Loading...
Duke Lesley 3C-LR080211 Rone Engineering . Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 312403 Project No.: 0711530 Date of Service: 02/01/2008 Report Date: 02/11/2008 Project: Point West Office I Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA Contractor: Duke Construction, LP Concrete Supplier: Potter Concrete Plant: 1 Specification Requirements Strength: 3,000 psi @ 28 days Slump (in.): 3" - 5" Air (%): 3% - 6% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 Batch time: Concrete: 620F Ticket No: 1~ 141 Unit Weight (pcf): NA Measured Slump (inches) 4.5 Mix Design 1.0.: 7550PW Placement Date: 02/01/2008 Wr.ather Conditions: Sunny Time Sampled: 10:00am Temperature - Air: 540F Truck No: 137 Air Content: 7.5% Overall Placement Location: Sidewalks, Dividend and Beltline, north and east of Point West 2, city sidewalks Sample Location: Northeast and southeast corner of Dividend and Beltline REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Fracture Set No. Tested (days) (in) (in') (Ibs) (psi) Type 1 1 02/08/2008 7 6.00 28.27 109,770 3,880 Type2 1 2 02/29/2008 28 1 3 02/29/2008 28 4 03/28/2008 56 ~tJ ~[g ~ lJ DO D Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 Started: 09:30am Finished: 11 :OOam Technician: Alejandro Avendano Report Distribution: Orig: Duke Construction, LP (Dallas, TX) Attn: Mr. David Miller (1-ec copy) 1-ec Duke Construction, LP Attn: Mr. Jason Sulzener 1-cc City of Coppell Attn: Mr. Larry Davis 1-cc City of Coppell Attn: Mr. Lee Stone 1-cc Potter Concrete Attn: Mr Ryan Skelly Rone Engineering ft~~ K. Scott Watson, AET Project Manager LIMITATIONS: The test resulls presented herein were prepared based upon the specifiC samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (TMlKW) Page 1 of 1