Loading...
Duke Lesley 3C-LR080312 ~r(one Engineering ~.2', " ~ ~ ~~ ~ Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 8908 Ambassador KCW, DZtI12S, TX 752,'+7 7701 W Little Yo~k, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195: Austin, TX 78744 Corporate Phone: (2i4) 630-9745 Report of Concrete Compressive Strength Test Report No.: 310749 Project No.: 0711530 Date of Service: 01/15/2008 Report Date: 03/12/2008 Project: Point West Office I Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. Contractor: Duke Construction, LP Concrete Supplier: Potter Concrete Plant: 10 Specification Requirements Strength: 4,000 psi @ 28 days Slump (in.): 3" - 5" Air (%): 3% - 5% T est Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 PROJECT DATA Mix Design I.D.: 7752 Placement Date: 01/15/2008 Weather Conditions: Clear Time Sampled: 04:30am Temperature - Air: 340F Truck No: 117 Air Content: 4.8% Overall Placement Location: Fire lane paving - North side of building 1 Batch time: 04: 13am Concrete: 500F Ticket No: 10097 Unit Weight (pcf): NA Measured Slump (inches) 4.0 Sample Location: 30' west from northeast corner of building 1 - sample taken from truck REPORT OF TESTS Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Set No. Tested (days) (in) (in2) (Ibs) (psi) 1 1 01/22/2008 7 6.00 28.27 122,240 4,320 2 02/12/2008 28 6.00 28.27 160,700 5,680 3 02/12/2008 28 6.00 28.27 151,380 5,350 Average 5,520 4 03/11/2008 56 6.00 28.27 174,020 6,150 ~l3 ~nl ~J~~1 rnJ t] [JO D ~~ -~~ " -"" Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 Concrete Compressive Cylinder 6" x 12" Fracture Type Type2 Type5 Type3 Type2 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (KW/KG) Page 1 of 20 .- 1 ~r .... ~ #' ,," "~;; :,;;, .~ ~.. ~~ -. .. "~ '. ~~~ ';,-, - -. 33':'3 Ambz:ssador Row, DaUasl TX. 75247 7701 ;'if Uttle Yerie, 5te 500, Houston, TX 77040 4421 Fre:idrich, Ste 195J Austinl TX -;;8744 Corporate Phone: (214} 6:,0-9745 t~one Engineering Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 Report of Concrete Compressive Strength Test Report No.: 310749 Project No.: 0711530 Date of Service: 01/15/2008 Report Date: 03/12/2008 Project: Point West Office I Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. Remarks: Water added at site: 10 gallons LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (KW/KG) Page 2 of 20 t')f', 1"" d"'4 ~ ~1 g..... ~ r'1.\ ~ e r;_ "n_ g' 1! ~\;"",. il 'C':;: ","_II _ ~ It E...... II ~" ~ ;~;i'..., '< , :t,;"~ >~ ~', <:;.' "'" ~ ~ ^_ ~....' ~ '"'''.::...:: .t' , }" "" ,.... ~. !C~ .' ;.>'t' 8908 Ambassador F~OWI Dallas, T>~ 75247 7701 W Little Yori\, Ste 600, Houston, TX 77040 4421 Fre.idrich, Ste r95~ Austin, TX 73744 Corpor?te Phone: (214) 630.9745 Client: Report of Concrete Compressive Strength Test Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 Report No.: 310749 Project No.: 0711530 Date of Service: 01/15/2008 Report Date: 03/12/2008 Project: Point West Office I Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Set No. Tested (days) (in) (in2) (Ibs) (psi) 2 1 01/22/2008 7 6.00 28.27 123,430 4,370 2 2 02/12/2008 28 5.98 28.09 159,850 5,690 2 3 02/12/2008 28 6.00 28.27 165,930 5,870 Average 5,780 2 4 03/11/2008 56 6.00 28.27 177,720 6,290 Contractor: Duke Construction, LP Concrete Supplier: Potter Concrete Plant: 10 Specification Requirements Strength: 4,000 psi @ 28 days Slump (in.): 3" - 5" Air (%): 3% - 5% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1 064 ASTM C-138 ASTM C-39 ~[~ ~~ f\rN E] DO D .l.t{ .J...... Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 PROJECT DATA Mix Design 1.0.: 7752 Placement Date: 01/15/2008 Weather Conditions: Clear Time Sampled: 05:40am Temperature - Air: 350F Truck No: 109 Air Content: 5.1 % Overall Placement Location: Fire lane paving - North side of building 1 Batch time: 05:30am Concrete: 520F Ticket No: 10108 Unit Weight (pcf): NA Measured Slump (inches) 4.0 Sample Location: 20' north from northeast corner of building 1 - sample taken from truck Fracture Type Type2 Type2 Type2 Type3 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (KW/KG) Page 3 of 20 i:~(~ ,~:,t ',^ . P ~ H ~~"~ j~ ~t::~~ 8903 Arnb2ssador RO\"I, Dallas, TX 752/:.7 7'701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 787~4 Corporate Phone: (214) 630,9745 ~~~one Engineering C~ient: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 Report of Concrete Compressive Strength Test Report No.: 310749 Project No.: 0711530 Date of Service: 01/15/2008 Report Date: 03/12/2008 Project: Point West Office I Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards, Remarks: Water added at site: 5 gallons LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (KW/KG) Page 4 of 20 F~(H"'3e Engineering ..~~~;t~,~?t~~~1~ 'v ~' Ii ~: '~~~.~ '.:':-~~' ~~' ~~ ?~~' ~. Client: Duke Construction, LP 14241 Da!las Pkwy, Ste 1000 Dallas, TX 75254-2936 8908 Ambassador Row, Danas) TX 75247 7701 W Litt!e York, Ste GOO, HOllston, TX 77040 4421 Freidric/l, Ste 195, Austin, TX 73744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 310749 Project No.: 0711530 Date of Service: 01/15/2008 Report Date: 03/12/2008 Project: Point West Office I Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Set No. Tested (days) (in) (in2) (Ibs) (psi) - 3 1 01/22/2008 7 6_00 28.27 112,450 3,980 3 2 02/12/2008 28 6.00 28.27 147,460 ~ 3 3 02/12/2008 28 6.00 28.27 140,070 4,950 Average ,080 3 4 03/11/2008 56 6.00 28.27 160,540 5,680 Contractor: Duke Construction, LP Concrete Supplier: Potter Concrete Plant: 10 Specification Requirements Strength: 4,000 psi @ 28 days Slump (in.): 3" - 5" Air (%): 3% - 5% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1 064 ASTM C-138 ASTM C-39 ~tj ~[g t;J 0_._. -0.....-.. 0'--:- . ~ - -.., ~~,TN ~Ji i Type 1 Type 3 Type 4 Type 5 Type 2 PROJECT DATA Mix Design I.D.: 7752 Placement Date: 01/15/2008 Weather Conditions: Clear Time Sampled: 06:38am Temperature - Air: 390F Truck No: 140 Air Content: 4.4% Overall Placement Location: Fire lane paving - North side of building 1 Batch time: 06: 1 Oam Concrete: 540F Ticket No: 10115 Unit Weight (pet): NA Measured Slump (inches) 4.0 Sample Location: 90' east from northeast corner of building 1 - sample taken from pump Fracture Type Type6 Type6 Type6 Type6 Type 6 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (KW/KG) Page 5 of 20 o,'~~;O E:~' 9 .- nee. r; n f{'''if i 1.I'I",..ii . la ~~ '~'_.'<' !;(~1t~,,' . l.:;,?:i.~j" !'_: ::.~~~~,:t~ !~!i:~~~;~~ .. 3908 ,\mbassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Fretdrich, Ste ~S5J Austin, TX 78744 Corporate ?hor,e: (214) 630-97~5 Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 Report of Concrete Compressive Strength Test Report No.: 310749 Project No.: 0711530 Date of Service: 01/15/2008 Report Date: 03/12/2008 Project: Point West Office I Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards, Remarks: Water added at site: 10 gallons LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing, We assume no responsibility for variation in quality (composition, appearance, etc,) or any other feature of similar sUbject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, LId, (KW/KG) Page 6 of 20 f{one Engineering ~~~z~' < ~ : ~ ~^~ ~ 7 ~~ L ,/ .~ ~r,~~.,:~r'.-~~:~~:;\~.