Gateway BP(3.1)-LR080207
Rone Engineering
..
8908 Ambassador Row, Dallas, TX 75247
7701 W Little York, Ste 600, Houston, TX 77040
4421 Freidrich, Ste 195, Austin, TX 78744
Corporate Phone: (214) 630-9745
Client:
Transwestern Commercial Services
5001 Spring Valley
Dallas, TX 75244
Report of Reinforcing Steel Inspection
Report No.: 312423
Pr,?ject No.: 0712786
Date of Service: 02/01/2008
Report Date: 02/07/2008
Project: Gateway Business Center
Coppell, Texas
Services: Reinforcing Steel Inspection
Report of Inspection
Locations and Items Inspected:
Footing for sign statues on northwest and S'outhwest entrances on Freeport Pkwy.
Items Inspected Conforming Non Item s Inspected Conforming Non Item s Inspected: Co nfo rm Ing Non
Co nfo rm ing Conforming Co n10 rm ing
P laCing Drawings Bar Length Column Ties Pro perly
Appro ved x and Shape x Tied and Spaced NA
BarSt,e x Pro per B af P lacem ent x Stirrup Spacing NA
Bar Grade x ProperlyT,ed x Stirrup Type NA
Bars Clean x DowelBars in Place x Lapped Splices NA
Fa fm Clean x ProperBarSupporls x CamerBsrs NA
NumberofBars x ProperCover x Mechanical Splices NA
Discrepancies / Comments:
1. Remove trash from placement area.
The discrepancies noted above were corrected at the time of inspection.
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd.
(TM/KW) Page 1 of 2