Loading...
Northlake College-LR080211 KlEINFElDER 2211 Century Center Blvd., Suite 101, Irving, Texas 75062 972-870-0808 Metro 972-953-0398 Fax 972-870-0802 4x8 CONCRETE CYLINDER COMPRESSIVE STRENGTH REPORT TO: Dallas County Community College Dist. 1505 South Lamar, Suite 1015 Dallas, Texas 75215 PROJECT: North Lake College, N Campus W Sandy Lake Road @ SH 121 PROJECT NO: 87015 TECHNICIAN: J. Mayo REPORT DATE: 2/11/2008 REPORT NO: 018098 CONCRETE FOR: Pavement left turn lane on Royal Ln., 80' E from SE entrance ramp CYLINDER AGE DATE DATE AVG. CYLINDER CYLINDER FRACTURE TOTAL COMPRESSIVE MARK DAYS CAST TESTED DIAMETER, IN. AREA, IN.2 TYPE LOAD, LBS STRENGTH, PSI 018098A 7 1/11/08 1/18/08 3.99 12.50 3 58,220 4,660 018098B 28 1/11/08 2/8/08 4.00 12.57 3 77,390 6,160 018098C 28 1/11/08 2/8/08 4.00 12.57 3 77,580 6,170 0180980 HOLD 1/11/08 HOLD SUPPLIER: Southern Star MIX DESIGN: 000000007725 ADDITIONAL INFORMATION IF MADE BY KLEINFELDER: AVERAGE 28 DAY STRENGTH: 6,165 28 DAY STRENGTH REQUIREMENT: 4,000 TRUCK NO. : TICKET NO. : ACCUMULATED YDS : TIME CAST: TIME IN TRUCK: WEATHER: 1011 1177333 1 0 of 40 10:02 AM 42 min Clear SLUMP: AIR TEMP. : MIX TEMP. : AIR CONTENT: WATER ADDED (gal) : UNIT WEIGHT: SPECIFIED FRACTURE TYPES: 1 Reasonably well-formed cones on both ends, less than 1 in. (25 mm) of cracking through caps. 2 Well-formed cone on one end, vertical cracks running through caps, no well-defined cone on other end. 3 Columnar vertical cracking through both ends, no well-formed cones. 4 Diagonal fracture with no cracking through ends: tap with hammer to distinguish from Type 1. 5 Side fractures at top or bottom (occur commonly with unbonded caps). r f i NOTES. Compressive strengths determined in accordance with ASTM C39. . Cross-sectional area, diameter and length are standard unless otherwise noted. . Portions of the information contained in this report have been furnished by others. . Cylinders cured in laboratory in accordance with ASTM C31 unless otherwise noted. . Unbonded caps utilized in accordance with ASTM C 1231 unless otherwise noted. Because of the violent release of energy stored in pads, the broken cylinder rarely exhibits conical fracture typical of capped cylinders and the sketches of types of fracture in Test Method C39 are not descriptive . Samples taken in accordance with ASTM C172 where practicable' When applicable, the following test procedures were used: Slump ASTM C143; Unit Weight ASTM C138; Air Content ASTM C173/ C231; Temperature ASTM C1064 Reports to: Starling Richardson Const.; Attn: Eric Stanaland (eps@starlingrichard Starling Richardson Const.; Attn: Andy Munoz (amunoz@starlingric r DCCCD Bond Office; Attn: Brenda Spinelli (brenda.spinelli@dcccd DCCCD Bond Office; Attn: James Williams (james.williams@dcc DCCCD Bond Office; Attn: Mike Daniels (mike.daniels@dcccd.ed ) Jacobs; Attn: Andrea Stogner (Andrea.stogner@jacobs.com) \ Jacobs, Attn Jennifer Blount (Jennifer blount@jacobs.com) t I A 1- City of Coppell, Attn Larry Davis I V ~ 1- City of Coppell, Attn Lee Stone The results shown on this report are for the exclUSive use of the chent for whom they were obtained and ap y only to the samples tested and/or Inspected They are not intended to be indicative of the qualities of apparently identical products The use of our name must receive prior written approval Reports must be reproduced in their entirety. /. ZjJ~