~\:~ Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 89D8 Ambassador Row, Dallas, TX "75247 7701 IN Little York, Ste 600, Houston, TX 77040 4421 Freid,kh, Ste 195, Austin, TX 78744 Corporate Phone: (214i 630-9745 Report of Concrete Compressive Strength Test Report No.: 310749 Project No.: 0711530 Date of Service: 01/15/2008 Report Date: 03/12/2008 Project: Point West Office I Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Set No. Tested (days) (in) (in') (Ibs) (psi) 4 1 01/22/2008 7 6.00 28.27 111,410 3,940 4 2 02/12/2008 28 6.00 28.27 131,050 4 3 02/12/2008 28 6.00 28.27 138,300 ~- Average , 0 4 4 03/11/2008 56 6.00 28.27 165,570 5,860 Contractor: Duke Construction, LP Concrete Supplier: Potter Concrete Plant: 10 Specification Requirements Strength: 4,000 psi @ 28 days Slump (in.): 3" - 5" Air (%): 3% - 5% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 ~L3 ~[g tJ] t] DO D Type 1 Type 2 Type 3 Type 4 Type 5 PROJECT DATA Mix Design 1.0.: 7752 Placement Date: 01/15/2008 Weather Conditions: Sunny Time Sampled: 08:21am Temperature - Air: 350F Truck No: 130 Air Content: 4.3% Overall Placement Location: Fire lane paving - North side of building 1 Batch time: 07:52am Concrete: 530F Ticket No: 10126 Unit Weight (pcf): NA Measured Slump (inches) 4.5 Sample Location: 24' east from southeast corner of building 1 - sample taken from pump Fracture Type TypeS Type2 TypeS TypeS Type 6 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (KW/KG) Page 7 of 20 t~one Engineering ',..,.-..-.c.:; -~~ ~ :.. ~'::;~...... ." '. ~.. - '. -~'.- ,; :: .J~~ 3908 Ambassador Row, Dallasl TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freid:ich, Ste 195, Austin, TX 73744 Corporate Phone: (214) 630-9745 CHent: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 Report of Concrete Compressive Strength Test Report No.: 310749 Project No.: 0711530 Date of Service: 01/15/2008 Report Date: 03/12/2008 Project: Point West Office I Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. Remarks: Water added at site: 5 gallons LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (KWIKG) Page 8 of 20 r~one Engineering -. ----,", ~ r' ,~ ~"';jJ:. ~~~. ".~~ " -- ~::. ~; -~-:~~":2 ':.' ..; ~ ~. ::>~~ .~ 0" _ , " Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 89Q3 Ambassadoi Row, Dallas, TX 75247 770'1 W Li(t:~ York, Ste 6ll0, Houston, TX 77040 4421 Fre!di-ich~ Ste 195, Austin, TX 73744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 310749 Project No.: 0711530 Date of Service: 01/15/2008 Report Date: 03/12/2008 Project: Point West Office I Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Set No. Tested (days) (in) (in2) (Ibs) (psi) 5 1 01/22/2008 7 6.00 28.27 120,700 4,270 5 2 02/12/2008 28 6.00 28.27 154,170 5 3 02/12/2008 28 6.00 28.27 153,590 Average 5 4 03/11/2008 56 6.00 28.27 162,340 Contractor: Duke Construction, LP Concrete Supplier: Potter Concrete Plant: 10 Specification Requirements Strength: 4,000 psi @ 28 days Slump (in.): 3" - 5" Air (%): 3% - 5% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 fvx'll;>(1 rrnl r-f--1 uUub E;] DO D fn~ Type 3 Type 4 Type 5 Type 1 Type 2 PROJECT DATA Mix Design I.D.: 7752 Placement Date: 01/15/2008 Weather Conditions: Sunny Time Sampled: 10:15am Temperature - Air: 500F Truck No: 117 Air Content: 4.5% Overall Placement Location: Fire lane paving - North side of building 1 Batch time: 09:53am Concrete: 580F Ticket No: 10144 Unit Weight (pct): NA Measured Slump (inches) 4.5 Sample Location: 90' south from southeast corner of building 1 (center) - sample taken from pump Fracture Type Type3 Type2 Type2 Type2 Type 6 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (KWfKG) Page 9 of 20 ~~one E:ngineering ~ <;~~,":"" I, ~~: ~t -:; . . :... , < ~ ""-. 8908 Ambassador Row, D211as, TX 75247 7701 V\l Little York: Ste 500, Houston, TX 77040 4421 Freidr!ch, Ste 195, Austill) TX 73i"44 Corporate Phone: (214) 630-9745 Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 Report of Concrete Compressive Strength Test Report No.: 310749 Project No.: 0711530 Date of Service: 01/15/2008 Report Date: 03/12/2008 Project: Point West Office I Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. Remarks: Water added at site: 15 gallons LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (KW/KG) Page 10 of 20 ~~one Engineering ~ :C:~2'_.y... :........