Gateway BP(3.1)-LR080305 Rone Engineering . Client: Transwestern Co 5001 Spring Va Dallas, TX 7 44 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 -- Report of Concrete Compressive Strength Test Report No.: 312633 Project No.: 0712786 Date of Service: 02/04/2008 Report Date: 03/05/2008 Project: Gateway Business Center Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA Contractor: Constructors & Associates Concrete Supplier: Redi-Mix Plant: P136 Specification Requirements Strength: 3,500 psi @ 28 days Slump (in.): 4" maximum Air (%): NA Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 Measured Slump (inches) 4.0 Mix Design 1.0.: 23501501 Placement Date: 02/04/2008 Weather Conditions: Partly cloudy, windy Time Sampled: 03:05pm Batch time: Temperature -Air: 770F Concrete: 780F Truck No: 1033 Ticket No: 13606929 Air Content: 1.0% Unit Weight (pcf): NA Overall Placement Location: Monument signs, east side of building at north and south entrances from southbound Freeport Pkwy. Sample Location: Same as above REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Fracture Set No. Tested (days) (in) (in2) (Ibs) (psi) Type 1 1 02/11/2008 7 6.02 28.46 92,830 3,260 Type2 1 2 03/03/2008 28 6.00 28.27 127,920 4,520 Type2 1 3 03/03/2008 28 5.97 27.99 132,870 4,750 Type2 Average 4,640 1 4 03/31/2008 56 ~E3 ~g] [iill E;) DO 0 Type 1 Type 2 Type 3 Type 4 Type 5 fi/~ Type 6 711})l~ ~ LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (TMIKW) Page 1 of 2