Duke Lesley 1A-LR080201
Rone Engineering
.
8908 Ambassador Row, Dallas, TX 75247
7701 W Little York, Ste 600, Houston, TX 77040
4421 Freidrich, Ste 195, Austin, TX 78744
Corporate Phone: (214) 630-9745
Client:
Duke Construction, LP
14241 Dallas Pkwy, Ste 1000
Dallas, TX 75254-2936
Report of Reinforcing Steel Inspection
Report No.: 311849
Project No.: 0713408
Date of Service: 01/28/2008
Report Date: 02/01/2008
Project: Point West VII (A
Coppell, Texas
Services: Reinforcing Steel Inspection
Report of Inspection
Locatir>ns and Items Inspected:
Paving on southwest to northwest corner of building. Also paving
on northwest approach and fire lane.
Items Inspected: Conforming Non Item s Inspected: Conforming Non Item sins pected: Co nfo rm jng Non
Conforming Conforming Co nfo rm ing
P lacing Drawings Bar Length Column Ties Properly
Approved x and Shape x Tied and Spaced N/A
BarSize x Pro per Bar P lacem ent x Stirrup Spacing N/A
Bar Grade x Pro perly Tied x Stirrup Type N/A
Bars Clean Note 1 Dowel Bars in Place x Lapped Splices x
Form Clean Nole 2 Pro per B ar Suppo rts Note 3 CornerSars N/A
Numberof Bars x P roper Cover x Mechanical Splices N/A
Discrepancies / Comments: Note 1: Remove mud/soil from steel at various locations
Note 2: Remove trash from placement area
Note 3: Missing chairs
The discrepancies noted above were corrected at the time of inspection.
Technician: Jose Villanueva Started: 03:30pm
Report Distribution:
Orig: Duke Construction, LP (Dallas, TX)
Attn: Mr. Emmit Coots (1-ec copy)
1-cc Duke Construction, LP Attn: Mr. Emmit Coots
1-cc City of Coppell Attn: Mr. Lee Stone
1-cc City of Coppell Attn: Mr. Larry Davis
1-cc Pacheco Koch Consulting Engineers Attn: Mr. Jack Evans
Finished: 05:30pm Rone Engineering
p~~
K. Scott Watson, AET
Project Manager
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd.
(CH/KW) Page 1 of 1
Rone Eni~
8908 Ambassador Row, Dallas, TX 75247
7701 W Little York, Ste 600, Houston, TX 77040
4421 Freidrich, Ste 195, Austin, TX 78744
Corporate Phone: (214) 630-9745
Client:
Duke Construction, LP
14241 Dallas Pkwy, Ste 1000
Dallas, TX 75254-2936
Report of Reinforcing Steel Inspection
Report No.: 311787
Project No.: 0713408
Date of Service: 01/28/2008
Report Date: 02/01/2008
Project: Point West VI
Coppell, Texas
Services: Reinforcing Steel Inspection
Report of Inspection
Locations and Items Inspected:
(Paving) Loading dock on south side of building
Ilems Inspected: Conforming Non Ilems Inspected: Co nfo rm ing Non Item s Ins peeled: Co nfo rm jng Non
Conforming Conforming Conforming
P lac ing 0 rawings Bar Length ColumnTies Properly
Approved x and Shape x Tied and Spaced N/A
Bar Size x Proper B ar Placement x Stirrup Spacing N/A
Bar Grade x Pro perly Tied x Stirrup Type N/A
Bars Clean x Dowel Bars in Place x Lapped Splices N/A
Form Clean x Pro per Bar Suppo rts x CornerBars N/A
N urn ber of Bars x ProperCover x Mechanical Splices N/A
Discrepancies / Comments:
No discrepancies at the location noted above.
Technician: Javier Martinez Started: 02:15am
Report Distribution:
Orig: Duke Construction, LP (Dallas, TX)
Attn: Mr. Emmit Coots (1-ec copy)
1-cc Duke Construction. LP Attn: Mr. Emmit Coots
1-cc City of Coppell Attn: Mr. Lee Stone
1-cc City of Coppell Attn: Mr. Larry Davis
1-cc Pacheco Koch Consulting Engineers Attn: Mr. Jack Evans
Finished: 03:00am
Rone Engineering
p~~
K. Scott Watson, AET
Project Manager
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd.
(CHIKW) Page 1 of 1