Duke Lesley 1A-LR080022
Rone Engineering
.
8908 Ambassador Row, Dallas, TX 75247
7701 W Little York, Ste 600, Houston, TX 77040
4421 Freidrich, Ste 195, Austin, TX 78744
Corporate Phone: (214) 630-9745
Project: Point West VI
Coppell, Texas
Services: Reinforcing Steel Inspection
~
Report of Reinforcing Steel Inspection
Report No.: 311207
Project No.: 0713408
Date of Service: 01/18/2008
Report Date: 01/22/2008
Client:
Duke Construction, LP
14241 Dallas Pkwy, Ste 1000
Dallas, TX 75254-2936
Report of Inspection
Locations ald Items Inspected:
Paving on side of building, pour 4, inner pour, south and north
side of building.
Nem s Inspected: Conforming Non Items Inspected: Conforming Non Item sins pected: Conforming Non
Co nfo rming Conforming Conforming
Placing Drawings Bar Length Co lumn Ties Pro periy
Approved x and Shape x Tied and Spaced NA
Bar Size x Proper B ar Placement x Stirrup Spacing NA
Bar Grade x Pro perly Tied x Stirrup Type NA
Bars Clean x Dowel Bars in Place x Lapped Splices x
Form Clean x Proper B ar Suppa rts x Corner Bars NA
NumberofBars x ProperCover x Mechanical Splices NA
Discrepancies I Comments: 1. Remove excess dry concrete from placement area.
2. Tie down steel.
3. Missing dowels.
4. Add chairs.
The discrepancies noted above were corrected at the time of inspection.
fi(~
~/~ I': 8
Technician: Jose Villanueva Started: 02:00pm
Report Distribution:
Orig: Duke Construction, LP (Dallas, TX)
Alln: Mr. Emmit Coots (1-ec copy)
1-cc Duke Construction, LP Alln: Mr. Emmit Coots
1-cc City of Coppell Alln: Mr. Lee Stone
1-cc City of Coppell Alln: Mr. Larry Davis
1-cc Pacheco Koch Consulting Engineers Alln: Mr. Jack Evans
Finished: 04:45pm Rone Engineering
P-~~
K. Scott Watson, AET
Project Manager
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd.
(TM/KW) Page 1 of 1