Vista Ridge Retail-CS080207
WINKELMANN & ASSOCIATES, INC.
Concorde on the Creek
6750 Hillcrest Plaza Drive
Suite 100
Dallas, Texas 75230
(972) 490-7090
Fax (972) 490-7099
DISTRIBUTION LIST
DATE: 02/07/08
WAI #: 19985
RE: Vista Ridge Retail
(J'"
Uw.....A, Lots 6 & 7
I Revised Plans
.......
(I hr.)
...........
02-07-08P04:30 RCVD
~,w
1
Enclosed are 10 copies of the revised sheets. Please see the attached list
of changes. Please stamp and get 7 copies to the inspector.
Thanks,
Michael Doggett, PE
Signed:~
Vista Ridge Retail
N.E.C. S.H. 121 & Denton tap Road
Coppell, Texas
Plan Changes
02/07/08
The following revisions have been made from the Original Bid Set. Refer to the
Architects Building Plans for details. These changes are reflected in all sheets with
a plan view.
. 1. Refer to the Cover Sheet:
./a. Revised Sheet Matrix
v b. Added C-4c Highland Drive Decel Lane Plan
2. Refer to the Dimension Control Plan (C-3) sheet:
.... a. Revised width of eastern drive on Highland to 35' wide. Adjusted radii to
accommodate larger truck.
b. Relocated 2 parking places to east side of drive. - ~GE
4. Refer to the Paving Plan (C-4a) sheet:
a. Modified the limits of Heavy Duty and Regular Duty Pavement at the
revised driveways.
5. Refer to the Highland Drive Decel Plan (C-4c) sheet: ('A1,w'l7Vfu.-~ \
a. Added a detailed plan showing construction of a decellane at the western
driveway on to Highland Drive. ____
/rv'f1/pf1) J/Pf-W;ttK ~A.5f3Mtfj1/r
. 6. Refer to the Paving & Civil Details (C-5) sheet:
,.,8. Revised the Highland Drive Driveway Paving Section to include 4,200 psi
concrete. -
7. Refer to the Grading Plan (C-6) sheet:
I a. Revised grading due to driveway modification on Highland Drive.
8. Refer to the Storm Drain Plan (C-9) sheet:
'a. Revised 36" storm drain connection to proposed junction box.
9. Refer to the Storm Drain Profile-Line '1' (C-10) sheet:
o./ti. Revised 36" RCP due to existing 27" Sanitary Sewer proximity. - Cll-~t!- T6 I X
Vb. Tunneling required to connect to proposed junction box.
c. Adjusted Hydraulic Grade Line for City Engineer.
g:\office data\work\ 199\85\Plan Changes 3.doc
10. Refer to the Storm Drain Profile-Line '1' (C-11) sheet:
a. Adjusted Hydraulic Grade Line for City Engineer.
11. Refer to the Erosion Control Plan (C-13) sheet:
a. Adjusted limits of silt fence.