Grapevine Springs CC-CS080506 TRENCH SAFETY PLAN UTILITY LINES COPPEll SERVICE CENTER (IN AND AROUND BETHEL RD & PARK RD) COPPEll, TEXAS FOR COPPEll SERVICE CENTER Note: Soil information indicates that a stiff clay (Type liB" soil) will be found on the project site. The following applies: H = 3/4 in stiff clay (Type liB" soil or better). H = 1 or greater in Type "C" soil ~ ~J&1r' ..... " --~~ F)': '\ .....JC.t-........ ..i'i':', ;'0;;" *"-''!'J,f , ... " '. ~ ;*: ....l, ,,*.. '. """J I . ...... ,... . . :,. .. ... .. ... .. ... .. ... . .. : .. . J ~ RICHARD HALDER ~ ,... .. ... .. ... .. ... ... .. ....... .. .~ 'l~", 76134 ..~J . o'.-9~ t)."~'" ("~. ~.~. 'STE.t<'!'..;#. / , "~lfJL I Trench Safety Plan for: N CENTRAL PLUMBING Pg: 101:5 Utility lines Job No: 4694 lOchard Halder P .E. Coppell SelVice Center Date :06 May 2008 Trench Safety Engineering 833 Rachelte Coppelt,Texas Scale : As shown Red Oak. Texas 15154 Design: R.H. 1-800-900-9775 GENERAL NOTES 1 For all excavations of trenches, which will exceed a depth of five feet, the Contractors trench safety procedures shall meet the current standards established by OSHA on excavations, trenching, shoring, and confined spaces, all of which are incorporated herein by reference. 2. If details shown are not feasible due to unanticipated conditions, the Contractor shall notify the Trench Safety Engineer for re-evaluation. 3 These drawings assume all excavated areas remain free of water seepage or intrusion. Excavations shall be inspected after every storm or other hazard-increasing occurrence to assure the continued safety of the trench. The Contractor shall seek guidance from the Trench Safety Engineer where needed. 4. When installing a support system, shoring will be applied by starting at the top of the trench excavation and working downward. All cross beams, trench jacks, etc., will be placed in a true horizontal position. Support system removal shall begin at the bottom and proceed upward, performed from outside the trench. 5. Materials used for sheeting, sheet piling, bracing, shoring, etc., shall be in good serviceable condition. Timbers used shall be sound and free from large or loose knots and shall be designed and installed so to be effective to the bottom of the excavation. 6. Alternate design for use of steeper slopes of the use of supporting systems, i.e., piling, cribbing, shoring, etc., may be submitted by the Contractor for evaluation by the Trench Safety Engineer. 7. Slopes shown shall be the maximum unless changed by the Trench Safety Engineer due to changing soil conditions. Slopes shown are for a short-term period. If excavations are open for more than 24 hours, the Trench Safety Engineer shall be contacted for evaluation. 8. Cohesive soils are classified by their unconfined compressive strength, as follows: (psf = pounds per square foot; tons/sq ft = tons per square foot) Type "An... more than 3,000 psf (1.5 tons/sq ft) Type "B"... more than 1,000 psf (0.5 tons/sq ft) and less than 3,000 psf (1.5 tons/sq ft) Type "C". ..less than 1 ,000 psf (0.5 tons/sq ft) that is not flowing or submerged. Trench Safety Plan for: N CENTRAL PLUMBING Pg:20f:5 Utility lines Job No: 4694 Richard Halder P.E. Coppell Service Center Date :06 May 2008 Trench Safety Engineering 833 Rachelle Coppell, Texas Scale : As shown Red Oak. Texas 15154 Design: R.H. 1.800.900.9175 Note: Either benched or sloped is acceptable '.',".', ""j- . . . .. .. .. .. .. > > ,4' max. ~ '\. ~ " 1 0' max. ~ '" , , , '" . . - . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . H As Required lYPICAl OPEN CUT CROSS SECTION N.T.S. Trench Safety Plan Utitity li n es Coppell Service Center Coppell, Texas for: N CENTRAL PLUMBING Job No: 4694 chard a der Date :06 May 2008 Trench Safety Engineering 833 Rachelle Scale : As shown Red Oak Texas 75154 Design: R.H. 1-800-900-9775 Spaced 6' to 8' o.c. in unweathered limestone. Spaced .4' o.c. in stiff clay (Type "B" soil) and weathered limestone. Spaced 4' o.c., in dry Type "e" soli sheeted with 3/...., 14-ply Finland Birch, or 1-111)" CDX plywood, or approved equal. 'Standard' hydraulic shoring ~ I 4' min. I . , 6' max. 2'rn~{ :::::>:: :':::::::::::::::::::::::: As per manufacturer's .. . :-: . : ::. : .: :: :: :-: :: .: data and limitations <>1 I. As Required ,I The aluminum hydraulic shoring listed below are just three examples of trade names of 'standard' hydraulic shoring which are acceptable. The examples are with a width maximun ofSS" Speed Shore Hydraulic Shores. model No. V-1-55 or V-5-55, or V-3.5-55. or equal. Shores may be stacked. GME Vertical Shores, model No. HVS-l -3455 or HVS-5-3..55, or HVS-J.5-J455, or equal. Shores may be stacked, EFFICIENCY PRODUCTION, models No. lX3455-5 or 5)(3455-5, or 3.5X3455.5 or e ual. Shores ma be stacked. Also available are Speed Shore "Heavy Duty' shores, which rails run in the 8', 12', and 16' range. ALTERNATE HYDRAULIC SHORING CROSS SECTION N.T.S. Trench Safe Plan Utility li n es Coppelt Setvice Center Coppell, Texas 10' max . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . , . . . . . . . . . . . . . . . . . . . - . . . . . . . . . . , . , , , . . . . . . . . . . . . . . . . . - . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . , . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ,. I.'.....,..,..............,',.......,.,...,.... .. ....4' mox. . . . .{> Il As Required ,I CROSS-SECTION N.T.S. Trench Box/shield side wall capacity shall be equal or greater than 420 pst for Type "B" soil and equal or greater than 600 psffor Type "C" soil. If there are any changes in soil conditions, the Trench Safety Engineer shall be contacted for evaluation. Any manufactured/rated trench shield system, such as Manhole Rings, Modular Shields, Panel Shields, etc. are included in this catagory. Trench box capacity, given above, refers to sidewall capacity of bottom box, in Type "B" soil, when boxes are stacked. If contractor requires "closed ends" for trench box, one accaptable method is by placing 314", or greater (or equal) substitute) steel plate (width size may vary) against spreaders of trench box. Other methods may be used with approval of Trench Safety Engineer. Al TERNATE TRENCH BOX CROSS SECTION N.T.S. Trench Safe Plan Utility lines Coppell Service Center Coppell, Texas for: N CENTRAL PLUMBING Job No: 4694 ic ard a er Date :06 May 2008 Trench Safety Engineering 833 Rachelle Scale : As shown Red Oak Texas 75154 Design: R.H. 1-800-900-9775