~"-'> . "1 i..'l. ~:._ ' . ..: " Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 3903 I\mbassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 310749 Project No.: 0711530 Date of Service: 01/15/2008 Report Date: 03/12/2008 Project: Point West Office I Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. Contractor: Duke Construction, LP Concrete Supplier: Potter Concrete Plant: 10 Specification Requirements Strength: 4,000 psi @ 28 days Slump (in.): 3" - 5" Air (%): 3% - 5% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 PROJECT DATA Mix Design I.D.: 7752 Placement Date: 01/15/2008 Weather Conditions: Sunny Time Sampled: 10:41am Temperature - Air: 610F Truck No: 101 Air Content: 4.2% Overall Placement Location: Fire lane paving - North side of building 1 Batch time: 10:16am Concrete: 570F Ticket No: 10149 Unit Weight (pet): NA Measured Slump (inches) 4.5 Sample Location: 180' south from southeast corner of building 1 - sample taken from pump REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Fracture Set No. Tested (days) (in) (in') (Ibs) (psi) Type 6 1 01/22/2008 7 6.00 28.27 99,740 3,530 Type2 6 2 02/12/2008 28 6.00 28.27 122,930 4.350/ Type6 6 3 02/12/2008 28 5.99 28.18 123,880 4,400 Type6 Average 4,370 6 4 03/11/2008 56 6.00 28.27 129,230 4,570 Type2 ~,--- tJ. '7 [9Jn. [gi' [illj.'[-q E]- O' 0-- ./ /. IJ J \ -.J ". ..-. J-. I I Type 1 Type 2 Type 3 Type 4 Type 5 .rK ...... Type 6 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (KW/KG) Page 11 of 20 f-{one Engineering ~ ~~~~~7;f:':~ ~' ~- ,-'. ~' :~~. b ~ :~. ~~::' ~~~~<f~ 8908 Ambassador Row, Dallas, TX 75247 7701 W Uttle York, Ste 600, Houst0n, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 Report of Concrete Compressive Strength Test Report No.: 310749 Project No.: 0711530 Date of Service: 01/15/2008 Report Date: 03/12/2008 Project: Point West Office I Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. Remarks: Water added at site: 5 gallons LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (KW/KG) Page 12 of 20 t.">>"""1 ,.."~ ~ Ing:Uleerllng ~~i:;.t~J11 e ::: ~ .: I : - . ~~~~~~~; :;}::~~r:~i~:: :~: (~~: :~: 'V _', .~' ,~~:~ r~ ~~ Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 500, Houston, TX 77040 4421 Freidrich, Ste 195, r^,usUn, TX 78744 Corporate Phone: (214) 530-9745 Report of Concrete Compressive Strength Test Report No.: 310749 Project No.: 0711530 Date of Service: 01/15/2008 Report Date: 03/12/2008 Project: Point West Office I Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Set No. Tested (days) (in) (in') (Ibs) (psi) - 7 1 01/22/2008 7 6.00 28.27 150,260 5,310 7 2 02/12/2008 28 6.00 28.27 169,900 ~ 7 3 02/12/2008 28 6.00 28.27 177,410 6,270 Average 6,140 7 4 03/11/2008 56 6.00 28.27 188,100 6,650 Contractor: Duke Construction, LP Concrete Supplier: Potter Concrete Plant: 10 Specification Requirements Strength: 4,000 psi @ 28 days Slump (in.): 3" - 5" Air (%): 3% - 5% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 la- - [3-- , " / " . rr_--'~'-l 'Ill 1 )..;o~ .~.~-""_. Type 2 [ill] EJ DO D Type 1 Type 3 Type 4 Type 5 PROJECT DATA Mix Design I.D.: 7752 Placement Date: 01/15/2008 Weather Conditions: Sunny Time Sampled: 12:30pm Temperature - Air: 600F Truck No: 117 Air Content: 4.7% Overall Placement Location: Fire lane paving - North side of building 1 Batch time: 12:00pm Concrete: 640F Ticket No: 10162 Unit Weight (pcf): NA Measured Slump (inches) 4.0 Sample Location: 270' south from southeast corner of building 1 - sample taken from pump Fracture Type Type2 Type2 Type6 Type2 Type 6 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (KW/KG) Page 13 of 20 .;~~'~~; ~ ~~:'>~.',';f;r;":~;~ ;~~;~: ~W~~::'::~~:}~:.