Duke Lesley 1A-LR080103 Rone Engineering . Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 308966 Project No.: 0713408 Date of Service: 12/22/2007 Report Date: 01/03/2008 Project: Point West VI Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. Contractor: Duke Construction, LP Concrete Supplier: Potter Concrete Plant: On site Specification Requirements Strength: 4,000 psi @ 28 days Slump (in.): 4" - 6" Air (%): 4% - 6% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 PROJECT OAT A Mix Design 1.0.: 7753 Placement Date: 12/22/2007 Weather Conditions: Clear Time Sampled: 03:30am Temperature - Air: 550F Truck No: 109 Air Content: 5.8% Overall Placement Location: Paving, driveway, east side of project Batch time: Concrete: 580F Ticket No: NA Unit Weight (pcf): NA Measured Slump (inches) 5.0 Sample Location: 100' north, 30' east from grid lines N42 REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Fracture Set No. Tested (days) (in) (in') (Ibs) (psi) Type 1 1 12/29/2007 7 6.00 28.27 116,140 4,110 Type2 2 01/19/2008 28 3 01/19/2008 28 1 4 02/16/2008 56 ~~ ~Q;J ~ ~ DO D Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition. appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (KW/KW) Page 1 of 10 Rone Engineering . Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrlch, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 308966 Project No.: 0713408 Date of Service: 12/22/2007 Report Date: 01/03/2008 Project: Point West VI Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. Contractor: Duke Construction, LP Concrete Supplier: Potter Concrete Plant: On site Specification Requirements Strength: 4,000 psi @ 28 days Slump (in.): 4" - 6" Air (%): 4% - 6% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 PROJECT DATA Mix Design 1.0.: 7753 Placement Date: 12/22/2007 Weather Conditions: Clear Time Sampled: 04:57am Temperature - Air: 570F Truck No: 136 Air Content: 5.7% Overall Placement Location: Paving, driveway, east side of project Batch time: Concrete: 580F Ticket No: NA Unit Weight (pcf): NA Measured Slump (inches) 5.75 Sample Location: 55' east from northeast corner of building, grid line A.5/42 REPORT OF TESTS Cylinder Marked Date Set No. Tested 2 1 12/29/2007 2 2 01/19/2008 2 3 01/19/2008 2 4 02/16/2008 Age (days) 7 Diameter (in) 6.00 28 28 56 ~~ ~lQ rnJ ~ DO D Type 1 Type 2 Type 3 Type 4 Type 5 Concrete Compressive Cylinder 6" x 12" Maximum Load (Ibs) 118,270 Compressive Strength (psi) 4,180 Fracture Type Type2 Area (in') 28.27 Type 6 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for vanation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (KW/KW) Page 2 of 10 Rone Engineering . Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214)630-9745 Report of Concrete Compressive Strength Test Report No.: 308966 Project No.: 0713408 Date of Service: 12/22/2007 Report Date: 01/03/2008 Project: Point West VI Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. Contractor: Duke Construction, LP Concrete Supplier: Potter Concrete Plant: On site Specification Requirements Strength: 4,000 psi @ 28 days Slump (in.): 4" - 6" Air (%): 4% - 6% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 PROJECT DATA Mix Design I.D.: 7753 Placement Date: 12/22/2007 Weather Conditions: Clear Time Sampled: 06:00am Temperature - Air: 530F Truck No: 142 Air Content: 5.0% Overall Placement Location: Paving, driveway, east side of project Batch time: Concrete: 570F Ticket No: NA Unit Weight (pet): NA Measured Slump (inches) 5.25 Sample Location: 30' east from grid lines D.7/42 REPORT OF TESTS Cylinder Marked Date Set No. Tested - 3 1 12/29/2007 3 2 01/19/2008 3 3 01/19/2008 3 4 02/16/2008 Age (days) 7 Diameter (in) 6.00 28 28 56 ~rJ ~]l v.,l Type 2 Krn lSJ DO D Type 1 Type 3 Type 4 Type 5 Concrete Compressive Cylinder 6" x 12" Maximum Load (Ibs) 118,490 Compressive Strength (psi) 4,190 Fracture Type Type6 Area (in') 28.27 Type 6 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (KW/KW) Page 4 of 10 Rone Engineering . Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freldrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 308966 Project No.: 0713408 Date of Service: 12/22/2007 Report Date: 01/03/2008 Project: Point West VI Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. Contractor: Duke Construction, LP Concrete Supplier: Potter Concrete Plant: On site Specification Requirements Strength: 4,000 psi @ 28 days Slump (in.): 4" - 6" Air (%): 4% - 6% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1 064 ASTM C-138 ASTM C-39 PROJECT DATA Mix Design I.D.: 7753 Placement Date: 12/22/2007 Weather Conditions: Clear Time Sampled: 08:45am Temperature - Air: 550F Truck No: 137 Air Content: 4.5% Overall Placement Location: Paving, driveway, east side of project Batch time: Concrete: 640F Ticket No: NA Unit Weight (pet): NA Measured Slump (inches) 4.5 Sample Location: 60' east from grid line E1/42 REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Fracture Set No. Tested (days) (in) (in.) (Ibs) (psi) Type - 4 1 12/29/2007 7 6.00 28.27 154,150 5,450 Type2 4 2 01/19/2008 28 4 3 01/19/2008 28 4 4 02/16/2008 56 ~~ ~[g ffi] lSJ DO D Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (KW/KW) Page 5 of 10 Rone Engineering . Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 308966 Project No.: 0713408 Date of Service: 12/22/2007 Report Date: 01/03/2008 Project: Point West VI Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. Contractor: Duke Construction, LP Concrete Supplier: Potter Concrete Plant: On site Specification Requirements Strength: 4,000 psi @ 28 days Slump (in.): 4" - 6" Air (%): 4% - 6% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 PROJECT OAT A Mix Design 1.0.: 7753 Placement Date: 12/22/2007 Weather Conditions: Clear Time Sampled: 10:32am Temperature - Air: 480F Truck No: 137 Air Content: 4.9% Overall Placement Location: Paving, driveway, east side of project Batch time: Concrete: 550F Ticket No: NA Unit Weight (pcf): NA Measured Slump (inches) 4.75 Sample Location: 50' east from grid lines K.1/42 REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Fracture Set No. Tested (days) (in) (in') (Ibs) (psi) Type 5 1 12/29/2007 7 6.00 28.27 139,210 4,920 Type2 5 2 01/19/2008 28 5 3 01/19/2008 28 5 4 02/16/2008 56 ~~ ~[2;] [ill] lS] DO D Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (KW/KW) Page 7 of 10 Rone Engineering . Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 308966 Project No.: 0713408 Date of Service: 12/22/2007 Report Date: 01/03/2008 Project: Point West VI Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. Contractor: Duke Construction, LP Concrete Supplier: Potter Concrete Plant: On site Specification Requirements Strength: 4,000 psi @ 28 days Slump (in.): 4" - 6" Air (%): 4% - 6% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 PROJECT DATA Mix Design I.D.: 7753 Placement Date: 12/22/2007 Weather Conditions: Mostly cloudy, windy Time Sampled: 12:45pm Batch time: Temperature - Air: 450F Concrete: 600F Truck No: 131 Ticket No: NA Air Content: 5.7% Unit Weight (pcf): NA Overall Placement Location: Paving, driveway, east side of project Measured Slump (inches) 5.0 Sample Location: 95' south, 50' east from grid lines U42 REPORT OF TESTS Cylinder Marked Date Set No. Tested 6 1 12/29/2007 6 2 01/19/2008 6 3 01/19/2008 6 4 02/16/2008 Age (days) 7 Diameter (in) 6.00 28 28 56 ~[j ~[2] ~ lSJ DC] D Type 1 Type 2 Type 3 Type 4 Type 5 Concrete Compressive Cylinder 6" x 12" Maximum Load (Ibs) 116,570 Compressive Strength (psi) 4,120 Fracture Type Type2 Area (in') 28.27 Type 6 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (KW/KW) Page 8 of 10