Duke Lesley 1A-LR080205 Rone Engineering . Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 307701 Project No.: 0713408 Date of Service: 12/08/2007 Report Date: 02/05/2008 Project: Point West VI Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Set No. Tested (days) (in) (in') (Ibs) (psi) 1 1 12/15/2007 7 6.00 28.27 109,950 3,890 1 2 01/05/2008 28 6.00 28.27 143,710 5,080 1 3 01/05/2008 28 6.00 28.27 148,670 5,260 Average 5,170 4 02/02/2008 56 6.00 28.27 161,330 5,710 Contractor: Duke Construction, LP Concrete Supplier: Potter Concrete Plant: On site Specification Requirements Strength: 4,000 psi @ 28 days Slump (in.): 4" - 6" Air (%): 3% - 6% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 0~ [S]~ ~ G DO D Type 1 Type 2 Type 3 Type 4 Type 5 Measured Slump (inches) 5.0 Mix Design I.D.: 7753 Placement Date: 12/08/2007 Weather Conditions: Mostly cloudy Time Sampled: 03:45am Batch time: Temperature - Air: 670F Concrete: 730F Truck No: 126 Ticket No: Air Content: 4.0% Unit Weight (pet): NA Overall Placement Location: Paving - 3rd section at north side of building VI - 60' north start, 120' end, grid line A/8.2-A/17.3 Sample Location: Gridline A/17.1 - 90' north Fracture Type Type2 Type2 Type2 Type2 Type 6 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (DMlKW) Page 1 of 11 Rone Engineering . Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 307701 Project No.: 0713408 Date of Service: 12/08/2007 Report Date: 02/05/2008 Project: Point West VI Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Set No. Tested (days) (in) (inZ) (Ibs) (psi) 2 1 12/15/2007 7 6.00 28.27 87,930 3,110 2 2 01/05/2008 28 6.00 28.27 123,040 4,350 2 3 01/05/2008 28 6.00 28.27 126,820 4,490 Average 4,420 2 4 02/02/2008 56 6.00 28.27 147,490 5,220 Contractor: Duke Construction, LP Concrete Supplier: Potter Concrete Plant: On site Specification Requirements Strength: 4,000 psi @ 28 days Slump (in.): 4" - 6" Air (%): 3% - 6% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 ~E3 ~~ fIE G DO D Type 1 Type 2 Type 3 Type 4 Type 5 Measured Slump (inches) 6.0 Mix Design I.D.: 7753 Placement Date: 12/08/2007 Weather Conditions: Mostly cloudy Time Sampled: 04:45am Batch time: Temperature - Air: 690F Concrete: 700F Truck No: 101 Ticket No: Air Content: 5.0% Unit Weight (pcf): NA Overall Placement Location: Paving - 3rd section at north side of building VI - 60' north start, 120' end, grid line A1B.2-A/17.3 Sample Location: Gridline A/16.3 - 77' north Fracture Type Type2 Type2 Type2 Type6 Type 6 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition. appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (DM/KW) Page 3 of 11 Rone Engineering . Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 307701 Project No.: 0713408 Date of Service: 12/08/2007 Report Date: 02/05/2008 Project: Point West VI Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Set No. Tested (days) (in) (in') (Ibs) (psi) 3 1 12/15/2007 7 6.00 28.27 90,250 3,190 3 2 01/05/2008 28 6.00 28.27 131,080 4,640 3 3 01/05/2008 28 6.00 28.27 136,910 4,840 Average 4,740 3 4 02/02/2008 56 6.00 28.27 158,930 5,620 Contractor: Duke Construction, LP Concrete Supplier: Potter Concrete Plant: On site Specification Requirements Strength: 4,000 psi @ 28 days Slump (in.): 4" - 6" Air (%): 3% - 6% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 ~E:j ~Q;J ~ E] DO D Type 1 Type 2 Type 3 Type 4 Type 5 PROJECT DATA Measured Slump (inch JS) 5.75 Mix Design I.D.: 7753 Placement Date: 12/08/2007 Weather Conditions: Mostly cloudy Time Sampled: 05:45am Batch time: Temperature - Air: 660F Concrete: 710F Truck No: 130 Ticket No: Air Content: 4.7% Unit Weight (pet): NA Overall Placement Location: Paving - 3rd section at north side of building VI- 60' north start, 120' end, grid line A/8.2-A/17.3 Sample Location: Gridline A/14. 