Duke Lesley 2A-LR080201 Rone Engineering . 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Client: Report of Concrete Compressive Strength Test Report No.: 307302 Project No.: 0712932 Date of Service: 12/05/2007 ,/ Report Date: 02/01/2008 Project: Hemisphere's at Point we~ J A ~ ~, Coppell, Texas rL J *"'\.. Services: Obtain samples of fresh concrete at the placement locations, perform required t sting, cast compressive strength samples and bring Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 samples back to the laboratory for curing and testing in accordance with applicable standards. Contractor: Duke Construction, LP Concrete Supplier: Potter Concrete Plant: 10 Specification Requirements Strength: 4,000 psi @ 28 days Slump (in.): 4" - 6" Air (%): 3% - 5% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 PROJECT DATA Mix Design 1.0.: 7753PW Placement Date: 12/05/2007 Weather Conditions: Clear Time Sampled: 03:10am Temperature - Air: 440F Truck No: 101 Air Content: 4.5% Overall Placement Location: Paving, Point West VII Batch time: 02:58am Concrete: 800F Ticket No: 9764 Unit Weight (pet): NA Measured Slump (inches) 5.25 Sample Location: 50' north, 700' east from northwest building corner REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Fracture Set No. Tested (days) (in) (in') (Ibs) (psi) Type 1 1 12/12/2007 7 6.00 28.27 107,150 3,790 Type2 1 2 01/02/2008 28 6.00 28.27 150,930 5,340 Type5 1 3 01/02/2008 28 6.00 28.27 149,400 5,280 Type6 Average 5,310 1 4 01/30/2008 56 6.00 28.27 157,380 5,570 Type2 ~EJ ~Q] [ill] [] DO D Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 /2/II!; (/ f! LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (KW/KW) Page 1 of 8 Rone Engineering . Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (2141630-9745 Report of Concrete Compressive Strength Test Report No.: 307302 Project No.: 0712932 Date of Service: 12/05/2007 Report Date: 02/01/2008 Project: Hemisphere's at Point West Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Set No. Tested (days) (in) (in') (Ibs) (psi) 2 1 12/12/2007 7 6.00 28.27 113,660 4,020 2 2 01/02/2008 28 6.00 28.27 151,270 5,350 2 3 01/02/2008 28 6.00 28.27 145,370 5,140 Average 5,250 2 4 01/30/2008 56 6.00 28.27 156,520 5,540 Contractor: Duke Construction, LP Concrete Supplier: Potter Concrete Plant: 10 Specification Requirements Strength: 4,000 psi @ 28 days Slump (in.): 4" - 6" Air (%): 3% - 5% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 ~~ ~Q] [)IE lSJ DO D Type 1 Type 2 Type 3 Type 4 Type 5 PROJECT DATA Mix Design 1.0.: 7753PW Placement Date: 12/05/2007 Weather Conditions: Clear Time Sampled: 04:30am Temperature - Air: 440F Truck No: 136 Air Content: 4.4% Overall Placement Location: Paving, Point West VII Batch time: 04:12am Concrete: 800F Ticket No: 9777 Unit Weight (pet): NA Measured Slump (inches) 5.25 Sample Location: 15' north, 750' east from northwest building corner Fracture Type Type2 Type2 Type2 Type6 Type 6 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition. appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (KW/KW) Page 2 of 8 Rone Engineering . Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, 8te 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 307302 Project No.: 0712932 Date of Service: 12/05/2007 Report Date: 02/01/2008 Project: Hemisphere's at Point West Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Set No. Tested (days) (in) (in') (Ibs) (psi) 3 1 12/12/2007 7 6.00 28.27 105,950 3,750 3 2 01/02/2008 28 6.00 28.27 144,900 5,120 3 3 01/02/2008 28 6.00 28.27 139,800 4,940 Average 5,030 3 4 01/30/2008 56 6.00 28.27 148,600 5,260 Contractor: Duke Construction, LP Concrete Supplier: Potter Concrete Plant: 10 Specification Requirements Strength: 4,000 psi @ 28 days Slump (in.): 4" - 6" Air (%): 3% - 5% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 0[3 ~Q] 5IE L] DO D Type 1 Type 2 Type 3 Type 4 Type 5 PROJECT DATA Mix Design 1.0.: 7753PW Placement Date: 12/05/2007 Weather Conditions: Clear Time Sampled: 06:05am Temperature - Air: 500F Truck No: 144 Air Content: 4.3% Overall Placement Location: Paving, Point West VII Batch time: 05:50am Concrete: 820F Ticket No: 9792 Unit Weight (pet): NA Measured Slump (inches) 5.75 Sample Location: 75' north, 825' east from northwest building corner Fracture Type Type2 Type2 Type2 Type2 Type 6 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (KW/KW) Page 3 of 8 Rone Engineering . Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 307302 Project No.: 0712932 Date of Service: 12/05/2007 Report Date: 02/01/2008 Project: Hemisphere's at Point West Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Set No. Tested (days) (in) (in2) (Ibs) (psi) 4 1 12/12/2007 7 6.00 28.27 104,130 3,680 4 2 01/02/2008 28 6.00 28.27 146,460 5,180 4 3 01/02/2008 28 6.00 28.27 147,700 5,220 Average 5,200 4 4 01/30/2008 56 6.00 28.27 152,790 5,400 Contractor: Duke Construction, LP Concrete Sl'"'lplier: Potter Concrete Plant: 10 Specification Requirements Strength: 4,000 psi @ 28 days Slump (in.): 4" - 6" Air (%): 3% - 5% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 ~23 ~[g 5lE E;J DO D Type 1 Type 2 Type 3 Type 4 Type 5 PROJECT DATA Mix Design 1.0.: 7753PW Placement Date: 12/05/2007 Weather Conditions: Sunny, clear Time Sampled: 07:15am Batch time: 07:00am Temperature - Air: 530F Concrete: 840F Truck No: 120 Ticket No: 9807 Air Content: 4.5% Unit Weight (pet): NA Overall Placement Location: Paving, Point West VII Measured Slump (inches) 5.75 Sample Location: 10' north, 900' east from northwest building corner Fracture Type Type3 Type5 Type6 Type2 Type 6 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (KW/KW) Page 4 of 8 Rone Engineering . Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 307302 Project No.: 0712932 Date of Service: 12/05/2007 Report Date: 02/01/2008 Project: Hemisphere's at Point West Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. Contractor: Duke Construction, LP Concrete Supplier: Potter CC'lcrete Plant: 10 Specification Requirements Strength: 4,000 psi @ 28 days Slump (in.): 4" - 6" Air (%): 3% - 5% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 PROJECT DATA Mix Design I.D.: 7753PW Placement Date: 12/05/2007 Weather Conditions: Sunny, clear Time Sampled: 09:30am Batch time: 09: 13am Temperature - Air: 600F Concrete: 860F Truck No: 117 Ticket No: 9824 Air Content: 4.4% Unit Weight (pet): NA Overall Placement Location: Paving, Point West VII Measured Slump (inches) 5.0 Sample Location: 25' south, 600' east from southwest building corner REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Fracture Set No. Tested (days) (in) (inZ) (Ibs) (psi) Type 5 1 12/12/2007 7 6.00 28.27 125,820 4,450 Type2 5 2 01/02/2008 28 6.00 28.27 164,470 5,820 Type2 5 3 01/02/2008 28 6.00 28.27 165,930 5,870 Type2 Average 5,840 5 4 01/30/2008 56 6.00 28.27 168,920 5,970 Type6 l8)~ ~Q] ~ l5] DO D Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (KW/KW) Page 5 of 8 Rone Engineering . Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 307302 Project No.: 0712932 Date of Service: 12/05/2007 Report Date: 02/01/2008 Project: Hemisphere's at Point West Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Set No. Tested (days) (in) (in2) (Ibs) (psi) 6 1 12/12/2007 7 6.00 28.27 126,230 4,460 6 2 01/02/2008 28 6.00 28.27 166,400 5,890 6 3 01/02/2008 28 6.00 28.27 165,990 5,870 Average 5,880 6 4 01/30/2008 56 6.00 28.27 168,210 5,950 Contractor: Duke Construction, LP Concrete Supplier: Potter Concrete Plant: 10 Specification Requirements Strength: 4,000 psi @ 28 days Slump (in.): 4" - 6" Air (%): 3% - 5% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 ~~ ~~ Krn EJ DO D Type 1 Type 2 Type 3 Type 4 Type 5 PROJECT DATA Mix Design I.D.: 7753PW Placement '1ate: 12/05/2007 Weather Conditions: Clear Time Sampled: 11 AOam Temperature - Air: 600F Truck No: 134 Air Content: 4.5% Overall Placement Location: Paving, Point West VII Batch time: 11 :22am Concrete: 860F Ticket No: 9838 Unit Weight (pet): NA Measured Slump (inches) 5.0 Sample Location: 20' south, 500' east from southwest building corner Fracture Type Type2 Type2 Type2 Type2 Type 6 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance. etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, ltd. (KW/KW) Page 7 of 8 Rone Engineering . Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 8908 Ambassador Row, Dallas, TX 75247 7701 W LitUe York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 307460 Project No.: 0712932 Date of Service: 12/06/2007 Report Date: 02/01/2008 Project: Hemisphere's at Point West Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. Contractor: Duke Construction, LP Concrete Supplier: Potter Concrete Plant: 1 Specification Requirements Strength: 4,000 psi @ 28 days Slump (in.): 4" - 6" Air (%): 3% - 5% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 P~OJECT DATA Mix Design I.D.: 7753PW Placement Date: 12/06/2007 Weather Conditions: Clear Time Sampled: 07:10am Temperature - Air: 500F Truck No: 103 Air Content: 4.6% Overall Placement Location: Paving Batch time: 06:46am Concrete: 800F Ticket No: 17395 Unit Weight (pet): NA Measured Slump (inches) 5.25 Sample Location: 50' south, 700' east from southwest building corner REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Fracture Set No. Tested (days) (in) (in') (Ibs) (psi) Type 1 1 12/13/2007 7 6.00 28.27 124,130 4,390 Type2 2 01/03/2008 28 6.00 28.27 156,380 5,530 Type5 3 01/03/2008 28 6.00 28.27 156,230 5,530 Type2 Average 5,530 4 01/31/2008 56 6.00 28.27 173,360 6,130 Type2 ~tj ~[g 5IE E;J DO D Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (TM/KW) Page 1 of 6 Rone Engineering . Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 307460 Project No.: 0712932 Date of Service: 12/06/2007 Report Date: 02/01/2008 Project: Hemisphere's at Point West Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Set No. Tested (days) (in) (in') (Ibs) (psi) 2 1 12/13/2007 7 6.00 28.27 114,850 4,060 2 2 01/03/2008 28 6.00 28.27 160,370 5,670 2 3 01/03/2008 28 6.00 28.27 150,530 5,320 Average 5,500 2 4 01/31/2008 56 6.00 28.27 175,390 6,200 Contractor: Duke Construction, LP Concrete Supplier: Potter Concrete Plant: 1 Specification Requirements Strength: 4,000 psi @ 28 days Slump (in.): 4" - 6" Air (%): 3% - 5% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 ~~ ~Q] [U E] DO 0 Type 1 Type 2 Type 3 Type 4 Type 5 PROJECT DATA Mix Design 1.0.: 7753PW Placement Date: 12/06/2007 Weather Conditions: Sunny, clear Time Sampled: 08:30am Batch time: 08:16am Temperature - Air: 520F Concrete: 820F Truck No: 126 Ticket No: 17411 Air Content: 4.5% Unit Weight (pet): NA Overall Placement Location: Paving Measured Slump (inches) 5.25 Sample Location: 25' south, 775' east from southwest building corner Fracture Type Type2 Type2 Type2 Type5 Type 6 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (TMIKW) Page 3 of 6 Rone Engineering . Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 307460 Project No.: 0712932 Date of Service: 12/06/2007 Report Date: 02/01/2008 Project: Hemisphere's at Point West Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Set No. Tested (days) (in) (in2) (Ibs) (psi) 3 1 12/13/2007 7 6.00 28.27 110,090 3,890 3 2 01/03/2008 28 6.00 28.27 135,030 4,780 3 3 01/03/2008 28 6.00 28.27 130,640 4,620 Average 4,700 3 4 01/31/2008 56 6.00 28.27 145,910 5,160 Contractor: Duke Construction, LP Concrete Supplier: Potter Concrete Plant: 1 Specification Requirements Strength: 4,000 psi @ 28 days Slump (in.): 4" - 6" Air (%): 3% - 5% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 GtJ ~~ [)IE E;] DO D Type 1 Type 2 Type 3 Type 4 Type 5 PROJECT DATA Mix Design I.D.: 7753PW Placement Date: 12/06/2007 Weather Conditions: Sunny, clear Time Sampled: 08:30am Batch time: 08:16am Temperature - Air: 520F Concrete: 820F Truck No: 126 Ticket No: 17411 Air Content: 4.5% Unit Weight (pct): NA Overall Placement Location: Paving Measured Slump (inches) 5.25 Sample Location: 25' south, 775' east from southwest building corner Fracture Type Type5 Type4 Type6 Type2 Type 6 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (TM/KW) Page 5 of 6