Duke Lesley 1A-LR080312 Rone Engineering .. Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 310619 Project No.: 0713408 Date of Service: 01/14/2008 Report Date: 03/12/2008 Project: Point West VI Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Set No. Tested (days) (in) (in2) (Ibs) (psi) 1 1 01/21/2008 7 6.00 28.27 113,440 4,010 1 2 02/11/2008 28 6.00 28.27 153,880 5,440 1 3 02/11/2008 28 6.00 28.27 159,750 5,650 Average 5,550 1 4 03/10/2008 56 6.00 28.27 189,320 6,700 Contractor: Duke Construction, LP Concrete Supplier: Potter Concrete Plant: 1 Specification Requirements Strength: 4,000 psi @ 28 days Slump (in.): 3" - 5" Air (%): 3% - 5% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 ~~ ~QJ 5IE ~ DO D Type 1 Type 2 Type 3 Type 4 Type 5 Mix Design I.D.: 7753PW6 Placement Date: 01/14/2008 Weather Conditions: Clear Time Sampled: 03:20am Temperature - Air: 400F Truck No: 133 Air Content: 4.6% Overall Placement Location: Parking lot, paving, north side of building 6 Measured Slump (inches) 5.0 Batch time: 03:03am Concrete: 550F Ticket No: 18379 Unit Weight (pet): NA Sample Location: 10' west from northwest corner of building 6 Fracture Type Type2 Type2 Type5 Type2 Type 6 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (TM/KW) Page 1 of 19 Rone Engineering . Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 310619 Project No.: 0713408 Date of Service: 01/14/2008 Report Date: 03/12/2008 Project: Point West VI Cappell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Set No. Tested (days) (in) (in') (Ibs) (psi) 2 1 01/21/2008 7 6.00 28.27 111,950 3,960 2 2 02/11/2008 28 6.00 28.27 160,010 5,660 2 3 02/11/2008 28 6.00 28.27 149,090 5,270 Average 5,470 2 4 03/10/2008 56 6.00 28.27 187,110 6,620 Contractor: Duke Construction, LP Concrete Supplier: Potter Concrete Plant: 1 Specification Requirements Strength: 4,000 psi @ 28 days Slump (in.): 3" - 5" Air (%): 3% - 5% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 ~E:J ~~ ~ [] DO D Type 1 Type 2 Type 3 Type 4 Type 5 Mix Design I.D.: 7753PW6 Placement Date: 01/14/2008 Weather Conditions: Clear Time Sampled: 03:50am Temperature - Air: 400F Truck No: 103 Air Content: 4.3% Overall Placement Location: Parking lot, paving, north side of building 6 Measured Slump (inches) 5.0 Batch time: 03:32am Concrete: S40F Ticket No: 18379 Unit Weight (pet): NA Sample Location: 25' west from northwest corner of building 6 Fracture Type Type2 Type2 TypeS Type2 Type 6 LIMIT A nONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (TM/KW) Page 3 of 19 Rone Engineering .. Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 310619 Project No.: 0713408 Date of Service: 01/14/2008 Report Date: 03/12/2008 Project: Point West VI Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Set No. Tested (days) (in) (in2) (Ibs) (psi) 3 1 01/21/2008 7 6.00 28.27 98,810 3,490 3 2 02/11/2008 28 6.00 28.27 139,360 4,930 3 3 02/11/2008 28 6.00 28.27 133,260 4,710 Average 4,820 3 4 03/10/2008 56 6.00 28.27 164,700 5,830 Contractor: Duke Construction, LP Concrete Supplier: Potter Concrete Plant: 1 Specification Requirements Strength: 4,000 psi @ 28 days Slump (in.): 3" - 5" Air (%): 3% - 5% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 ~EJ ~~ ~ E;J DO D Type 1 Type 2 Type 3 Type 4 Type 5 Mix Design I.D.: 7753PW6 Placement Date: 01/14/2008 Weather Conditions: Clear Time Sampled: 04:48am Temperature - Air: 410F Truck No: 138 Air Content: 4.5% Overall Placement Location: Parking lot, paving, north side of building 6 Measured Slump (inches) 5.5 Batch time: 04:38am Concrete: 560F Ticket No: 18392 Unit Weight (pcf): NA Sample Location: 90' west from northwest corner of building 6 Fracture Type Type5 Type3 Type2 Type2 Type 6 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (TM/KW) Page 5 of 19 Rone Engineering . Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 310619 Project No.: 0713408 Date of Service: 01/14/2008 Report Date: 03/12/2008 Project: Point West VI Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA Contractor: Duke Construction, LP Concrete Supplier: Potter Concrete Plant: 1 Specification Requirements Strength: 4,000 psi @ 28 days Slump (in.): 3" - 5" Air (%): 3% - 5% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 Mix Design 1.0.: 7753PW6 Placement Date: 01/14/2008 Weather Conditions: Clear Time Sampled: 05:50am Temperature - Air: 410F Truck No: 135 Air Content: 4.2% Overall Placement Location: Parking lot, paving, north side of building 6 Measured Slump (inches) 5.0 Batch time: 05:32am Concrete: 570F Ticket No: 18405 Unit Weight (pcf): NA Sample Location: 180' west from northwest corner of building 6 REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Fracture Set No. Tested (days) (in) (in') (Ibs) (psi) Type 4 1 01/21/2008 7 6.00 28.27 102,810 3,640 Type2 4 2 02/11/2008 28 6.00 28.27 134,380 4,750 Type2 4 3 02/11/2008 28 6.00 28.27 140,230 4,960 Type2 Average 4,860 4 4 03/10/2008 56 5.99 28.18 158,330 5,620 Type2 ~EJ ~~ ~ t] DO 0 ~j- /,--, " Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 " .--.---".-.-.-- LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance. etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (TM/KW) Page 7 of 19 Rone Engineering . Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 310619 Project No.: 0713408 Date of Service: 01/14/2008 Report Date: 03/12/2008 Project: Point West VI Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Set No. Tested (days) (in) (in') (Ibs) (psi) 5 1 01/21/2008 7 6.00 28.27 109,850 3,890 5 2 02/11/2008 28 6.00 28.27 140,940 4,980 5 3 02/11/2008 28 6.00 28.27 129,650 4,590 Average 4,790 5 4 03/10/2008 56 6.00 28.27 145,940 5,160 Contractor: Duke Construction, LP Concrete Supplier: Potter Concrete Plant: 1 Specification Requirements Strength: 4,000 psi @ 28 days Slump (in.): 3" - 5" Air (%): 3% - 5% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 ~[j ~Q] 5IE ~ DO D Type 1 Type 2 Type 3 Type 4 Type 5 Mix Design I.D.: 7753PW6 Placement Date: 01/14/2008 Weather Conditions: Sunny Time Sampled: 06:43am Temperature - Air: 350F Truck No: 133 Air Content: 4.2% Overall Placement Location: Parking lot, paving, north side of building 6 Measured Slump (inches) 5.5 Batch time: 06:20am Concrete: 520F Ticket No: 18417 Unit Weight (pet): NA Sample Location: 210' west from northwest corner of building 6 Fracture Type Type6 Type2 Type2 Type2 Type 6 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (TMIKW) Page 9 of 19 Rone Engineering . Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 310619 Project No.: 0713408 Date of Service: 01/14/2008 Report Date: 03/12/2008 Project: Point West VI Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA Contractor: Duke Construction, LP Concrete Supplier: Potter Concrete Plant: 1 Specification Requirements Strength: 4,000 psi @ 28 days Slump (in.): 3" - 5" Air (%): 3% - 5% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 Mix Design 1.0.: 7753PW6 Placement Date: 01/14/2008 Weather Conditions: Sunny Time Sampled: 07:28am Temperature - Air: 380F Truck No: 133 Air Content: 4.8% Overall Placement Location: Parking lot, paving, north side of building 6 Measured Slump (inches) 5.5 Batch time: 06:54am Concrete: 540F Ticket No: 18425 Unit Weight (pcf): NA Sample Location: 270' west from northwest corner of building 6 REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Fracture Set No. Tested (days) (in) (in2) (Ibs) (psi) Type 6 1 01/21/2008 7 6.00 28.27 119,610 4,230 Type2 6 2 02/11/2008 28 6.00 28.27 142,030 5,020 Type2 6 3 02/11/2008 28 6.00 28.27 143,600 5,080 Type2 Average 5,050 6 4 03/10/2008 56 6.00 28.27 157,100 5,560 Type2 tJEJ ~[g BId ~ DO D Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 L1MrrATloNS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (TM/KW) Page 11 of 19 Rone Engineering . Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 310619 Project No.: 0713408 Date of Service: 01/14/2008 Report Date: 03/12/2008 Project: Point West VI Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Set No. Tested (days) (in) (in2) (Ibs) (psi) 7 1 01/21/2008 7 6.00 28.27 104,110 3,680 7 2 02/11/2008 28 5.97 27.99 135,600 4,840 7 3 02/11/2008 28 6.00 28.27 137,390 4,860 Average 4,850 7 4 03/10/2008 56 6.00 28.27 138,120 4,880 Contractor: Duke Construction, LP Concrete Supplier: Potter Concrete Plant: 1 Specification Requirements Strength: 4,000 psi @ 28 days Slump (in.): 3" - 5" Air (%): 3% - 5% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 0~ ~[g [ill] t] DO D Type 1 Type 2 Type 3 Type 4 Type 5 Mix Design I.D.: 7753PW6 Placement Date: 01/14/2008 Weather Conditions: Sunny Time Sampled: 08:35am Temperature - Air: 440F Truck No: 103 Air Content: 4.5% Overall Placement Location: Parking lot, paving, north side of building 6 Measured Slump (inches) 5.0 Batch time: 08: 11 am Concrete: 540F Ticket No: 18434 Unit Weight (pcf): NA Sample Location: 330' west from northwest corner of building 6 Fracture Type Type2 Type2 Type6 Type3 Type 6 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, lid. (TMIKW) Page 13 of 19 Rone Engineering . Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 310619 Project No.: 0713408 Date of Service: 01/14/2008 Report Date: 03/12/2008 Project: Point West VI Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples ancj bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Set No. Tested (days) (in) (in2) (Ibs) (psi) 8 1 01/21/2008 7 6.00 28.27 109,680 3,880 8 2 02/11/2008 28 6.00 28.27 140,830 4,980 8 3 02/11/2008 28 6.00 28.27 128,290 4,540 Average 4,760 8 4 03/10/2008 56 6.00 28.27 153,110 5,420 Contractor: Duke Construction, LP Concrete Supplier: Potter Concrete Plant: 1 Specification Requirements Strength: 4,000 psi @ 28 days Slump (in.): 3" - 5" Air (%): 3% - 5% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 0EJ ~~ 5IE ~ DO D Type 1 Type 2 Type 3 Type 4 Type 5 Mix Design I.D.: 7753PW6 Placement Date: 01/14/2008 Weather Conditions: Sunny Time Sampled: 09:30am Temperature - Air: 440F Truck No: 126 Air Content: 4.6% Overall Placement Location: Parking lot, paving, north side of building 6 Measured Slump (inches) 5.5 Batch time: 08:55am Concrete: 540F Ticket No: 18443 Unit Weight (pet): NA Sample Location: 420' west from northwest comer of building 6 Fracture Type Type2 Type6 Type6 Type6 Type 6 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (TM/KW) Page 15 of 19 Rone Engineering . Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 310619 Project No.: 0713408 Date of Service: 01/14/2008 Report Date: 03/12/2008 Project: Point West VI Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Set No. Tested (days) (in) (in') (Ibs) (psi) 9 1 01/21/2008 7 6.00 28.27 97,060 3,430 9 2 02/11/2008 28 6.00 28.27 121 ,430 4,290 9 3 02/11/2008 28 6.00 28.27 128,680 4,550 Average 4,420 9 4 03/10/2008 56 6.00 28.27 134,640 4,760 Contractor: Duke Construction, LP Concrete Supplier: Potter Concrete Plant: 1 Specification Requirements Strength: 4,000 psi @ 28 days Slump (in.): 3" - 5" Air (%): 3% - 5% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 0EJ ~0 rITE b] DO D Type 1 Type 2 Type 3 Type 4 Type 5 Mix Design I.D.: 7753PW6 Placement Date: 01/14/2008 Weather Conditions: Sunny Time Sampled: 10:30am Temperature - Air: 490F Truck No: 126 Air Content: 4.6% Overall Placement Location: Parking lot, paving, north side of building 6 Measured Slump (inches) 5.0 Batch time: 09:54am Concrete: 530F Ticket No: 18451 Unit Weight (pet): NA Sample Location: 460' west from northwest corner of building 6 Fracture Type Type2 Type6 Type2 Type3 Type 6 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (TM/KW) Page 17 of 19 Rone Engineering . Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 310748 Project No.: 0713408 Date of Service: 01/15/2008 Report Date: 03/12/2008 Project: Point West VI Cappel!, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Set No. Tested (days) (in) (in') (Ibs) (psi) 1 1 01/22/2008 7 5.98 28.09 76,830 2,740 1 2 02/12/2008 28 6.00 28.27 124,430 4,400 1 3 02/12/2008 28 6.00 28.27 129,020 4,560 Average 4,480 1 4 03/11/2008 56 6.00 28.27 140,600 4,970 Contractor: Duke Construction, LP Concrete Supplier: Potter Concrete Plant: 1 Specification Requirements Strength: 4,000 psi @ 28 days Slump (in.): 4" - 6" Air (%): NA Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 ~~ ~[g ~ t] DO D Type 1 Type 2 Type 3 Type 4 Type 5 PROJECT DATA Mix Design 1.0.: 7753 PW6 Placement Date: 01/15/2008 Weather Conditions: Partly cloudy Time Sampled: 10:23am Batch time: 09:59am Temperature - Air: 510F Concrete: 5rF Truck No: 133 Ticket No: 18540 Air Content: 5.5% Unit Weight (pet): NA Overall Placement Location: Southeast fire lane paving and south approach paving Measured Slump (inches) 9.5 Sample Location: 210' west, 8' south from northeast corner Fracture Type Type2 Type6 Type2 Type5 Type 6 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (CHfKW) Page 1 of 4 Rone Engineering . Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 310748 Project No.: 0713408 Date of Service: 01/15/2008 Report Date: 03/12/2008 Project: Point West VI Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Set No. Tested (days) (in) (in2) (Ibs) (psi) 2 1 01/22/2008 7 6.00 28.27 92,930 3,290 2 2 02/12/2008 28 6.00 28.27 131,150 4,640 2 3 02/12/2008 28 6.00 28.27 134,340 4,750 Average 4,690 2 4 03/11/2008 56 5.99 28.18 151 , 1 00 5,360 Contractor: Duke Construction, LP Concrete Supplier: Potter Concrete Plant: 1 Specification Requirements Strength: 4,000 psi @ 28 days Slump (in.): 4" - 6" Air (%): NA Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 [aC3 [@]g] rnJ E] DO D Type 1 Type 2 Type 3 Type 4 Type 5 PROJECT DATA Mix Design I.D.: 7753 PW6 Placement Date: 01/15/2008 Weather Conditions: Partly cloudy Time Sampled: 11 :20am Batch time: 1 0:49am Temperature - Air: 520F Concrete: 620F Truck No: 138 Ticket No: 18549 Air Content: 5.2% Unit Weight (pet): NA Overall Placement Location: Southeast fire lane paving and south approach paving Measured Slump (inches) 8.5 Sample Location: 45' east, 6' north from southeast corner Fracture Type Type6 Type6 Type6 Type6 Type 6 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (CH/KW) Page 2 of 4 Rone Engineering . Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600. Houston. TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 310748 Project No.: 0713408 Date of Service: 01/15/2008 Report Date: 03/12/2008 Project: Point West VI Coppell. Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing. cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Set No. Tested (days) (in) (in') (Ibs) (psi) 3 1 01/22/2008 7 6.00 28.27 91,610 3,240 3 2 02/12/2008 28 6.00 28.27 134,390 4,750 3 3 02/12/2008 28 6.00 28.27 141,980 5,020 Average 4,890 3 4 03/11/2008 56 6.00 28.27 156,680 5,540 Contractor: Duke Construction, LP Concrete Supplier: Potter Concrete Plant: 1 Specification Requirements Strength: 4,000 psi @ 28 days Slump (in.): 4" - 6" Air (%): NA Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 ~E3 ~~ ill] [;J DO D Type 1 Type 2 Type 3 Type 4 Type 5 PROJECT DATA Mix Design 1.0.: 7753 PW6 Placement Date: 01/15/2008 Weather Conditions: Partly cloudy Time Sampled: 12:20pm Batch time: 11: 16am Temperature - Air: 600F Concrete: 610F Truck No: 139 Ticket No: 18554 Air Content: 4.8% Unit Weight (pcf): NA Overall Placement Location: Southeast fire lane paving and south approach paving Measured Slump (inches) 7.5 Sample Location: 30' south, 10' east from northwest corner Fracture Type Type6 Type6 Type2 Type2 Type 6 LIMITATIONS: The test results presented herein were prepared based upon the specifiC samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, LId. (CH/KW) Page 3 of 4