Duke Lesley 1A-LR080125 Rone Engineering . Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 311045 Project No.: 0713408 Date of Service: 01/17/2008 Report Date: 01/25/2008 Project: Point West VI Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA Contractor: Duke Construction, LP Concrete Supplier: Potter Concre'9 Plant: 1 Specification Requirements Strength: 4,000 psi @ 28 days Slump (in.): 3" - 5" Air (%): 3% - 5% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1 064 ASTM C-138 ASTM C-39 Mix Design I.D.: 7753 Placement Date: 01/17/2008 Weather Conditions: Clear Time Sampled: 03:30am Temperature - Air: 340F Truck No: 103 Air Content: 3.8% Overall Placement Location: Parking lot paving - north side of building 6 Batch time: 03:09am Concrete: 470F Ticket No: 18673 Unit Weight (pet): NA Measured Slump (inches) 6.0 Sample Location: 950' west from northwest corner of building 6 - center Concrete Compressive Cylinder 6" x 12" Maximum Load (Ibs) 89,530 Area (in2) 28.27 Type 6 REPORT OF TESTS Compressive Strength (psi) 3,170 Fracture Type Type6 Cylinder Marked Date Set No. Tested 1 1 01/24/2008 1 2 02/14/2008 1 3 02/14/2008 1 4 03/13/2008 Age (days) 7 Diameter (in) 6.00 28 28 56 ~EJ ~QJ 5IE EJ DO 0 Type 1 Type 2 Type 3 Type 4 Type 5 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition. appearance. etc.) or any other feature of similar SUbject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (CH/KW) Page 1 of 9 Rone Engineering . Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrtch, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 311045 Project No.: 0713408 Date of Service: 01/17/2008 Report Date: 01/25/2008 Project: Point West VI Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA Contractor: Duke Construction, LP Concrete Supplier: P,tter Concrete Plant: 1 Specification Requirements Strength: 4,000 psi @ 28 days Slump (in.): 3" - 5" Air (%): 3% - 5% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 Mix Design 1.0.: 7753 Placement Date: 01/17/2008 Weather Conditions: Clear Time Sampled: 04:25am Temperature - Air: 310F Truck No: 135 Air Content: 3.7% Overall Placement Location: Parking lot paving - north side of building 6 Sample Location: 992' west from northeast corner of building 6 REPORT OF TESTS Batch time: 04:13am Concrete: 470F Ticket No: 18687 Unit Weight (pcf): NA Measured Slump (inches) 5.0 Cylinder Marked Date Set No. Tested 2 1 01/24/2008 2 2 02/14/2008 2 3 02/14/2008 2 4 03/13/2008 Age (days) 7 Diameter (in) 6.00 28 28 56 ~Ej ~[g ~ E;J DO D Type 1 Type 2 Type 3 Type 4 Type 5 Concrete Compressive Cylinder 6" x 12" Maximum Load (Ibs) 106,680 Area (in2) 28.27 Type 6 Compressive Strength (psi) 3,770 Fracture Type Type6 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (CH/KW) Page 3 of 9 Rone Engineering . Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 311045 Project No.: 0713408 Date of Service: 01/17/2008 Report Date: 01/25/2008 Project: Point West VI Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PRO,'ECT DATA Contractor: Duke Construction, LP Concrete Supplier: Potter Concrete Plant: 1 Specification Requirements Strength: 4,000 psi @ 28 days Slump (in.): 3" - 5" Air (%): 3% - 5% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 Mix Design I.D.: 7753 Plarement Date: 01/17/2008 Weather Conditions: Clear Time Sampled: 05:22am Temperature - Air: 290F Truck No: 126 Air Content: 3.8% Overall Placement Location: Parking lot paving - north side of building 6 Sample Location: 1024' west from northwest corner of building 6 REPORT OF TESTS Batch time: 05:00am Concrete: 430F Ticket No: 18697 Unit Weight (pcf): NA Measured Slump (inches) 5.5 Cylinder Marked Date Set No. Tested 3 1 01/24/2008 3 2 02/14/2008 3 3 02/14/2008 3 4 03/13/2008 Age (days) 7 Diameter (in) 6.00 28 28 56 I2JrJ ~l9 5ffi E;J DO 0 Type 1 Type 2 Type 3 Type 4 Type 5 Concrete Compressive Cylinder 6" x 12" Maximum Load (Ibs) 94,500 Area (in2) 28.27 Type 6 Compressive Strength (psi) 3,340 Fracture Type Type6 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (CH/KW) Page 5 of 9 Rone Engineering . Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 311045 Project No.: 0713408 Date of Service: 01/17/2008 Report Date: 01/25/2008 Project: Point West VI Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. Contractor: Duke Construction, LP Concrete Supplier: Potter Concrete Plant: 1 Specification Requirements Strength: 4,000 psi @ 28 days Slump (in.): 3" - 5" Air (%): 3% - 5% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 PROJECT DATA Mix Design I.D.: 7753 Placement Date: 01/17/2008 Weather Conditions: Clear Time Sampled: 06:20am Temperature - Air: 280F Truck No: 126 Air Content: 3.5% Overall Placement Location: Parking lot paving - north side of building 6 Measured Slump (inches) 5.0 Batch time: 05:56am Concrete: 430F Ticket No: 18707 Unit Weight (pct): NA Sample Location: 1064' west from northwest corner of building 6 REPORT OF TESTS Cylinder Marked Date Set No. Tested 4 1 01/24/2008 4 2 02/14/2008 4 3 02/14/2008 4 4 03/13/2008 Age (days) 7 Diameter (in) 6.00 28 28 56 ~l3 ~~ 5TIJ [SJ DO 0 Type 1 Type 2 Type 3 Type 4 Type 5 Concrete Compressive Cylinder 6" x 12" Maximum Load (Ibs) 144,010 Compressive Strength (psi) 5,090 Fracture Type Type2 Area (in2) 28.27 Type 6 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar SUbject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (CH/KW) Page 7 of 9 Rone Engineering . Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 310881 Project No.: 0713408 Date of Service: 01/16/2008 Report Date: 01/25/2008 Project: Point West VI Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA Contractor: Duke Construction, LP Concrete Supplier: Potter Concrete Plant: 1 Specification Requirements Strength: 4,000 psi @ 28 days Slump (in.): 4" - 6" Air (%): 3% - 6% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 Measured Slump (inches) Mix Design 1.0.: 7753 PW6 Placement Pate: 01/16/2008 Weather Conditions: Clear Time Sampled: 06:20am Temperature - Air: Truck No: 103 Air Content: NA Overall Placement Location: Paving for west side of building 6 - start location is 1000' south from northwest corner, 100' west, 100' (continue) Sample Location: 50' south, 40' west from start location REPORT OF TESTS Batch time: 06:05am Concrete: Ticket No: 18612 Unit Weight (pet): NA Cylinder Marked Date Set No. Tested 1 1 01/23/2008 1 2 02/13/2008 1 3 02/13/2008 4 03/12/2008 Age (days) 7 Diameter (in) 6.00 28 28 56 o r=J [!1J[g fill] E;] DO 0 Type 1 Type 2 Type 3 Type 4 Type 5 Concrete Compressive Cylinder 6" x 12" Maximum Load (Ibs) 124,730 Area (in2) 28.27 Type 6 Compressive Strength (psi) 4,410 Fracture Type Type2 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (CHIKW) Page 1 of 13 Rone Engineering . Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 310881 Project No.: 0713408 Date of Service: 01/16/2008 Report Date: 01/25/2008 Project: Point West VI Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PPOJECT DATA Contractor: Duke Construction, LP Concrete Supplier: Potter Concrete Plant: 1 Specification Requirements Strength: 4,000 psi @ 28 days Slump (in.): 4" - 6" Air (%): 3% - 6% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1 064 ASTM C-138 ASTM C-39 Batch time: 07:05am Concrete: 600F Ticket No: 18619 Unit Weight (pct): NA Measured Slump (inches) 6.5 Mix Design 1.0.: 7753 PW6 Placement Date: 01/16/2008 Weather Conditions: Clear Time Sampled: 07:15am Temperature - Air: 480F Truck No: 135 Air Content: 6.5% Overall Placement Location: Paving for west side of building 6 - start location is 1000' south from northwest corner, 100' west, 100' (continue) Concrete Compressive Cylinder 6" x 12" Maximum Load (Ibs) 115,390 Area (in2) 28.27 Type 6 Sample Location: North from 9th set of ballards from north ramp, 90' west from building REPORT OF TESTS Compressive Strength (psi) 4,080 Fracture Type Type3 Cylinder Marked Date Set No. Tested 2 1 01/23/2008 2 2 02/13/2008 2 3 02/13/2008 2 4 03/12/2008 Age (days) 7 Diameter (in) 6.00 28 28 56 ~EJ ~[g 5IE [S] DO 0 Type 1 Type 2 Type 3 Type 4 Type 5 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition. appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (CH/KW) Page 3 of 13 Rone Engineering . Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 310881 Project No.: 0713408 Date of Service: 01/16/2008 Report Date: 01/25/2008 Project: Point West VI Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA Contractor: Duke Construction, LP Concrete Supplier: Potter Concrete Plant: 1 Specification Requirements Strength: 4,000 psi @ 28 days Slump (in.): 4" - 6" Air (%): 3% - 6% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1 064 ASTM C-138 ASTM C-39 Batch time: 07:49am Concrete: 600F Ticket No: 18629 Unit Weight (pet): NA Measured Slump (inches) 6.5 Mix Design 1.0.: 7753 PW6 Placemert Date: 01/16/2008 Weather ~onditions: Clear Time Sampled: 08:00am Temperature - Air: 490F Truck No: 139 Air Content: 6.5% Overall Placement Location: Paving for west side of building 6 - start location is 1000' south from northwest corner, 100' west, 100' (continue) Area (in2) 28.27 Type 6 Sample Location: South of 9th set of ballards from north ramp. 90' west from building REPORT OF TESTS Compressive Strength (psi) 3,710 Fracture Type Type2 Concrete Compressive Cylinder 6" x 12" Maximum Load (Ibs) 104,880 Cylinder Marked Date Set No. Tested 3 1 01/23/2008 3 2 02/13/2008 3 3 02/13/2008 3 4 03/12/2008 Age (days) 7 Diameter (in) 6.00 28 28 56 ~r3 ~QJ 5J] [SJ DO D Type 1 Type 2 Type 3 Type 4 Type 5 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (CH/KW) Page 5 of 13 Rone Engineering . Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214)630-9745 Report of Concrete Compressive Strength Test Report No.: 310881 Project No.: 0713408 Date of Service: 01/16/2008 Report Date: 01/25/2008 Project: Point West VI Coppell , Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. Contractor: Duke Construction, LP Concrete Supplier: Potter Concrete Plant: 1 Specification Requirements Strength: 4,000 psi @ 28 days Slump (in.): 4" - 6" Air (%): 3% - 6% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 PROJECT DATA Batch time: 08:48am Concrete: 640F Ticket No: 18641 Unit Weight (pet): NA Measured Slump (inches) 6.5 Mix Design I.D.: 7753 PW6 Placement Date: 01/16/2008 Weather Conditions: Cloudy Time Sampled: 09:00am Temperature - Air: 450F Truck No: 139 Air Content: 5.4% Overall Placement Location: Paving for west side of building 6 - start location is 1000' south from northwest corner, 100' west, 100' (continue) Sample Location: 660' south, 10' west from start location REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Maximum Load (lbs) 129,410 Cylinder Marked Date Set No. Tested 4 1 01/23/2008 4 2 02/13/2008 4 3 02/13/2008 4 4 03/12/2008 Age (days) 7 Diameter (in) 6.00 28 28 56 ~tj [g]~ [llij ~ DO D Type 1 Type 2 Type 3 Type 4 Type 5 Area (in') 28.27 Compressive Strength (psi) 4,580 Fracture Type Type2 Type 6 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (CH/KW) Page 7 of 13 Rone Engineering .. Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 310881 Project No.: 0713408 Date of Service: 01/16/2008 Report Date: 01/25/2008 Project: Point West VI Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA Contractor: Duke Construction, LP Conc--ete Supplier: Potter Concrete Plant: 1 Specification Requirements Strength: 4,000 psi @ 28 days Slump (in.): 4" - 6" Air (%): 3% - 6% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ' ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 Batch time: 09:53am Concrete: 630F Ticket No: 18651 Unit Weight (pcf): NA Measured Slump (inches) 6.75 Mix Design I.D.: 7753 PW6 Placement Date: 01/16/2008 Weather Conditions: Cloudy Time Sampled: 10:30am Temperature - Air: 470F Truck No: 133 Air Content: 4.2% Overall Placement Location: Paving for west side of building 6 - start location is 1000' south from northwest corner, 100' west, 100' (continue) Concrete Compressive Cylinder 6" x 12" Maximum Load (Ibs) 116,410 Area (in') 28.27 Type 6 Sample Location: 800' south, 40' west from start location REPORT OF TESTS Compressive Strength (psi) 4,120 Fracture Type Type2 Cylinder Marked Date Set No. Tested 5 1 01/23/2008 5 2 02/13/2008 5 3 02/13/2008 5 4 03/12/200B Age (days) 7 Diameter (in) 6.00 28 28 56 ~E:3 ~~ [ill] E;] DO 0 Type 1 Type 2 Type 3 Type 4 Type 5 L1MrrA TIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (CHIKW) Page 9 of 13 Rone Engineering . Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 310881 Project No.: 0713408 Date of Service: 01/16/2008 Report Date: 01/25/2008 Project: Point West VI Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA Contractor: Duke Construction, LP Concrete Supplier: Potter Concrete Plant: 1 Specification Requirements Strength: 4,000 psi @ 28 days Slump (in.): 4" - 6" Air (%): 3% - 6% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 Batch time: 11 :04am Concrete: 680F Ticket No: 18661 Unit Weight (pct): NA Measured Slump (inches) 5.75 Mix Design 1.0.: 7753 PW6 Placement Date: 01/16/2008 Weather Conditions: Cloudy Time Sampled: 11 :35am Temperature - Air: 480F Truck No: 135 Air Content: 3.3% Overall Placement Location: Paving for west side of building 6 - start location is 1000' south from northwest corner, 100' west, 100' (continue) Sample Location: 900' south, 35' west from start location REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Maximum Load (Ibs) 120,680 Cylinder Marked Date Set No. Tested 6 1 01/23/2008 6 2 02/13/2008 6 3 02/13/2008 6 4 03/12/2008 Age (days) 7 Diameter (in) 6.00 28 28 56 f:8JE3 ~~ ill] [;J DO D Type 1 Type 2 Type 3 Type 4 Type 5 Area (in') 28.27 Compressive Strength (psi) 4,270 Fracture Type Type2 Type 6 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (CH/KW) Page 11 of 13