Duke Lesley 1A-LR080213 Rone En~~ Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 310748 Project No.: 0713408 Date of Service: 01/15/2008 Report Date: 02/13/2008 Project: Point West VI Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Set No. Tested (days) (in) (in') (Ibs) (psi) 1 1 01/22/2008 7 5.98 28.09 76,830 2,740 1 2 02/12/2008 28 6.00 28.27 124,430 4,400 1 3 02/12/2008 28 6.00 28.27 129,020 4,560 Average 4,480 4 03/11/2008 56 Contractor: Duke Construction, LP Concrete Supplier: Potter Concrete Plant: 1 Specification Requirements Strength: 4,000 psi @ 28 days Slump (in.): 4" - 6" Air (%): NA Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 t~~J [~ f~~:~l L~] 57J'71 ~' I i "&[J Type 3 t~~J [""'11 .J' [7~J' ------~j ..... ". ...,,",...., -...-~--~.- -..,-.--. Type 1 Type 2 Type 4 Type 5 PROJECT DATA Mix Design 1.0.: 7753 PW6 Placement Date: 01/15/2008 Weather Conditions: Partly cloudy Time Sampled: 10:23am Batch time: 09:59am Temperature - Air: 510F Concrete: 570F Truck No: 133 Ticket No: 18540 Air Content: 5.5% Unit Weight (pet): NA Overall Placement Location: Southeast fire lane paving and south approach paving Measured Slump (inches) 9.5 Sample Location: 210' west, B' south from northeast corner Fracture Type Type2 Type6 Type2 Type 6 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (CH/KW) Page 1 of 4 Rone En~~ 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 Report of Concrete Compressive Strength Test Report No.: 310748 Project No.: 0713408 Date of Service: 01/15/2008 Report Date: 02/13/2008 Project: Point West VI Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. Contractor: Duke Construction, LP Concrete Supplier: Potter Concrete Plant: 1 Specification Requirements Strength: 4,000 psi @ 28 days Slump (in.): 4" - 6" Air (%): NA Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 PROJECT DATA Mix Design 1.0.: 7753 PW6 Placement Date: 01/15/2008 Weather Conditions: Partly cloudy Time Sampled: 11 :20am Batch time: 10:49am Temperature - Air: 520F Concrete: 620F Truck No: 138 Ticket No: 18549 Air Content: 5.2% Unit Weight (pcf): NA Overall Placement Location: Southeast fire lane paving and south approach paving Measured Slump ,inches) 8.5 Sample Location: 45' east, 6' north from southeast corner REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Fracture Set No. Tested (days) (in) (in2) (Ibs) (psi) Type 2 1 01/22/2008 7 6.00 28.27 92,930 3,290 Type6 2 2 02/12/2008 28 6.00 28.27 1 31 , 150 4,640 Type6 2 3 02/12/2008 28 6.00 28.27 134,340 4,750 Type6 Average 4,690 2 4 03/11/2008 56 l~rl ~~ EllJ ~ [][] D Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (CH/KW) Page 2 of 4 Rone En~== Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 310748 Project No.: 0713408 Date of Service: 01/15/2008 Report Date: 02/13/2008 Project: Point West VI Coppell, Texas Services: ObtaiA samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. Contractor: Duke Construction, LP Concrete Supplier: Potter Concrete Plant: 1 Specification Requirements Strength: 4,000 psi @ 28 days Slump (in.): 4" - 6" Air (%): NA Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 PROJECT DATA Mix Design 1.0.: 7753 PW6 Placement Date: 01/15/2008 Weather Conditions: Partly cloudy Time Sampled: 12:20pm Batch time: 11:16am Temperature - Air: 600F Concrete: 610F Truck No: 139 Ticket No: 18554 Air Content: 4.8% Unit Weight (pcf): NA Overall Placement Location: Southeast fire lane paving and south approach paving Measured Slump (inches) 7.5 Sample Location: 30' south, 10' east from northwest corner REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Maximum Compressive Age Diameter Area Load Strength Fracture (days) (in) (in') (Ibs) (psi) Type 7 6.00 28.27 91,610 3,240 Type6 28 6.00 28.27 134,390 4,750 Type6 28 6.00 28.27 141,980 5,020 Type2 Average 4,890 Cylinder Marked Set No. - - 3 1 Date Tested 01/22/2008 3 3 2 3 02/12/2008 02/12/2008 3 4 03/11/2008 56 k~~ l?51 ~l] [1:::] '~t ;r~ t~'J L~~J l~~] [J Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 LIMITATIONS: The test results presented herein were prepared based upon the specifiC samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no controL Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, ltd. (CHIKW) Page 3 of 4