Duke Lesley 1A-LR080102 Rone Engineering . Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 308783 Project No.: 0713408 Date of Service: 12/21/2007 Report Date: 01/02/2008 Project: Point West VI Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA Contractor: Duke Construction, LP Concrete Supplier: Potter Concrete Plant: On site Specification Requirements Strength: 4,000 psi @ 28 days Slump (in.): 4" - 6" Air (%): 4% - 6% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 Batch time: Concrete: 550F Ticket No: NA Unit Weight (pet): NA Measured Slump (inches) 5.0 Mix Design 1.0.: 7753 Placement Date: 12/21/2007 Weather Conditions: Clear Time Sampled: 03:15am Temperature - Air: 400F Truck No: 142 Air Content: 4.5% Overall Placement Location: Paving - parking spaces and driveway on north side of building and northwest corner Sample Location: 160' north from grid line A/17.3 REPORT OF TESTS Cylinder Marked Date Set No. Tested 1 1 12/28/2007 1 2 01/18/2008 1 3 01/18/2008 1 4 02/15/2008 Age (days) 7 Diameter (in) 6.00 28 28 56 0EJ ~~ DId E] DO D Type 1 Type 2 Type 3 Type 4 Type 5 Concrete Compressive Cylinder 6" x 12" Maximum Load (Ibs) 116,470 Compressive Strength (psi) 4,120 Fracture Type Type2 Area (in2) 28.27 Type 6 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (KW/KW) Page 1 of 10 Rone Engineering . Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 308783 Project No.: 0713408 Date of Service: 12/21/2007 Report Date: 01/02/2008 Project: Point West VI Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA Contractor: Duke Construction, LP Concrete Supplier: Potter Concrete Plant: On site Specification Requirements Strength: 4,000 psi @ 28 days Slump (in.): 4" - 6" Air (%): 4% - 6% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 Batch time: Concrete: 520F Ticket No: NA Unit Weight (pcf): NA Measured Slump (inches) 5.75 Mix Design 1.0.: 7753 Placement Date: 12/21/2007 Weather Conditions: Clear Time Sampled: 05:15am Temperature - Air: 420F Truck No: 137 Air Content: 4.7% Overall Placement Location: Paving - parking spaces and driveway on north side of building and northwest corner Sample Location: 120' north from grid line N16.3 REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Fracture Set No. Tested (days) (in) (in') (Ibs) (psi) Type 2 1 12/28/2007 7 6.00 28.27 105,570 3,730 Type5 2 2 01/18/2008 28 2 3 01/18/2008 28 2 4 02/15/2008 56 [3]tJ ~[g [)IE rsJ DO D Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (KWIKW) Page 2 of 10 Rone Engineering . Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrlch, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 308783 Project No.: 0713408 Date of Service: 12/21/2007 Report Date: 01/02/2008 Project: Point West VI Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA Contractor: Duke Construction, LP Concrete Supplier: Potter Concrete Plant: On site Specification Requirements Strength: 4,000 psi @ 28 days Slump (in.): 4" - 6" Air (%): 4% - 6% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 Measured Slump (inches) 5.25 Mix Design I.D.: 7753 Placement Date: 12/21/2007 Weather Conditions: Clear, windy Time Sampled: 07:00am Batch time: Temperature - Air: 550F Concrete: 580F Truck No: 136 Ticket No: NA Air Content: 5.7% Unit Weight (pet): NA Overall Placement Location: Paving - parking spaces and driveway on north side of building and northwest corner Sample Location: 100' north from grid line A/6.3 REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Fracture Set No. Tested (days) (in) (in2) (Ibs) (psi) Type 3 1 12/28/2007 7 6.00 28.27 95,890 3,390 Type5 3 2 01/18/2008 28 3 3 01/18/2008 28 3 4 02/15/2008 56 ~E3 ~[g ~ ~ DO D Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, ltd. (KW/KW) Page 4 of 10 Rone Engineering . Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 308783 Project No.: 0713408 Date of Service: 12/21/2007 Report Date: 01/02/2008 Project: Point West VI Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA Contractor: Duke Construction, LP Concrete Supplier: Potter Concrete Plant: On site Specification Requirements Strength: 4,000 psi @ 28 days Slump (in.): 4" - 6" Air (%): 4% - 6% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1 064 ASTM C-138 ASTM C-39 Measured Slump (inches) 5.5 Mix Design I.D.: 7753 Placement Date: 12/21/2007 Weather Conditions: Clear, windy Time Sampled: 08:34am Batch time: Temperature - Air: 450F Concrete: 550F Truck No: 137 Ticket No: NA Air Content: 5.5% Unit Weight (pet): NA Overall Placement Location: Paving - parking spaces and driveway on north side of building and northwest corner Sample Location: 160' north from grid line A/4.7 REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Fracture Set No. Tested (days) (in) (in') (Ibs) (psi) Type 4 1 12/28/2007 7 6.00 28.27 95,130 3,360 Type5 4 2 01/18/2008 28 4 3 01/18/2008 28 4 4 02/15/2008 56 0t3 [2][9 51] E;J DO D Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (KWIKW) Page 6 of 10 Rone Engineering . Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 308783 Project No.: 0713408 Date of Service: 12/21/2007 Report Date: 01/02/2008 Project: Point West VI Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA Contractor: Duke Construction, LP Concrete Supplier: Potter Concrete ~a~: Ons~ Specification Requirements Strength: 4,000 psi @ 28 days Slump (in.): 4" - 6" Air (%): 4% - 6% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 Measured Slump (inches) 5.25 Mix Design I.D.: 7753 Placement Date: 12/21/2007 Weather Conditions: Clear, windy Time Sampled: Batch time: Temperature - Air: 550F Concrete: 580F Truck No: 137 Ticket No: NA Air Content: 5.7% Unit Weight (pcf): NA Overall Placement Location: Paving - parking spaces and driveway on north side of building and northwest corner Sample Location: 120' north from grid line AJ1. 7 REPORT OF TESTS Cylinder Marked Date Set No. Tested 5 1 12/28/2007 5 2 01/18/2008 5 3 01/18/2008 5 4 02/15/2008 Age (days) 7 Diameter (in) 6.00 28 28 56 0L3 ~[g Ern bJ DO D Type 1 Type 2 Type 3 Type 4 Type 5 Concrete Compressive Cylinder 6" x 12" Maximum Load (Ibs) 91,510 Compressive Strength (psi) 3,240 Fracture Type Type2 Area (in') 28.27 Type 6 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (KW/KW) Page 8 of 10 Rone Engineering . Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214)630-9745 Report of Concrete Compressive Strength Test Report No.: 308783 Project No.: 0713408 Date of Service: 12/21/2007 Report Date: 01/02/2008 Project: Point West VI Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA Contractor: Duke Construction, LP Concrete Supplier: Potter Concrete Plant: On site Specification Requirements Strength: 4,000 psi @ 28 days Slump (in.): 4" - 6" Air (%): 4% - 6% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 Measured Slump (inches) 6.0 Mix Design 1.0.: 7753 Placement Date: 12/21/2007 Weather Conditions: Sunny, windy Time Sampled: 11:04am Batch time: Temperature - Air: 600F Concrete: 580F Truck No: 129 Ticket No: NA Air Content: 5.6% Unit Weight (pcf): NA Overall Placement Location: Paving - parking spaces and driveway on north side of building and northwest corner Sam pie Location: 120' north, 70' west from grid line A/1 REPORT OF TESTS Cylinder Marked Date Set No. Tested 6 1 12/28/2007 6 2 01/18/2008 6 3 01/18/2008 6 4 02/15/2008 Age (days) 7 Diameter (in) 6.00 28 28 56 ~E3 ~0 Krn lSJ DO D Type 1 Type 2 Type 3 Type 4 Type 5 Concrete Compressive Cylinder 6" x 12" Maximum Load (Ibs) 1 03, 130 Compressive Strength (psi) 3,650 Fracture Type Type6 Area (in') 28.27 Type 6 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar SUbject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (KWIKW) Page 9 of 10