~~ 8908 Amb.sssadoi Rowl Dallasj TX 75247 7701 v{ Uttie Yorx, Ste SOO, Houston, TX 71"040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-974-5 ~~(lne Engineermng Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 Report of Concrete Compressive Strength Test Report No.: 310749 Project No.: 0711530 Date of Service: 01/15/2008 Report Date: 03/12/2008 Project: Point West Office I Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. Remarks: Water added at site: 5 gallons LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition. appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (KW/KG) Page 14 of 20 ."",...._-~ - ~_ I&. ___1'1 f{one t:nglneer~ng " '-':-"'(' .,'''-' , " .....;~~~,,'t: '" -.. ,. ~ ,.,~ ~ ~ ~ -; ".<<< -, ' ~:;.--' j''"''M . }-r ~ ::.' -<"~.Jit Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 8903 Ambassador Row, Callas, TX ,'52!,7 7701 W Utti" York, Ste 600, Houston, TX 770LO 4421 Freidrich, Ste 195, !~ustil1, TX 78744 Corporate Phone: (214) 630,9745 Report of Concrete Compressive Strength Test Report No.: 310749 Project No.: 0711530 Date of Service: 01/15/2008 Report Date: 03/12/2008 Project: Point West Office I Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Set No. Tested (days) (in) (in2) (Ibs) (psi) 8 1 01/22/2008 7 6.00 28.27 127,460 4,510 8 2 02/12/2008 28 6.00 28.27 151,130 5,350 8 3 02/12/2008 28 6.00 28.27 165,530 5,850 Average 5,600 8 4 03/11/2008 56 6.00 28.27 179,700 6,360 Contractor: Duke Construction, LP Concrete Supplier: Potter Concrete Plant: 10 Specification Requirements Strength: 4,000 psi @ 28 days Slump (in.): 3" - 5" Air (%): 3% - 5% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 r8JL3 ~cg till] [;J DO D Type 1 Type 3 Type 4 Type 5 Type 2 PROJECT DATA Mix Design 1.0.: 7752 Placement Date: 01/15/2008 Weather Conditions: Sunny Time Sampled: 01 :30pm Temperature - Air: 620F Truck No: 109 Air Content: 4.3% Overall Placement Location: Fire lane paving - North side of building 1 Batch time: 01 :08pm Concrete: 580F Ticket No: 10173 Unit Weight (pcf): NA Measured Slump (inches) 4.5 Sample Location: 360' south from southeast corner of building 1 - sample taken from pump Fracture Type Type6 Type5 Type6 Type6 Type 6 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (KW/KG) Page 15 of 20 ~...~ _~ ~ "~~'r "" '"'.- r+...~~'" . ,~" ".' .. ~ >, '-~ "'A'~",J.:~ " ..,--" I<. _ .> ~~. l";.. 8903 Arnb2SSc.dor Row, Dallas, TX 75247 7701 'N Uiti" York, Sle 600, Houston, TX 77040 44.21 FrE-!Grich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 F~one Engineering Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 Report of Concrete Compressive Strength Test Report No.: 310749 Project No.: 0711530 Date of Service: 01/15/2008 Report Date: 03/12/2008 Project: Point West Office I Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. Remarks: Water added at site: 5 gallons LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (KW/KG) Page 16 of 20 ~~'()rle Engineerarlg , ~:"('~:~;:: ;.~-~~~,: J<,~~L < r. ~.. ~~' <f ......; 1<"' ,~.... ,-:;,. Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 8908 AmbdSS2dor Rowl DaU2S: l)~ 7r;2/~7 7701 \N Liitie Yor~:, Ste 600, Houston: TX 7':),~.O 4421 Freidrich, Ste 19G, A:..:stin, TX 7~j' /4 Corporate Phon~: (214) 630.97.:'5 Report of Concrete Compressive Strength Test Report No.: 310749 Project No.: 0711530 Date of Service: 01/15/2008 Report Date: 03/12/2008 Project: Point West Office I Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. Contractor: Duke Construction, LP Concrete Supplier: Potter Concrete Plant: 10 Specification Requirements Strength: 4,000 psi @ 28 days Slump (in.): 3" - 5" Air (%): 3% - 5% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 PROJECT DATA Mix Design 1.0.: 7752 Placement Date: 01/15/2008 Weather Conditions: Sunny Time Sampled: 02:10pm Temperature - Air: 650F Truck No: 109 Air Content: 4.6% Overall Placement Location: