Duke Lesley 2A-LR080211 Rone Engineering . Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 310431 Project No.: 0712932 Date of Service: 01/11/2008 Report Date: 02/11/2008 Project: Hemisphere's at Point West) .a, A Coppell, Texas . Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Set No. Tested (days) (in) (in') (Ibs) (psi) 1 1 01/18/2008 7 6.00 28.27 119,480 4,230 1 2 02/08/2008 28 6.00 28.27 156,370 5,530 1 3 02/08/2008 28 6.00 28.27 164,430 5,820 Average 5,670 1 4 03/07/2008 56 Contractor: Duke Construction, LP Concrete Supplier: Potter Concrete Plant: 1 Specification Requirements Strength: 4,000 psi @ 28 days Slump (in.): 4" - 6" Air (%): 3% - 5% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1 064 ASTM C-138 ASTM C-39 ~tJ ~~ 5IE E:] DO D Type 1 Type 2 Type 3 Type 4 Type 5 Mix Design 1.0.: 7753PW Pla-:ement Date: 01/11/2008 Weather Conditions: Clear Time Sampled: 05:00am Temperature - Air: 370F Truck No: 125 Air Content: 4.1 % Overall Placement Location: Paving, 75' away from building on south side from grid line 15-22/L Measured Slump (inches) 4.75 Batch time: 04:41 am Concrete: 500F Ticket No: 18297 Unit Weight (pcf): NA Sample Location: Grid line 22/L Fracture Type Type6 Type3 Type2 Type 6 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for lesting. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (TMfKW) Page 1 of 10 Rone Engineering . Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 310431 Project No.: 0712932 Date of Service: 01/11/2008 Report Date: 02/11/2008 Project: Hemisphere's at Point West Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Set No. Tested (days) (in) (in2) (Ibs) (psi) 2 1 01/18/2008 7 6.00 28.27 115,400 4,080 2 2 02/08/2008 28 6.00 28.27 161,510 5,710 2 3 02/08/2008 28 6.00 28.27 154,960 5,480 Average 5,600 2 4 03/07/2008 56 Contractor: Duke Construction, LP Concrete Supplier: Potter Concrete Plant: 1 Specification Requirements Strength: 4,000 psi @ 28 days Slump (in.): 4" - 6" Air (%): 3% - 5% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 ~~ ~[g 51] t] DO D Type 1 Type 2 Type 3 Type 4 Type 5 Mix Design I.D.: 7753PW Placement Date: 01/11/2008 Weather Conditions: Clear Time Sampled: 05:45am Temperature - Air: 370F Truck No: 130 Air Content: 4.3% Overall Placement Location: Paving, 75' away from building on south side from grid line 15-22/L Measured Slump (inches) 4.75 Batch time: 05:30am Concrete: 500F Ticket No: 18307 Unit Weight (pet): NA Sample Location: Grid line U21 Fracture Type Type2 Type6 Type2 Type 6 L1MrTA TIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (TMIKW) Page 2 of 10 Rone Engineering . Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 310431 Project No.: 0712932 Date of Service: 01/11/2008 Report Date: 02/11/2008 Project: Hemisphere's at Point West Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA Contractor: Duke Construction, LP Concrete Supplier: Potter Concrete Plant: 1 Specification Requirements Strength: 4,000 psi @ 28 days Slump (in.): 4" - 6" Air (%): 3% - 5% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1 064 ASTM C-138 ASTM C-39 Mix Design 1.0.: 7753PW Placement Date: 01/11/2008 Weather Co nditions: Clear Time Sampled: 06:40am Temperature - Air: 370F Truck No: 129 Air Content: 4.6% Overall Placement Location: Paving, 75' away from building on south side from grid line 15-221L Measured Slump (inches) 5.5 Batch time: 06:30am Concrete: 520F Ticket No: 18320 Unit Weight (pet): NA Sample Location: Grid line U19.5 REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Fracture Set No. Tested (days) (in) (in2) (Ibs) (psi) Type 3 1 01/18/2008 7 6.00 28.27 88,600 3,130 Type6 3 2 02/08/2008 28 6.00 28.27 128,740 4,550 Type2 3 3 02/08/2008 28 6.00 28.27 134,020 4,740 Type6 Average 4,650 3 4 03/07/2008 56 0E3 ~QJ Ern E;] DO D Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition. appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (TMIKW) Page 3 of 10 Rone Engineering . Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 310431 Project No.: 0712932 Date of Service: 01/11/2008 Report Date: 02111/2008 Project: Hemisphere's at Point West Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Set No. Tested (days) (in) (in') (Ibs) (psi) 4 1 01/18/2008 7 6.00 28.27 99,220 3,510 4 2 02/08/2008 28 6.00 28.27 135,230 4,780 4 3 02/08/2008 28 6.00 28.27 129,230 4,570 Average 4,680 4 4 03/07/2008 56 Contractor: Duke Construction, LP Concrete Supplier: Potter Concrete Plant: 1 Specification Requirements Strength: 4,000 psi @ 28 days Slump (in.): 4" - 6" Air (%): 3% - 5% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1 064 ASTM C-138 ASTM C-39 0tJ ~[g 5IE E;] DO 0 Type 1 Type 2 Type 3 Type 4 Type 5 PROJECT DATA Mix Design I.D.: 7753PW Placement Date: 01/11/2008 Weather Conditions: Sunny, clear Time Sampled: 07:20am Batch time: 06:57am Temperature - Air: 400F Concrete: 520F Truck No: 138 Ticket No: 18326 Air Content: 4.4% Unit Weight (pet): NA Overall Placement Location: Paving, 75' away from building on south side from grid line 15-22/L Measured Slump (inches) 5.25 Sample Location: Grid lines U18.25 Fracture Type Type6 Type6 Type2 Type 6 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (TMIKWl Page 5 of 10 Rone Engineering . Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 310431 Project No.: 0712932 Date of Service: 01/11/2008 Report Date: 02/11/2008 Project: Hemisphere's at Point West Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Set No. Tested (days) (in) (in') (Ibs) (psi) 5 1 01/18/2008 7 6.00 28.27 99,720 3,530 5 2 02/08/2008 28 6.00 28.27 149,050 5,270 5 3 02/08/2008 28 6.00 28.27 147,200 5,210 Average 5,240 5 4 03/07/2008 56 Contractor: Duke Construction, LP Concrete Supplier: Potter Concrete Plant: 1 Specification Requirements Strength: 4,000 psi @ 28 days Slump (in.): 4" - 6" Air (%): 3% - 5% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 ~E3 ~[g rnJ E] DO D Type 1 Type 2 Type 3 Type 4 Type 5 PROJECT DATA Mix Design 1.0.: 7753PW Placement Date: 01/11/2008 Weather Conditions: Sunny, clear Time Sampled: 08:20am Batch time: 08:04am Temperature - Air: 400F Concrete: 540F Truck No: 125 Ticket No: 18339 Air Content: 4.4% Unit Weight (pcf): NA Overall Placement Location: Paving, 75' away from building on south side from grid line 15-22/L Measured Slump (inches) 5.0 Sample Location: Grid lines L/17.5 Fracture Type Type6 Type2 Type5 Type 6 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written appnoval of Rone Engineering Services. Ltd. (TlvIfKW) Page 7 of 10 Rone Engineering . Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 310431 Project No.: 0712932 Date of Service: 01/11/2008 Report Date: 02/11/2008 Project: Hemisphere's at Point West Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Set No. Tested (days) (in) (in') (Ibs) (psi) 6 1 01/18/2008 7 6.00 28.27 100,320 3,550 6 2 02/08/2008 28 6.00 28.27 156,730 5,540 6 3 02/08/2008 28 6.00 28.27 156,980 5,550 Average 5,550 6 4 03/07/2008 56 Contractor: Duke Construction, LP Concrete Supplier: Potter Concrete Plant: 1 Specification Requirements Strength: 4,000 psi @ 28 days Slump (in.): 4" - 6" Air (%): 3% - 5% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1 064 ASTM C-138 ASTM C-39 0~ ~Q] DIE bJ DO D Type 1 Type 2 Type 3 Type 4 Type 5 PROJECT DATA Mix Design 1.0.: 7753PW Placement Date: 01/11/2008 Weather Conditions: Sunny, clear Time Sampled: 09:40am Batch time: 09:15am Temperature - Air: 410F Concrete: 550F Truck No: 138 Ticket No: 18347 Air Content: 4.2% Unit Weight (pet): NA Overall Placement Location: Paving, 75' away from building on south side from grid line 15-22fL Measured Slump (inches) 5.0 Sample Location: Grid lines U15 Fracture Type Type5 Type5 Type3 Type 6 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (TM/KW) Page 9 of 10 Rone Engineering . Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 310502 Project No.: 0712932 Date of Service: 01/11/2008 Report Date: 02/11/2008 Project: Hemisphere's at Point West Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perfonm required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Set No. Tested (days) (in) (in') (Ibs) (psi) 1 1 01/18/2008 7 6.00 28.27 110,280 3,900 1 2 02/08/2008 28 6.00 28.27 142,180 5,030 1 3 02/08/2008 28 6.00 28.27 146,110 5,170 Average 5,100 1 4 03/07/2008 56 Technician: Montreal Bailey Rone Engineering See Report 310431 for technician time~~ Report Distribution: . . . . Orig: Duke Construction, LP (Dallas, TX) Attn: Mr. Paul Byrne .. . ... . . ... . ...... (1-ec copy) .... - 1-cc Potter Concrete Attn: Mr Ryan Skelly K. Scott Watson, AET 1-cc C~ty of Coppell Attn: Mr. Lee Stone. Project Manager 1-cc City of Coppell Attn: Mr. Larry DavIs Contractor: Duke Construction, LP Concrete Supplie.': Potter Concrete Plant: 1 Specification Requirements Stength: 3,000 psi @ 28 days Slump (in.): 4" - 6" Air (%): 3% - 5% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1 064 ASTM C-138 ASTM C-39 ~L3 ~.ull ~l.~ Type 2 mE 5J DO D Type 1 Type 3 Type 4 Type 5 PROJECT DATA Mix Design I.D.: 7750PW Placement Date: 01/11/2008 Weather Conditions: Sunny, clear Time Sampled: 11:35am Batch time: 10:49am Temperatue - Air: 520F Concrete: 680F Truck No: 141 Ticket No: 18355 Air Content: 3.8% Unit Weight (pet): NA Overall Placement Location: Sidewalk at Point West VII, east side of building Measured Slump (inches) 4.5 Sample Location: 20' east, 10' north from southeast building corner Fracture Type Type5 Type5 Type5 Type 6 ~ L1MITA nONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (KW/KW) Page 1 of 1