7 - 115' north Fracture Type Type3 Type2 Type2 Type2 Type 6 LIMIT A nONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (DM/KW) Page 5 of 11 Rone Engineering . Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 307701 Project No.: 0713408 Date of Service: 12/08/2007 Report Date: 02/05/2008 Project: Point West VI Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Set No. Tested (days) (in) (in') (Ibs) (psi) 4 1 12/15/2007 7 6.00 28.27 89,290 3,160 4 2 01/05/2008 28 6.00 28.27 124,970 4,420 4 3 01/05/2008 28 6.00 28.27 124,950 4,420 Average 4,420 4 4 02/0212008 56 6.00 28.27 144,410 5,110 Contractor: Duke Construction, LP Concrete Supplier: Potter Concrete Plant: On site Specification Requirements Strength: 4,000 psi @ 28 days Slump (in.): 4" - 6" Air (%): 3% - 6% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 ~E:J ~~ [ill] ~ DO D Type 1 Type 2 Type 3 Type 4 Type 5 Measured Slump (inches) 5.75 Mix Design 1.0.: 7753 Placement Date: 12/08/2007 Weather Conditions: Mostly cloudy Time Sampled: 08:00am Batch time: Temperature. Air: 700F Concrete: 740F Truck No: 136 Ticket No: Air Content: 5.0% Unit Weight (pct): NA Overall Placement Location: Paving - 3rd section at north side of building VI - 60' north start, 120' end, grid line A/8.2-A/17.3 Sample Location: Gridline A/12.8 - 70' south Fracture Type Type2 Type2 Type2 Type2 Type 6 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (DMlKW) Page 6 of 11 Rone Engineering . Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214)630-9745 Report of Concrete Compressive Strength Test Report No.: 307701 Project No.: 0713408 Date of Service: 12/08/2007 Report Date: 02/05/2008 Project: Point West VI Coppell , Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Set No. Tested (days) (in) (in') (Ibs) (psi) 5 1 12/15/2007 7 6.00 28.27 119,610 4,230 5 2 01/05/2008 28 6.00 28.27 135,880 4,810 5 3 01/05/2008 28 6.00 28.27 139,700 4,940 Average 4,870 5 4 02/02/2008 56 6.00 28.27 156,900 5,550 Contractor: Duke Construction, LP Concrete Supplier: Potter Concrete Plant: On site Specification Requirements Strength: 4,000 psi @ 28 days Slump (in.): 4" - 6" Air (%): 3% - 6% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1 064 ASTM C-138 ASTM C-39 ~~ ~Q] ~ ~ DO D Type 1 Type 2 Type 3 Type 4 Type 5 PROJECT DATA Batch time: Concrete: 74 of Ticket No: Unit Weight (pet): NA Measured Slump (inches) 4.75 Mix Design I.D.: 7753 Placement Date: 12/08/2007 Weather Conditions: Clear Time Sampled: 09: 15am Temperature - Air: 690F Truck No: 131 Air Content: 4.5% Overall Placement Location: Paving - 3rd section at north side of building VI - 60' north start, 120' end, grid line A/8.2-A/17.3 Sample Location: Gridline A/11.5 - 120' north Fracture Type Type2 Type2 Type2 Type4 Type 6 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exdusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (DMlKW) Page 7 of 11 Rone Engineering . Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freldrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 307701 Project No.: 0713408 Date of Service: 12/08/2007 Report Date: 02/05/2008 Project: Point West VI Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA Contractor: Duke Construction, LP Concrete ')upplier: Potter Concrete Plant: On site Specification Req uirements Strength: 4,000 psi @ 28 days Slump (in.): 4" - 6" Air (%): 3% - 6% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 Measured Slump (inches) 6.0 Mix Design 1.0.: 7753 Placement Date: 12/08/2007 Weather Conditions: Windy, mostly cloudy Time Sampled: 10:01am Batch time: Temperature - Air: 690F Concrete: 740F Truck No: 126 Ticket No: Air Content: 4.9% Unit Weight (pet): NA Overall Placement Location: Paving - 3rd section at north side of building VI - 60' north start, 120' end, grid line A/8.2-A/17.3 Sample Location: Gridline A/10.7 - 85' north REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Fracture Set No. Tested (days) (in) (in') (Ibs) (psi) Type 6 1 12/15/2007 7 6.00 28.27 93,000 3,290 Type5 6 2 01/05/2008 28 6.00 28.27 119,190 4,220 Type2 6 3 01/05/2008 28 6.00 28.27 126,940 4,490 Type2 Average 4,350 6 4 02/02/2008 56 6.00 28.27 132,620 4,690 Type3 0~ ~[g [illj Q DO D Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written appnoval of Rone Engineering Services, Ltd. (DM/KW) Page 8 of 11 Rone Engineering . Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 307701 Project No.: 0713408 Date of Service: 12/08/2007 Report Date: 02/05/2008 Project: Point West VI Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA Contractor: Duke Construction, LP Concrete Supplier: Potter r.oncrete Plant: On site Specification Requirements Strength: 4,000 psi @ 28 days Slump (in.): 4" - 6" Air (%): 3% - 6% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 Measured Slump (inches) 5.0 Mix Design 1.0.: 7753 Placement Date: 12/08/2007 Weather Conditions: Windy, mostly cloudy Time Sampled: 11 :17am Batch time: Temperature - Air: 790F Concrete: 710F Truck No: 110 Ticket No: Air Content: 5.1 % Unit Weight (pcf): NA Overall Placement Location: Paving - 3rd section at north side of building VI - 60' north start, 120' end, grid line Al8.2-Al17.3 Sample Location: Gridline Al9.8 - 95' north REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Fracture Set No. Tested (days) (in) (in2) (Ibs) (psi) Type 7 1 12/15/2007 7 6.00 28.27 110,160 3,900 Type5 7 2 01/05/2008 28 6.00 28.27 166,660 5,890 Type2 7 3 01/05/2008 28 6.00 28.27 157,320 5,560 Type2 Average 5,730 7 4 02/02/2008 56 6.00 28.27 175,580 6,210 Type2 0~ ~~ [ill] t] DO D Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (DMIKW) Page 9 of 11 Rone Engineering . Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 307701 Project No.: 0713408 Date of Service: 12/08/2007 Report Date: 02/05/2008 Project: Point West VI Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA Contractor: Duke Construction, LP Concrete Supplier: P'Jtter Concrete Plant: On site Specification Requirements Strength: 4,000 psi @ 28 days Slump (in.): 4" - 6" Air (%): 3% - 6% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 Measured Slump (inches) 5.5 Mix Design I.D.: 7753 Placemer,t Date: 12/08/2007 Weather Conditions: Windy, mostly cloudy Time Sampled: 12:00pm Batch time: Temperature - Air: 800F Concrete: 720F Truck No: 144 Ticket No: Air Content: 4.5% Unit Weight (pcf): NA Overall Placement Location: Paving - 3rd section at north side of building VI - 60' north start, 120' end, grid line A/8.2-A/17.3 Sample Location: Gridline A/8.4 - 105' south REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Fracture Set No. Tested (days) (in) (in') (Ibs) (psi) Type 8 1 12/15/2007 7 6.00 28.27 112,100 3,960 Type2 8 2 01/05/2008 28 6.00 28.27 153,310 5,420 Type2 8 3 01/05/2008 28 6.00 28.27 152,280 5,390 Type2 Average 5,400 8 4 02/02/2008 56 6.00 28.27 185,230 6,550 Type3 Technician: Javier Martinez Started: 02:15am Report Distribution: Orig: Duke Construction, LP (Dallas, TX) Attn: Mr. Emmit Coots (1-ec copy) 1-ec Potter Concrete Attn: Mr Ryan Skelly 1-cc Pacheco Koch Consulting Engineers Attn: Mr. Jack Evans 1-cc City of Coppell Attn: Mr. Larry Davis 1-cc City of Coppell Attn: Mr. Lee Stone ~~ ~~ rnJ ~ DO D Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 Finished: 02:15pm Rone Engineering p-p.~ K. Scott Watson, AET Project Manager LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition. appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (DMlKW) Page 11 of 11 Rone Engineering . Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, 8te 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214} 630-9745 Report of Concrete Compressive Strength Test Report No.: 309761 Project No.: 0713408 Date ot Service: 01/05/2008 Report Date: 02/05/2008 Project: Point West VI Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Set No. Tested (days) (in) (in2) (Ibs) (psi) 1 1 01/12/2008 7 6.00 28.27 97,180 3,440 1 2 02/02/2008 28 6.00 28.27 135,790 4,800 1 3 02/02/2008 28 6.00 28.27 136,700 4,830 Average 4,820 4 03/01/2008 56 Contractor: Duke Construction, LP Concrete Supplier: Potter Concrete Plant: NA Specification Requirements Strength: 4,000 psi @ 28 days Slump (in.): 3" - 5" Air (%): NA Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1 064 ASTM C-138 ASTM C-39 ~~ ~~ 5TI] ~ DO D Type 1 Type 2 Type 3 Type 4 Type 5 Batch time: 03:38am Concrete: 600F Ticket No: 18039 Unit Weight (pet): NA Measured Slump (inches) 8.0 Mix Design I.D.: 7753PW6 Placement Date: 01/01'"/2008 Weather Conditions: NA Time Sampled: 04:02am Temperature - Air: 580F Truck No: 101 Air Content: 4.0% Overall Placement Location: Paving, South side of building, southeast corner to west building 600, grid lines 1-13/F-L Sample Location: Grid lines F-1 Fracture Type Type5 Type6 Type2 Type 6 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (KW/KW) Page 1 of 10 Rone Engineering . Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 309761 Project No.: 0713408 Date of Service: 01/05/2008 Report Date: 02/05/2008 Project: Point West VI Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Set No. Tested (days) (in) (in') (Ibs) (psi) 2 1 01/12/2008 7 6.00 28.27 96,780 3,420 2 2 02/02/2008 28 6.00 28.27 137,510 4,860 2 3 02/02/2008 28 6.00 28.27 138,220 4,890 Average 4,880 2 4 03/01/2008 56 Contractor: Duke Construction, LP Concrete Supplier: Potter Concrete Plant: NA Specification Requirements Strength: 4,000 psi @ 28 days Slump (in.): 3" - 5" Air (%): NA Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 ~E:] ~~ [ill] ~ DO D Type 1 Type 2 Type 3 Type 4 Type 5 Batch time: 04:21am Concrete: 580F Ticket No: 18049 Unit Weight (pet): NA Measured Slump (inches) 6.0 Mix Design I.D.: 7753PW6 Plar:ement Date: 01/05/2008 Wedther Conditions: NA Time Sampled: 04:30am Temperature - Air: 600F Truck No: 126 Air Content: 2.2% Overall Placement Location: Paving, South side of building, southeast corner to west building 600, grid lines 1-13/F-L Sample Location: Grid lines G-3 Fracture Type Type6 Type6 Type5 Type 6 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (KW/KW) Page 2 of 10