Loading...
Duke Lesley 1A-LR071227 Rone Engineering " 8908 Ambassador Row, Dallas, TX 75247 7701 W Little Yor~., Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 Report of Reinforcing Steel Inspection Report No.: 308692 Project No.: 0713408 Date of Service: 12/20/2007 Report Date: 12/27/2007 Project: Point West VI Coppell, Texas Services: Reinforcing Steel Inspection Report of Inspection Locations and Items Inspected: Paving, north middle section, pour 4 and northwest corner section towards middle, pour 5 Item s Inspected: Conforming Non Items Inspected: Co nfo rm ing Non Item sins pected: Co nfo rm ing Non Co nfo rming Co nfo rm ing Co nfo rm ing P lacing Drawings Bar Length Column Ties Properly Approved x and Shape x Tied and Spaced NA Bar Size x Proper B ar Placement x Stirrup Spacing NA Bar Grade x Pro perly Tied x Stirrup Type NA Bars Clean x Dowel Bars in Place x Lapped Splices x Form Clean x Pro per Bar Suppa rts x CornerBars NA Number of Bars x P roper Cover x Mechanical Splices NA Discrepancies f Comments: 1. Remove mud/soil from placement area. 2. Remove trash. 3. Tie down steel at various locations. 4. Adjust dowel bars. 5. Add chairs. 6. Adjust steel at curve. The discrepancies noted above were corrected at the time of inspection. Technician: Jose Villanueva Started: 02:00pm Report Distribution: Orig: Duke Construction, LP (Dallas, TX) Attn: Mr. Emmit Coots (1-ec copy) 1-cc Pacheco Koch Consulting Engineers Attn: Mr. Jack Evans 1-cc City of Coppell Attn: Mr. Larry Davis 1-cc City of Coppell Attn: Mr. Lee Stone Finished: 03:45pm Rone Engineering P-~~ K. Scott Watson, AET Project Manager LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (TM/KW) Page 1 of 1 Rone Engineering . 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 Report of Reinforcing Steel Inspection Report No.: 308890 Project No.: 0713408 Date of Service: 12/21/2007 Report Date: 12/27/2007 Project: Point West VI Coppell, Texas Services: Reinforcing Steel Inspection Report of Inspection Locations and Items Inspected: Paving and north side of building from northwest existing paving toward northeast existing paving Item s Inspected: Conforming Non Items Inspected: Conforming Non Items Inspected: Conlo rm ing Non Co nforming Conforming Conform Ing P lacing Drawings Bar Length Column Ties Properly Approved x and Shape x Tied and Spaced NA Bar Size x P fO per 8 ar P lacem ent x Stirrup Spacing NA Bar Grade x Pro perly Tied x Stirrup Type NA Bars Clean x Dowel Bars in Place x Lapped Splices x Form Clean x Pro per B ar Suppo rts x CornerBars NA Num ber of Bars x Proper Cover x Mechanical Splices NA Discrepancies / Comments: 1. Remove trash. 2. Tie down steel at various locations. 3. Add chairs. The discrepancies noted above were corrected at the time of inspection. Technician: Jose Villanueva Started: 02:15pm Report Distribution: Orig: Duke Construction, LP (Dallas, TX) Attn: Mr. Emmit Coots (1-ec copy) 1-cc Pacheco Koch Consulting Engineers Attn: Mr. Jack Evans 1-cc City of Coppell Attn: Mr. Larry Davis 1-cc City of Coppell Attn: Mr. Lee Stone Finished: 04:45pm Rone Engineering ~~~ K. Scott Watson, AET Project Manager LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (TM/KW) Page 1 of 1