Loading...
ST9905-LR080328 ~, ECS Texas. LLP ECL 4950 Keller Springs Road. SUite 480 ~ AddISO. n, TX 75001 (972) 392-3222 LLP (FAXl392-11102 CONCRETE, GROUT, AND MORTAR TESTS LETTER OF TRANSMITTAL Tl!XAS TO: City ofCoppell P.O. Box 9478 DATE: 03/28/2008 RE: Bethel Road - Coppell Coppell,TX 75019 PERMIT #: ATTN: Ms. Carol Dye JOB NO.: 005061 LOCA nON: Bethel Road, Coppell, TX We are enclosing: X Attached Materials Engineering Division Concrete Reports: 122,123,124 x X For Your Use X As Requested CC: TISEO Paving - Robert Caudill City of Coppell - Rick O'Dell By: . . . . if,,-~'2~~;~i!A M~rk. Riz~R~lh.,tE;-P/1"1i 28 2~008 PnnclpaF:,~mee't'.!-) -, 'i, '/', 'Il,'!'.(,~s'" ECS Texas, LLP 4950 Keller Spnngs Road, SUIte 480 AddIson, TX 7500 I (972) 392-3222 (FAX) 3'12-0102 Concrete Cylinders Strength Report ~UP ~~ Project: Location: Bethel Road - Coppell Bethel Road, Coppell, TX Project: 5061 Cast Date: Design Strength: Report No.: Set Designation: A 02/29/2008 4000 psi 122 Owner: City of Coppell - Carol Dye Client: City of Coppell - Kenneth M. Griffin, Arch.: Gen. Contr.: Struc. Eng.: Cone. Contr.: Placement Location: Stamped concrete for Entech, 1000 ft East of Royal Lane on Bethel Rd Concrete Supplier: Southern Star Mix Designation: 9363 Added Water: Truck No: 931 Mix Strength: 4000 pSI Time Added: Ticket No: 1214324 Batch Time: 09:45AM Unit Wt.: FIELD TEST DATA: Tested by: Jonathan E. Steiner Temperature - Air: 700 F Time Sampled:1 0:20AM Concrete: 740 F Slump: 4.00 in. Air Content:3.20 % (P) Sample Test Test Type DIameter Area Breaking Compr. Brk Break Review No Date Age Cure In. In.2 Load,lbs Str.,psi Typ by by 39365 03/07/2008 7 Lab 4.00 12.56 51936 4130 RJL 39366 03/28/2008 28 Lab 4.00 12.56 75680 6020 3 RJL 39367 03/28/2008 28 Lab 4.00 12.56 71328 5680 3 RJL 39368 04/25/2008 56 Lab 4.00 12.56 Sampling In accordance with (law) ASTM C172, except that samples may have been taken from the beginning of the load after a minimum discharge of approximately one cubic yard, Cylinder molding and laboratory curing iaw ASTM C31 compressive strength test and break type law ASTM C39, slump iaw C143, air content iaw ASTM C173 (V) or C231 (P), temperature iaw ASTM C1064, and unit weight iaw ASTM C138. Cylinders are tested using unbonded caps law ASTM C1231 or are capped using sulphur mortar iaw C617. Break Types are classified as: Type 1. 2, 3, 4, 5 or 6 iaw C39-04a FIELD CURING CONDITIONS: Curing Box X No Curing Box Remarks: Insulated Heated Cooled X Caps Ice Other Final Review By: ---~------------- ELB1 Print Date: 03/28/2008 ECS Texas, LLP 4950 Keller Spnngs Road, SUite 480 Addison, TX 75001 1972) 392-3222 (FAX) 392-0102 Concrete Cylinders Strength Report , ~ ~~ Project: Location: Bethel Road - Coppell Bethel Road, Coppell, TX Project: 5061 Cast Date: Design Strength: Report No.: Set Designation: B 02/29/2008 3600 psi 123 Owner: City of Coppell - Carol Dye Arch.: Struc. Eng.: Client: City of Coppell - Kenneth M. Griffin, Gen. Contr.: Conc. Contr.: Placement Location: Box culvert walls, sampled at Sta. 44+50 Concrete Supplier: LMC Mix Designation: 1701 Added Water: 5 Gals. Truck No: 7060 Mix Strength: 3600 pSI Time Added: n:_ Ticket No: Batch Time: Unit Wt.: 7189201 01:36PM FIELD TEST DATA: Tested by:Jonathan E. Steiner Temperature - Air: 760 F Time Sampled:02: 15PM Concrete: 790 F Slump:5.00 in. Air Content:6.00 % (P) Sample Test Test Type Diameter Area Breaking Compr. Brk Break Review No Date Age Cure In. In.2 Load,lbs Str.,psi Typ by by ~9377 03/07/2008 7 Lab 4.00 12.56 49408 3930 RJL ~9378 03/28/2008 28 Lab 4.00 12.56 65888 5240 4 RJL 39379 03/28/2008 28 Lab 4,00 11,56 64384 5120 4 RJL 39380 04/25/2008 56 Lab 4.00 12.56 Sampling In accordance with (law) ASTM C172. except that samples may have been taken from the beginning of the load after a minimum discharge of approximately one cubic yard. Cylinder molding and laboratory curing law ASTM C31, compressive strength test and break type law ASTM C39. slump iaw C143, air content iaw ASTM C173 (V) or C231 (P), temperature iaw ASTM C1064, and unit weight iaw ASTM C138 Cylinders are tested using unbonded caps iaw ASTM C1231 or are capped using sulphur mortar iaw C617. Break Types are classified as: Type 1,2,3,4.5 or 6 law C39-04a FIELD CURING CONDITIONS: Curing Box X No Curing Box Remarks: Insulated Heated Cooled X Caps Ice Other Final Review By: ELBI Print Date: 03/28/2008 , ~ ECS Texas, LLP 49)0 Keller Sprlllgs Road, SLlIte 480 Addison, TX 7)001 1972) 392-3222 (FAX) 392-0102 Concrete Cylinders Strength Report -~ Project: Location: Bethel Road - Coppell Bethel Road, Coppell, TX Project: 5061 Cast Date: Design Strength: Report No.: Set Designation: C 02/29/2008 4000 psi 124 Owner: City of Coppell - Carol Dye Arch.: Struc. Eng.: Placement Location: Inlet top at East entrance to Cici's. Client: City ofCoppell- Kenneth M. Griffin, Gen. Contr.: Cone. Contr.: Concrete Supplier: Southern Star Mix Designation: 9363 Added Water: Truck No: 1020 Mix Strength: 4000 pSI Time Added: Ticket No: Batch Time: Unit Wt.: 1214859 01 :52PM FIELD TEST DATA: Tested by:.lonathan E. Steiner Temperature - Air: 780 F Time Sampled:03 :OOPM Concrete: 800 F Slump:3.50 in. Air Content:l.30 % (P) Sample Test Test Type Diameter Area Breaking Compr. Brk Break Review No Date Age Cure In. In.2 Load,lbs Str.,psi Typ by by 39381 03/07/2008 7 Lab 4.00 12.56 44288 3520 RJL 39382 03/28/2008 28 Lab 4.00 12.56 60160 4790 3 RJL 39383 03/28/2008 28 Lab 4.00 12.56 39384 03/28/2008 28 Lab 4.00 12.56 60320 4800 3 RJL Sampling in accordance with (law) ASTM C172, except that samples may have been taken from the beginning of the load after a minimum discharge of approximately one cubic yard. Cylinder molding and laboratory curing iaw ASTM C31 compressive strength test and break type iaw ASTM C39, slump iaw C143, air content iaw ASTM C173 (V) or C231 (P), temperature iaw ASTM C1064, and unit weight iaw ASTM C138. Cylinders are tested using un bonded caps iaw ASTM C1231 or are capped using sulphur mortar law C617. Break Types are classified as: Type 1, 2, 3, 4, 5, or 6 iaw C39-04a FIELD CURING CONDITIONS: Curing Box X No Curing Box Remarks: Insulated Heated Cooled X Caps Ice Other Final Review By: ELB1 Print Date: 03/28/2008 ~ ECS Texas, L LP 49S0 Keller Springs Road, SUite 480 Addison, TX 75001 (972) 392-3222 (FAX) 392-0 I 02 CONCRETE, GROUT, AND MORTAR TESTS LETTER OF TRANSMITTAL "'mXA$ TO: City of Coppell P.O. Box 9478 DATE: 03/28/2008 RE: Bethel Road - Coppell Coppell, TX 75019 PERMIT #: ATTN: Ms. Carol Dye JOB NO.: 005061 LOCA TION: Bethel Road, Coppell, TX We are enclosing: X Attached Materials Engineering Division Concrete Reports: 120 X X For Your Use X As Requested CC: TISEO Paving - Robert Caudill City of Coppell - Rick O'Dell &~~..... Ene L. Branch, C.E.T. Project Manager By: Mark R. Zortman, P.E. Principal Engineer ECS Texas, LLP 4950 Keller Springs Road, SUIte 480 Addison, TX 75001 (972) 392- 3222 (FAX) 392-0]02 Concrete Cylinders Strength Report ~ ~~ Project: Location: Bethel Road - Coppell Bethel Road, Coppell, TX Project: 5061 Cast Date: Design Strength: Report No.: Set Designation: A 02/28/2008 3600 psi 120 Owner: City of Coppell - Carol Dye Arch.: Struc. Eng.: Client: City of Coppell - Kenneth M. Griffin, Gen. Contr.: Conc. Contr.: Placement Location: Box culvert walls for South side of Bethel Rd. sampled at approximatly Station 55+50, in the middle South wall Concrete Supplier: LMC Mix Designation: 170 I Added Water: Truck No: 7025 Mix Strength: 3600 pSI Time Added: Ticket No: Batch Time: Unit Wt.: 7189145 03:00PM FIELD TEST DATA: Tested by: David L. Hunt Temperature - Air: 680 F Time Sampled:03:38PM Concrete: 650 F Slump:5.00 in. Air Content:6.00 % (P) Sample Test Test Type Diameter Area Breaking Compr. Brk Break Review No Date Age Cure In. In.2 Load,lbs Str.,psi Typ by by 39262 03/13/2008 14 Lab 4.00 12.56 53824 4280 2 ELBI 39263 03/27/2008 28 Lab 4.00 12.56 63744 5070 3 ELBI 19264 03/27/2008 28 Lab 4.00 12.56 64384 5120 3 ELBI 39265 04/24/2008 56 Lab 4.00 12.56 Sampling In accordance with (law) ASTM C172, except that samples may have been taken from the beginning of the load after a minimum discharge of approximately one cubic yard. Cylinder molding and laboratory curing iaw ASTM C31, compressive strength test and break type iaw ASTM C39, slump iaw C143, air content iaw ASTM C173 (V) or C231 (Pl. temperature law ASTM C1064, and unit weight law ASTM C138, Cylinders are tested using unbonded caps iaw ASTM C1231 or are capped using sulphur mortar iaw C617 Break Types are classified as: Type 1,2 3.4,5. or 6 law C39-04a FIELD CURING CONDITIONS: Curing Box X No Curing Box Remarks: Insulated Heated Cooled X Caps Ice Other Final Review By: ELBl Print Date: 03/28/2008