample Location:
45' west, 40' north from northwest corner of building 2
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12"
Cylinder Maximum Compressive
Marked Date Age Diameter Area Load Strength Fracture
Set No. Tested (days) (in) (in') (Ibs) (psi) Type
1 1 11/09/2007 7 6.00 28.27 71,700 2,540 Cone/Split
1 2 11/30/2007 28 6.00 28.27 100,570 3,560 Cone/Split
1 3 11/30/2007 28 6.00 28.27 94,070 3,330 Cone/Split
Average 3,440 *
1 4 12/28/2007 56
* Does not comply with specified strength
Remarks: Water added at site: 15 gallons
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, LId.
(CH/KW) Page 1 of 5