Duke Lesley 2A-LR080130 Rone Engineering . Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 307153 Project No.: 0712932 Date of Service: 12/04/2007 Report Date: 01/30/2008 Project: Hemisphere's at Point West Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Set No. Tested (days) (in) (in') (Ibs) (psi) 1 1 12/11/2007 7 6.00 28.27 96,700 3,420 1 2 01/01/2008 28 6.00 28.27 150,250 5,310 1 3 01/01/2008 28 6.00 28.27 143,460 5,070 Average 5,190 4 01/29/2008 56 6.00 28.27 151,070 5,340 Contractor: Duke Construction, LP Concrete Supplier: PC''ter Concrete Plant: 1 0 Specification Requirements Strength: 4,000 psi @ 28 days Slump (in.): 4" - 6" Air (%): 3% - 5% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 ~EJ ~~ Krn ~ DO D Type 1 Type 2 Type 3 Type 4 Type 5 PROJECT DATA Mix Design I.D.: 7753PW Placement Date: 12/04/2007 Weather Conditions: Clear Time Sampled: 03:00am Temperature - Air: 400F Truck No: 108 Air Content: 4.1 % Overall Placement Location: Paving Batch time: 02:45am Concrete: 800F Ticket No: 9655 Unit Weight (pet): NA Measured Slump (inches) 5.0 Sample Location: 150' north, 10' east from northwest building corner Fracture Type Type5 Type5 Type5 Type5 Type 6 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition. appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (TM/KW) Page 1 of 16 Rone Engineering . Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 307153 Project No.: 0712932 Date of Service: 12/04/2007 Report Date: 01/30/2008 Project: Hemisphere's at Point West Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing. cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. Contractor: Duke Construction, LP Concrete Supplier: Potter Concrete Plant: 10 Specification Requirements Strength: 4,000 psi @ 28 days Slump (in.): 4" - 6" Air (%): 3% - 5% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 PROJECT DATA Mix Design I.D.: 7753PW Plac'- ment Date: 12/04/2007 Weather Conditions: Clear Time Sampled: 04:45am Temperature - Air: 400F Truck No: 138 Air Content: 4.2% Overall Placement Location: Paving Batch time: 04:23am Concrete: 800F Ticket No: 9670 Unit Weight (pct): NA Measured Slump (inches) 5.0 Sample Location: 100' north, 100' east from northwest building corner REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Fracture Set No. Tested (days) (in) (in') (Ibs) (psi) Type 2 1 12/11/2007 7 6.00 28.27 100,850 3,570 Type2 2 2 01/01/2008 28 6.00 28.27 151,130 5,350 Type6 2 3 01/01/2008 28 6.00 28.27 143,080 5,060 Type2 Average 5,200 2 4 01/29/2008 56 6.00 28.27 163,330 5,780 Type2 ~EJ [9J[g ~ E;J DO D Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 LIMITATIONS The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition. appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services. Ltd. (TM/KW) Page 3 of 16 Rone Engineering . Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 307153 Project No.: 0712932 Date of Service: 12/04/2007 Report Date: 01/30/2008 Project: Hemisphere's at Point West Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. Contractor: Duke Construction, LP Concrete Supplier: Potter Concrete Plant: 10 Specification Requirements Strength: 4,000 psi @ 28 days Slump (in.): 4" - 6" Air (%): 3% - 5% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 PROJECT DATA Mix Design I.D.: 7753PW Placement Date: 12/04/2007 Weather Conditions: Clear Time Sampled: 05:50am Temperature - Air: 420F Truck No: 139 Air Content: 4.0% Overall Placement Location: Paving Batch time: 05:33am Concrete: 