Loading...
Duke Lesley-LR080215 Rone Engineering . 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 Report of In-Place Density Testing Report No.: 313567 Project No.: 0612510 Date of Service: 02/14/2008 Report Date: 02/15/2008 Project: Lesley Infrastructure Services: Perform In-Place Density Testing PROJECT DATA Contractor: Test Method: ASTM ~1.1.<- Gauge: Troxler 3430 Gauge Serial No: 35518 Test Mode: DT Standard Counts Moisture Density Current: 727 Current: 2519 Previous: 731 Previous: 2508 Maximum Moisture Density Project Requirements MID No. % (pet) Moisture Density 272998 Brown I Silty Clay wI Organics 22.5 96.5 Optimum +4 95 min FIELD DENSITY TESTS Test Probe MID Moisture Wet Density Dry Density Density No Test Location Depth No. % (pet) ( pet) (%max) - Fill 100' east, 100' south from northwest corner, l' 6" 272998 24.0 116.3 93.8 97 below grade Fill 2 100' east, 200' south from northwest corner, l' 6" 272998 24.1 116.5 93.9 97 below grade Fill 3 100' east, 300' south from northwest corner, l' 6" 272998 23.6 116.9 94.6 98 below grade Fill 4 100' east, 400' south from northwest corner, l' 6" 272998 23.9 117.1 94.5 98 below grade Fill 5 100' east, 500' south from northwest corner, l' 6" 272998 23.2 116.9 94.9 98 below grade Fill 6 200' east, 100' south from northwest corner, l' 6" 272998 23.7 117.3 94.8 98 below grade Fill 7 200' east, 200' south from northwest corner, l' 6" 272998 24.9 116.9 93.6 97 below grade LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services. Ltd. (KW/KW) Page 1 of 2 Rone Engineering . 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 Report of In-Place Density Testing Report No.: 313567 Project No.: 0612510 Date of Service: 02/14/2008 Report Date: 02/15/2008 Project: Lesley Infrastructure Services: Perform In-Place Density Testing FIELD DENSITY TESTS Test Probe MID Moisture Wet Density Dry Density Density No Test Location Depth No. % (pcf) (pef) (% max) - Fill 8 200' east, 300' south from northwest corner, l' 6" 272998 26.3 117.7 93.2 97 below grade Fill 9 200' east, 400' south from northwest corner, l' 6" 272998 24.6 117.5 94.3 98 below grade Fill 10 200' east, 500' south from northwest corner, l' 6" 272998 24.4 117.8 94.7 98 below grade Fill 11 300' east, 100' south from northwest corner, l' 6" 272998 26.0 117.8 93.5 97 below grade Fill 12 300' east, 200' south from northwest corner, l' 6" 272998 25.5 118.1 94.1 98 below grade Fill 13 300' east, 300' south from northwest corner, l' 6" 272998 24.9 117.7 94.2 98 below grade Fill 14 300' east, 400' south from northwest corner, l' 6" 272998 24.9 117.4 94.0 97 below grade Fill 15 300' east, 500' south from northwest corner, l' 6" 272998 24.7 117.5 94.2 98 below grade Fill 16 400' east, 100' south from northwest corner, l' 6" 272998 22.9 117.2 95.4 99 below grade Technician: Joe Jernigan Report Distribution: Orig: Duke Construction, LP (Dallas, TX) AUn: Mr. Alex Bennett PE (1-ec copy) 1-ec Lacy Construction Attn: Mr. Kevin Briles 1-cc City of Coppell Attn: Mr. Lee Stone 1-cc City of Coppell Attn: Mr. Larry Davis Started: 07:15am Finished: 10:15am Rone Engineering paZif ~ K. Scott Watson, AET Project Manager LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (KW/KW) Page 2 of 2