Duke Lesley 1A-LR080328 Rone Engineering " Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 312210 Project No.: 0713408 Date of Service: 01/31/2008 Report Date: 03/28/2008 Project: Point West VI Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations. perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA Contractor: Duke Construction, LP Concrete Supplier: Potter Concrete Plant: On site Specification Requirements Strength: 4,000 psi @ 28 days Slump (in.): 4" - 6" Air (%): 4% - 6% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 Mix Design I.D.: 7753 Placement Date: 01/31/2008 Weather Conditions: Cloudy Time Sampled: 03:15am Temperature - Air: 480F Truck No: 133 Air Content: 6.0% Overall Placement Location: (Paving) Load dock parking spaces on side side Measured Slump (inches) 6.0 Batch time: 03:08am Concrete: 530F Ticket No: NA Unit Weight (pcf): NA Sample Location: Grid line U21.1. 75' south REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Fracture Set No. Tested (days) (in) (in') (Ibs) (psi) Type 1 1 02/07/2008 7 6.00 28.27 106,820 3,780 Type5 1 2 02/28/2008 28 6.00 28.27 152,960 5,410 Type2 1 3 02/28/2008 28 6.00 28.27 150,870 5,340 Type2 Average 5,370 1 4 03/27/2008 56 6.00 28.27 160,920 5,690 Type5 0E:J ~~ ~ E] DO D '" Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition. appearance. etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (KW/KW) Page 1 of 9 Rone Engineering .. Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 312210 Project No.: 0713408 Date of Service: 01/31/2008 Report Date: 03/28/2008 Project: Point West VI Coppel!, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA Contractor: Duke Construction, LP Concrete Supplier: Potter Concrete Plant: On site Specification Requirements Strength: 4,000 psi @ 28 days Slump (in.): 4" - 6" Air (%): 4% - 6% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 Mix Design 1.0.: 7753 Placement Date: 01/31/2008 Weather Conditions: Cloudy Time Sampled: 04:40pm Temperature - Air: 400F Truck No: 103 Air Content: 5.9% Overall Placement Location: (Paving) Load dock parking spaces on side side Measured Slump (inches) 6.0 Batch time: Concrete: 520F Ticket No: NA Unit Weight (pcf): NA Sample Location: Grid line U19.9, 35' south REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Fracture Set No. Tested (days) (in) (in') (Ibs) (psi) Type 2 1 02/07/2008 7 5.99 28.18 116,120 4,120 Type5 2 2 02/28/2008 28 6.00 28.27 176,040 6,230 Type2 2 3 02/28/2008 28 6.01 28.37 169,790 5,990 Type5 Average 6,110 2 4 03/27/2008 56 6.00 28.27 196,190 6,940 Type2 ~tJ [l]Q] flE ~ DO D Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (KW/KW) Page 2 of 9 Rone Engineering . Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 312210 Project No.: 0713408 Date of Service: 01/31/2008 Report Date: 03/28/2008 Project: Point West VI Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA Contractor: Duke Construction, LP Concrete Supplier: Potter Concrete Plant: On site Specification Requirements Strength: 4,000 psi @ 28 days Slump (in.): 4" - 6" Air (%): 4% - 6% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1 064 ASTM C-138 ASTM C-39 Mix Design I.D.: 7753 Placement Date: 01/31/2008 Weather Conditions: Cloudy Time Sampled: 05:45am Temperature - Air: 430F Truck No: 103 Air Content: 5.5% Overall Placement Location: (Paving) Load dock parking spaces on side side Measured Slump (inches) 5.0 Batch time: Concrete: 560F Ticket No: NA Unit Weight (pcf): NA Sample Location: Grid line U18, 90' south REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Fracture Set No. Tested (days) (in) (in') (Ibs) (psi) Type 3 1 02/07/2008 7 6.00 28.27 130,980 4,630 Type5 3 2 02/28/2008 28 6.00 28.27 183,230 6,480 Type2 3 3 02/28/2008 28 6.00 28.27 184,940 6,540 Type2 Average 6,510 3 4 03/27/2008 56 6.00 28.27 197,920 7,000 Type2 0E:J ~~ ITa bJ DO D Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 LIMIT A TrONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our lelters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services. Ltd. (KW/KW) Page 3 of 9 Rone Engineering .. Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 312210 Project No.: 0713408 Date of Service: 01/31/2008 Report Date: 03/28/2008 Project: Point West VI Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA Contractor: Duke Construction, LP Concrete Supplier: Potter Concrete Plant: On site Specification Requirements Strength: 4,000 psi @ 28 days Slump (in.): 4" - 6" Air (%): 4% - 6% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 Mix Design I.D.: 7753 Placement Date: 01/31/2008 Weather Conditions: Cloudy Time Sampled: 07:01am Temperature - Air: 420F Truck No: 139 Air Content: 5.5% Overall Placement Location: (Paving) Load dock parking spaces on side side Measured Slump (inches) 5.0 Batch time: Concrete: 510F Ticket No: NA Unit Weight (pcf): NA Sample Location: Grid line U17.1, 60' south REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Fracture Set No. Tested (days) (in) (in') (Ibs) (psi) Type 4 1 02/07/2008 7 6.00 28.27 155,350 5,490 Type5 4 2 02/28/2008 28 6.00 28.27 186,710 6,600 Type2 4 3 02/28/2008 28 6.00 28.27 196,780 6,960 Type2 Average 6,780 4 4 03/27/2008 56 6.00 28.27 199,010 7,040 Type3 ~E3 ~~ ~ ~ DO D Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (KWIKW) Page 4 of 9 Rone Engineering " Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630.9745 Report of Concrete Compressive Strength Test Report No.: 312210 Project No.: 0713408 Date of Service: 01/31/2008 Report Date: 03/28/2008 Project: Point West VI Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Set No. Tested (days) (in) (in') (Ibs) (psi) 5 1 02/07/2008 7 6.00 28.27 160,880 5,690 5 2 02/28/2008 28 6.00 28.27 187,270 6,620 5 3 02/28/2008 28 5.99 28.18 192,220 6,820 Average 6,720 5 4 03/27/2008 56 6.00 28.27 197,930 7,000 Contractor: Duke Construction, LP Concrete Supplier: Potter Concrete Plant: On site Specification Requirements Strength: 4,000 psi @ 28 days Slump (in.): 4" - 6" Air (%): 4% - 6% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 ~ESJ [9]~ Q] tJ DO D Type 1 Type 2 Type 3 Type 4 Type 5 Mix Design I.D.: 7753 Placement Date: 01/31/2008 Weather Conditions: Cloudy Time Sampled: 08:30am Temperature - Air: 450F Truck No: 126 Air Content: 5.8% Overall Placement Location: (Paving) Load dock parking spaces on side side Measured Slump (inches) 5.5 Batch time: Concrete: 530F Ticket No: NA Unit Weight (pet): NA Sample Location: Grid line U15.9, 10' south Fracture Type Type5 Type5 Type5 Type6 Type 6 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, ltd. (KW/KW) Page 6 of 9 Rone Engineering .. Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 312210 Project No.: 0713408 Date of Service: 01/31/2008 Report Date: 03/28/2008 Project: Point West VI Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Set No. Tested (days) (in) (in') (Ibs) (psi) 6 1 02/07/2008 7 6.00 28.27 154,900 5,480 6 2 02/28/2008 28 6.00 28.27 199,930 7,070 6 3 02/28/2008 28 6.00 28.27 200,150 7,080 Average 7,070 6 4 03/27/2008 56 6.00 28.27 201,870 7,140 Contractor: Duke Construction, LP Concrete Supplier: Potter Concrete Plant: On site Specification Requirements Strength: 4,000 psi @ 28 days Slump (in.): 4" - 6" Air (%): 4% - 6% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 ~[J ~~ 5IE ~ DO D Type 1 Type 2 Type 3 Type 4 Type 5 PROJECT DATA Mix Design 1.0.: 7753 Placement Date: 01/31/2008 Weather Conditions: Sunny, windy Time Sampled: 09:30am Batch time: Temperature - Air: 490F Concrete: 540F Truck No: 133 Ticket No: NA Air Content: 5.5% Unit Weight (pet): NA Overall Placement Location: (Paving) Load dock parking spaces on side side Measured Slump (inches) 5.0 Sample Location: Grid line U13.8, 55' south Fracture Type Type6 Type2 Type2 Type2 Type 6 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance. etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (KW/t<W) Page 7 of 9 Rone Engineering ~ . Client: Duke Construction, LP 14241 Dallas Pkwy, Ste 1000 Dallas, TX 75254-2936 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 312210 Project No.: 0713408 Date of Service: 01/31/2008 Report Date: 03/28/2008 Project: Point West VI Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. Contractor: Duke Construction, LP Concrete Supplier: Potter Concrete Plant: On site Specification Requirements Strength: 4,000 psi @ 28 days Slump (in.): 4" - 6" Air (%): 4% - 6% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 PROJECT DATA Mix Design I.D.: 7753 Placement Date: 01/31/2008 Weather Conditions: Sunny, windy Time Sampled: 11:15am Batch time: Temperature - Air: 500F Concrete: 530F Truck No: 126 Ticket No: NA Air Content: 5.0% Unit Weight (pet): NA Overall Placement Location: (Paving) Load dock parking spaces on side side Measured Slump (inches) 5.0 Sample Location: Grid line U12.8, 60' south REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Fracture Set No. Tested (days) (in) (in') (Ibs) (psi) Type 7 1 02/07/2008 7 6.00 28.27 107,390 3,800 Type2 7 2 02/28/2008 28 6.00 28.27 145,880 5,160 Type5 7 3 02/28/2008 28 6.00 28.27 142,060 5,020 Type3 Average 5,090 7 4 03/27/2008 56 6.00 28.27 154,990 5,480 Type6 ~E:j [gJ0 rnJ t;J DO D Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (KW/KW) Page 8 of 9