800F Ticket No: 9685 Unit Weight (pct): NA Measured Slump (inches) 5.75 Sample Location: 125' north, 215' east from northwest building corner REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Fracture Set No. Tested (days) (in) (in') (Ibs) (psi) Type 3 1 12/11/2007 7 6.00 28.27 86,630 3,060 Type2 3 2 01/01/2008 28 6.00 28.27 125,890 4,450 Type6 3 3 01/01/2008 28 6.00 28.27 123,370 4,360 Type6 Average 4,410 3 4 01/29/2008 56 6.00 28.27 127,750 4,520 Type3 ~EJ ~[g [)IE ~ DO D Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (TM/KW) Page 5 of 16 Rone En~=:; Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 307153 Project No.: 0712932 Date of Service: 12/04/2007 Report Date: 01/30/2008 Project: Hemisphere's at Point West Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Set No. Tested (days) (in) (in2) (Ibs) (psi) 4 1 12/11/2007 7 6.00 28.27 90,290 3,190 4 2 01/01/2008 28 6.00 28.27 125,660 4,440 4 3 01/01/2008 28 6.00 28.27 123,920 4,380 Average 4,410 4 4 01/29/2008 56 6.00 28.27 132,770 4,700 Contractor: Duke Construction, LP Concrete Supplier: Potter Concrete Plant: 10 Specification Requirements Strength: 4,000 psi @ 28 days Slump (in.): 4" - 6" Air (%): 3% - 5% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 ~E3 ~.. ~ ~ DO D Type 1 Type 2 Type 3 Type 4 Type 5 PROJECT DATA Mix Design I.D.: 7753PW Placement Date: 12/04/2007 Weather Conditions: Clear Time Sampled: 07:00am Temperature - Air: 450F Truck No: 110 Air Content: 4.3% Overall Placement Location: Paving Batch time: 06:42am Concrete: 800F Ticket No: 9699 Unit Weight (pet): NA Measured Slump (inches) 5.75 Sample Location: 25' north, 300' east from northwest building corner Fracture Type Type6 Type2 Type2 Type2 Type 6 LIMITATIONS: The test results presented herein were prepared based upon the speCific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (TM/KW) Page 7 of 16 Rone Engineering . Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 307153 Project No.: 0712932 Date of Service: 12/04/2007 Report Date: 01/30/2008 Project: Hemisphere's at Point West Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. Contractor: Duke Construction, LP Concrete Supplier: Potter Concrete Plant: 10 Specification Requirements Strength: 4,000 psi @ 28 days Slump (in.): 4" - 6" Air (%): 3% - 5% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 PROJECT DATA Mix Design I.D.: 7753PW Placement Date: 12/04/2007 Weather Conditions: Sunny, clear Time Sampled: 08:55am Batch time: 08:36am Temperature - Air: 520F Concrete: 820F Truck No: 103 Ticket No: 9716 Air Content: 4.5% Unit Weight (pct): NA Overall Placement Location: Paving Measured Slump (inches) 5.25 Sample Location: 75' north, 375' east from northwest building corner REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Fracture Set No. Tested (days) (in) (in') (Ibs) (psi) Type 5 1 12/11/2007 7 6.00 28.27 102,430 3,620 Type2 5 2 01/01/2008 28 6.00 28.27 145,330 5,140 Type5 5 3 01/01/2008 28 6.00 28.27 137,030 4,850 Type5 Average 4,990 5 4 01/29/2008 56 6.00 28.27 152,680 5,400 Type2 ~~ [Sj[g rnJ EJ DO D Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (fM/KW) Page 9 of 16 Rone Engineering . Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 307153 Project No.: 0712932 Date of Service: 12/04/2007 Report Date: 01/30/2008 Project: Hemisphere's at Point West Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Set No. Tested (days) (in) (in') (Ibs) (psi) 6 1 12/11/2007 7 6.00 28.27 105,910 3,750 6 2 01/01/2008 28 6.00 28.27 150,020 5,310 6 3 01/01/2008 28 6.00 28.27 146,620 5,190 Average 5,250 6 4 01/29/2008 56 6.00 28.27 156,760 5,540 Contractor: Duke Construction, LP Concrete Supplier: Potter Concrete Plant: 10 Specification Requirements Strength: 4,000 psi @ 28 days Slump (in.): 4" - 6" Air (%): 3% - 5% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1 064 ASTM C-138 ASTM C-39 ~tj ~[&J fIE bJ DO D Type 1 Type 2 Type 3 Type 4 Type 5 PROJECT DATA Mix Design I.D.: 7753PW Placement Date: 12/04/2007 Weather Conditions: Sunny, clear Time Sampled: 09:55am Batch time: 09:39am Temperature - Air: 550F Concrete: 840F Truck No: 139 Ticket No: 9730 Air Content: 4.4% Unit Weight (pcf): NA Overall Placement Location: Paving Measured Slump (inches) 5.0 Sample Location: 50' north, 450' east from northwest building corner Fracture Type Type6 Type5 Type3 Type2 Type 6 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition. appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (TM/KW) Page 11 of 16 Rone Engineering . Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 307153 Project No.: 0712932 Date of Service: 12/04/2007 Report Date: 01/30/2008 Project: Hemisphere's at Point West Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Set No. Tested (days) (in) (in') (Ibs) (psi) 7 1 12/11/2007 7 6.00 28.27 116,930 4,140 7 2 01/01/2008 28 6.00 28.27 148,250 5,240 7 3 01/01/2008 28 6.00 28.27 139,430 4,930 Average 5,090 7 4 01/29/2008 56 6.00 28.27 157,710 5,580 Contractor: Duke Construction, LP Concrete Supplier: Potter ConC'"ete Plant: 10 Specification Requirements Strength: 4,000 psi @ 28 days Slump (in.): 4" - 6" Air (%): 3% - 5% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 l8JE] ~Q] ~ ~ DO D Type 1 Type 2 Type 3 Type 4 Type 5 PROJECT DATA Mix Design I.D.: 7753PW Placement Date: 12/04/2007 Weather Conditions: Sunny, clear Time Sampled: 11 :10am Batch time: 10:48am Temperature - Air: 580F Concrete: 880F Truck No: 138 Ticket No: 9744 Air Content: 4.5% Unit Weight (pct): NA Overall Placement Location: Paving Measured Slump (inches) 4.75 Sample Location: 100' north, 550' east from northwest building corner Fracture Type Type6 Type2 Type5 Type2 Type 6 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (TM/KW) Page 13 of 16 Rone Engineering . Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 307153 Project No.: 0712932 Date of Service: 12/04/2007 Report Date: 01/30/2008 Project: Hemisphere's at Point West Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Set No. Tested (days) (in) (in') (Ibs) (psi) 8 1 12/11/2007 7 6.00 28.27 112,710 3,990 8 2 01/01/2008 28 6.00 28.27 141,920 5,020 8 3 01/01/2008 28 6.00 28.27 137,940 4,880 Average 4,950 8 4 01/29/2008 56 6.00 28.27 159,250 5,630 Contractor: Duke Construction, LP Concrete Supplier: Potter Concrete Plant: 10 Specification Requirements Strength: 4,000 psi @ 28 days Slump (in.): 4" - 6" Air (%): 3% - 5% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 ~~ ~~ ~ LJ DO D Type 1 Type 2 Type 3 Type 4 Type 5 PROJECT DATA Mix Design 1.0.: 7753PW Placement D;>~e: 12/04/2007 Weather Conditions: Sunny, clear Time Sampled: 12:20pm Batch time: 12:06pm Temperature - Air: 600F Concrete: 860F Truck No: 138 Ticket No: 9760 Air Content: 4.2% Unit Weight (pct): NA Overall Placement Location: Paving Measured Slump (inches) 4.75 Sample Location: 125' north, 675' east from northwest building corner Fracture Type Type6 Type3 Type6 Type2 Type 6 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (TM/KW) Page 15 of 16