Duke Lesley 1A-LR080207 Rone Engineering . Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 312071 Project No.: 0713408 Date of Service: 01/30/2008 Report Date: 02/07/2008 Project: Point West VI Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA Contractor: Duke Construction, LP Concrete Supplier: Potter Concrete Plant: On site Specification Requirements Strength: 4,000 psi @ 28 days Slump (in.): 4" - 6" Air (%): 4% - 6% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 Batch time: 02:57am Concrete: 510F Ticket No: 18904 Unit Weight (pet): NA Measured Slump (inches) 5.75 Mix Design I.D.: 7753 Placement Date: 01/30/2008 Weather Conditions: Clear Time Sampled: 03:30am Temperature - Air: 320F Truck No: 133 Air Content: 6.0% Overall Placement Location: (Paving) loading dock parking south side of building, parking spaces and driveway on northwest corner of building Sample Location: 60' west, 60' north from grid line A.1 REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Fracture Set No. Tested (days) (in) (in2) (Ibs) (psi) Type 1 1 02/06/2008 7 6.01 28.37 92,950 3,280 Type2 1 2 02/27/2008 28 1 3 02/27/2008 28 1 4 03/26/2008 56 [8JE3 ~[g 5ill ~ DO D Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance. etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (CH/KW) Page 1 of 11 Rone Engineering . Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 312071 Project No.: 0713408 Date ot Service: 01/30/2008 Report Date: 02/07/2008 Project: Point West VI Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA Contractor: Duke Construction, LP Concrete ~upplier: Potter Concrete Plant: On site Specification Requirements Strength: 4,000 psi @ 28 days Slump (in.): 4" - 6" Air (%): 4% - 6% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 Batch time: 04: 11 am Concrete: 520F Ticket No: 18915 Unit Weight (pet): NA Measured Slump (inches) 5.75 Mix Design 1.0.: 7753 Placrment Date: 01/30/2008 Weather Conditions: Clear Time Sampled: 04:35am Temperature - Air: 310F Truck No: 133 Air Content: 5.7% Overall Placement Location: (Paving) loading dock parking south side of building, parking spaces and driveway on northwest corner of building Concrete Compressive Cylinder 6" x 12" Maximum Load (Ibs) 96,320 Area (in') 28.27 Type 6 Sample Location: 50' north from grid line A.1 REPORT OF TESTS Compressive Strength (psi) 3,410 Fracture Type Type3 Cylinder Marked Date Set No. Tested 2 1 02/06/2008 2 2 02/27/2008 2 3 02/27/2008 2 4 03/26/2008 Age (days) 7 Diameter (in) 6.00 28 28 56 ~EJ ~~ fllj ~ DO D Type 1 Type 2 Type 3 Type 4 Type 5 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (CH/KW) Page 2 of 11 Rone Engineering . Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 312071 Project No.: 0713408 Date of Service: 01/30/2008 Report Date: 02/07/2008 Project: Point West VI Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA Contractor: Duke Construction, LP Concrete Supplier: Potter C-mcrete Plant: On site Specification Requirements Strength: 4,000 psi @ 28 days Slump (in.): 4" - 6" Air (%): 4% - 6% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 Batch time: Concrete: 500F Ticket No: 18928 Unit Weight (pet): NA Measured Slump (inches) 6.0 Mix Design 1.0.: 7753 Placement Date: 01/30/2008 Weather Conditions: Clear Time Sampled: 05:47am Temperature - Air: 320F Truck No: 126 Air Content: 6.0% Overall Placement Location: (Paving) loading dock parking south side of building, parking spaces and driveway on northwest corner of building Sample Location: 30' north from grid line A.2 REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Fracture Set No. Tested (days) (in) (in2) (Ibs) (psi) Type 3 1 02/06/2008 7 6.00 28.27 95,100 3,360 Type2 3 2 02/27/2008 28 3 3 02/27/2008 28 3 4 03/26/2008 56 ~[j ~Q] [ill] ~ DO D Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services. Ltd. (CH/KW) Page 3 of 11 Rone Engineering . Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 312071 Project No.: 0713408 Date ot Service: 01/30/2008 Report Date: 02/07/2008 Project: Point West VI Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT nATA Contractor: Duke Construction, LP Concrete Supplier: Potter Concrete Plant: On site Specification Requirements Strength: 4,000 psi @ 28 days Slump (in.): 4" - 6" Air (%): 4% - 6% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1 064 ASTM C-138 ASTM C-39 Measured Slump (inches) 5.5 Mix Design I.D.: 7753 Placeme"~ Date: 01/30/2008 Weather Conditions: Clear, windy Time Sampled: 08:31am Batch time: 08:00am Temperature - Air: 370F Concrete: 500F Truck No: 126 Ticket No: 18941 Air Content: 6.0% Unit Weight (pet): NA Overall Placement Location: (Paving) loading dock parking south side of building, parking spaces and driveway on northwest corner of building Sample Location: 75' south from grid line U25.9 REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Fracture Set No. Tested (days) (in) (in2) (Ibs) (psi) Type 4 1 02/06/2008 7 6.00 28.27 114,470 4,050 TypeS 4 2 02/27/2008 28 4 3 02/27/2008 28 4 4 03/26/2008 56 ~~ rrmm ~t:j Type 2 ~ b] DO D Type 1 Type 3 Type 4 Type 5 Type 6 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (CHIKW) Page 5 of 11 Rone Engineering . Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 312071 Project No.: 0713408 Date of Service: 01/30/2008 Report Date: 02/07/2008 Project: Point West VI Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA Contractor: Duke Construction, LP Concrete Supplier: Potter Concrete Plant: On site Specification Requirements Strength: 4,000 psi @ 28 days Slump (in.): 4" - 6" Air (%): 4% - 6% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 Measured Slump (inches) 5.25 Mix Design I.D.: 7753 Placement Date: 01/30/2008 Weather Conditions: Sunny, windy Time Sampled: 09:55am Batch time: Temperature - Air: 390F Concrete: 580F Truck No: 126 Ticket No: 18958 Air Content: 4.7% Unit Weight (pet): NA Overall Placement Location: (Paving) loading dock parking south side of building, parking spaces and driveway on northwest corner of building Sample Location: 35' south from grid line U24.3 REPORT OF TESTS Cylinder Marked Date Set No. Tested 5 1 02/06/2008 5 2 02/27/2008 5 3 02/27/2008 5 4 03/26/2008 Age (days) 7 Diameter (in) 6.00 28 28 56 ~E3 [1]0 [] lSJ DO D Type 1 Type 2 Type 3 Type 4 Type 5 Concrete Compressive Cylinder 6" x 12" Maximum Load (Ibs) 137,840 Compressive Strength (psi) 4,880 Fracture Type Type6 Area (in2) 28.27 Type 6 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (CH/KW) Page 7 of 11 Rone Engineering . Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 312071 Project No.: 0713408 Date of Service: 01/30/2008 Report Date: 02/07/2008 Project: Point West VI Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA Contractor: Duke Construction, LP Concrete Supplier: Potter Concrete Plant: On site Specification Requirements Strength: 4,000 psi @ 28 days Slump (in.): 4" - 6" Air (%): 4% - 6% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 Measured SI'lmp (in~hes) 5.75 Mix Design I.D.: 7753 Placement Date: 01/30/2008 Weather Conditions: Sunny, windy Time Sampled: 11 :OOam Batch time: Temperature - Air: 380F Concrete: 600F Truck No: 139 Ticket No: 18968 Air Content: 5.8% Unit Weight (pct): NA Overall Placement Location: (Paving) loading dock parking south side of building, parking spaces and driveway on northwest corner of building Sample Location: 10' south from grid line U22.9 REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Fracture Set No. Tested (days) (in) (in') (Ibs) (psi) Type 6 1 02/06/2008 7 6.00 28.27 92,970 3,290 Type6 6 2 02/27/2008 28 6 3 02/27/2008 28 6 4 03/26/2008 56 ~~ ~Q] Krn Q DO D Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the ciients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (CHfKW) Page 8 of 11 Rone Engineering . Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 312071 Project No.: 0713408 Date of Service: 01/30/2008 Report Date: 02/07/2008 Project: Point West VI Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA Contractor: Duke Construction, LP Concrete Supplier: Potter Concrete Plant: On site Specification Requirements Strength: 4,000 psi @ 28 days Slump (in.): 4" - 6" Air (%): 4% - 6% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 Measured Slump (inches) 5.75 Mix Design 1.0.: 7753 Placement Date: 01/30/2008 Weather Conditions: Sunny, windy Time Sampled: 12:15pm Batch time: 11:27am Temperature - Air: 460F Concrete: 610F Truck No: 126 Ticket No: 18978 Air Content: 5.2% Unit Weight (pct): NA Overall Placement Location: (Paving) loading dock parking south side of building, parking spaces and driveway on northwest corner of building Sample Location: 40' south from grid line U21. 7 REPORT OF TESTS Cylinder Marked Date Set No. Tested 7 1 02/06/2008 7 2 02/27/2008 7 3 02/27/2008 7 4 03/26/2008 Age (days) 7 Diameter (in) 6.00 28 28 56 ~E3 ~l9 ~ Q DO D Type 1 Type 2 Type 3 Type 4 Type 5 Concrete Compressive Cylinder 6" x 12" Maximum Load (Ibs) 121,680 Compressive Strength (psi) 4,300 Fracture Type TypeS Area (in') 28.27 Type 6 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance. etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (CH/KW) Page 10 of 11