Fire lane paving - North side of building 1 Batch time: 01:41pm Concrete: 610F Ticket No: 10179 Unit Weight (pcf): NA Measured Slump (inches) 4.5 Sample Location: 392' south from southeast corner of building 1 (center) - sample taken from truck REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Fracture Set No. Tested (days) (in) (in2) (Ibs) (psi) Type 9 1 01/22/2008 7 6.00 28.27 88,410 3,130 Type6 9 2 02/12/2008 28 6.00 28.27 127,330 4,500 Type6 9 3 02/12/2008 28 6.00 28.27 120,950 4,280 Type6 Average 4,390 9 4 03/11/2008 56 5.99 28.18 140,270 4,980 Type2 [2jEJ ~cg [[U t] DO D Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (KW/KG) Page 17 of 20 ~~~::;~~':~"> " ~ ....~-" >~...- , ~ + ~ ~,.. ,~ 1- :c ' 8908 ,l\.mbassador Row, DaHas, TX 75247 7701 W Little York, Ste 500, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 73744 Corporate Phone: (214) 630-9745 Rone Engineering Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 Report of Concrete Compressive Strength Test Report No.: 310749 Project No.: 0711530 Date of Service: 01/15/2008 Report Date: 03/12/2008 Project: Point West Office ( Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. Remarks: Water added at site: 15 gallons LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (KW/KG) Page 18 of 20 lFtone Engineering ~~~. '~:~' ~~~~.~~:~ _~ ~ _ r ,~. ~;' .~, '_-~ , ';0. ~ 1"~, '" . ~ ~ .. ~-:;.~';^ CHent: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 8908 Ambassador Row, D3i1as, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630.9745 Report of Concrete Compressive Strength Test Report No.: 310749 Project No.: 0711530 Date of Service: 01/15/2008 Report Date: 03/12/2008 Project: Point West Office I Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. Contractor: Duke Construction, LP Concrete Supplier: Potter Concrete Plant: 10 Specification Requirements Strength: 4,000 psi @ 28 days Slump (in.): 3" - 5" Air (%): 3% - 5% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 PROJECT DATA Mix Design 1.0.: 7752 Placement Date: 01/15/2008 Weather Conditions: Sunny Time Sampled: 03:10pm Temperature - Air: 650F Truck No: 117 Air Content: 4.7% Overall Placement Location: Fire lane paving - North side of building 1 Batch time: 01 :59pm Concrete: 630F Ticket No: 18569 Unit Weight (pcf): NA Measured Slump (inches) 4.0 Sample Location: 482' south from southeast corner of building 1 - sample taken from truck REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Fracture Set No. Tested (days) (in) (in2) (Ibs) (psi) Type 10 1 01/22/2008 7 6.00 28.27 84,790 3,000 Type6 10 2 02/12/2008 28 6.00 28.27 125,940 4,450 Type2 10 3 02/12/2008 28 6.00 28.27 121,670 4,300 Type6 Average 4,380 10 4 03/11/2008 56 6.00 28.27 133,020 4,700 Type5 [8Jtj III cg D1] [;J DO D Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (KW/KG) Page 19 of 20 ~:~one Engineering ~ l :r.. ..- ~ ',,"' _~l;f~. .:"" :',f.. ~ ~ ~,'\~ , , .. . 'l< ~.. '" " "~ / ..,,<\;. . '"'\- ):, .' ~':E" 8908 Ambassador Row: Dallas, TX 752-17 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Cfient: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 Report of Concrete Compressive Strength Test Report No.: 310749 Project No.: 0711530 Date of Service: 01/15/2008 Report Date: 03/12/2008 Project: Point West Office I Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. Remarks: Water added at site: 10 gallons Technician: David Best Started: 03:30am Report Distribution: Orig: Duke Construction, LP (Dallas, TX) Attn: Mr. Paul Byrne (1-ec copy) 1-cc Potter Concrete AUn: Mr Ryan Skelly 1-ec Duke Construction, LP AUn: Mr. Jason Sulzener 1-cc City of Coppell AUn: Mr. Lee Stone 1-cc City of Coppell AUn: Mr. Larry Davis Finished: 04:30pm Rone Engineering P-~~ K. Scott Watson, AET Project Manager LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (KW/KG) Page 20 of 20