Loading...
Arbor Manors-LR080416 05/14/2008 12:55 9724058023 ALPHA TESTING PAGE 09/15 '~'\A TESTING. INC. 2209 Wisconsin St.. Sulfa 100 Do/los. Taxas 75229 972/62(HJ911 - 972/263.4937 (Metro) FAX: 9721406"802~ ex REPORT OF FIELD COMPACTION TESTS TESTED FOR: John Baker Corporation CIO Priority Development, LP Houston. TEXAS DATE: 04/16/08 PROJECT Arbor Manors Coppell. Texas OUR REPORT NO.: 080332-10 TEST DATA TEST ~ SOIL 10 OPTIMuM IAAllIMUM LAB IN PLACF. IN PlACE PERCENT NO. DATE DEPTH NUMBER MOISTVQE DRY DENSITY MOI$TUR[;, DRY OENSITY COMPACTION COMMENT" 'K PCF % PCI' 71 04/16/08 SG 1 11.6 111.7 13.4 107 96 2-A 72 04/16/08 SG 1 11.6 111.7 13.6 107 96 2-A 73 04/16/08 SO 1 11.6 111.7 12.0 110 99 2-A 74 04/16/08 SG 1 11.6 111,7 13.4 107 96 2-A 75 04/16/08 SG 1 11.6 111.7 12.9 111 99 2.A 76 04/16/08 FG-1.0 1 11.6 111.7 13.6 106 95 2.A 77 04/16/0a FG-1.0 1 11.6 111.7 12.8 108 96 2-A TEST LOCATION' PADS 71 3D' SOUTH AND 60' EAST FROM THE NORTHWEST CORNER OF BLOCK D. PAD 1 72 40' SOUTH AND 3D' EAST FROM THE NORTHWEST CORNE~ OF BLOCK D, PAD 3 73 30' SOUTH AND 30' EAST FROM THE NORTHWEST CORNER OF BLOCK D. PAD 5 74 50' SOUTH AND 25' EAST FROM THE NORTHWEST CORNER OF BLOCK 0, PAO 7 75 70' SOUTH AND 30' EAST FROM THE NORTHWEST CORNER OF BLOCK D, PAD 9 76 40' SOUTH AND 20' EAST FROM THE NORTHWEST CORNER OF BLOCK D. PAD 6 77 60' SOUTH AND 25' EAST FROM THE NORTHWEST CORNER OF BLOCK D. PAD 8 1. FILL ?. NATURAL SUBGRADE 3. LIME STABILlZEO ~. CEMENT TREA TEO "A. IN PLACE PERCENT MOISTURE ANO PERCENT COMPACTION COMPl YWITH SPECIFIC.&.TIONS B. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS C PERCENT IN PLACE MOISTURE ODES NOT COMP~ Y WITH SPECIFICATIONS D. RETEST ~='~ samllson CMEln ALPHA TESTING, INC. Our hut ~8u1l8 11M '"ApO"~ ;\fO lor Lhe It)(c\u8Ivt v... at It"Ia Clilnl (Bf'1lj 'heir dasigl"leled 'lclOl.-n'. Dn Pila I" oyr omoe) ."eII"".n net ba reproduce" andIDr dl~lrtblJ'ed "oe~l Wah &I'l:p'", R~p",""1 or AL.PHA, The lJ!A) of our nem9 I;tnd hnt nnulls rnuU reCeive O\,!r 'W'I'lltfll" IlIppro\/81, T...t rn~ull~ ISl"Id report. f'''~ly a"ly 10 It'le !Amplel 'etlt~d nnd/or Db~f1rv8d. Ind 8'" nOI, indicativa of tht:r Qualities cf . poef.olly id.nU<:lI1 or oimilcf epeel","". Geotechnical Engineering & Construction Materials Testing & Environmental Engineering & Consulting 05/15/2008 10:09 97240&8023 ALPHA TESTING PAGE 10/1& I~A rESTING. INC. 2209 W/!JCons/n St., Suite tOO Ool/OS, Texas 75229 972/62O-lJ911 - 9721263-4937 (Metro) FAX: 972/406-8023 ex REPORT OF FIELD COMPACTION TESTS PROJECT: John Baker Corporation C/O Priority Development, LP Houston, TEXAS Arbor Manors Coppell, Texas DATE: 04/16/08 TESTED FOR: OU~ REPORT NO,: OB0332.10A TEST DATA TEST ~ SOILID OPTIMUM MAXIMUM l"e IN PLAce IN PLACE PEACENT DATE MOISTUI'lE DRY DEN6m' MOISTURE DRY DENSITY COMMENT- NO. DEP-rH NUMBER \40 PC~ ,.. PCF COMPACTION 78 D4f16f08 FG-4.2 1 11.6 111.7 13.4 107 96 1-A 79 04/16/06 FG-3.3 1 11.6 111.7 12.9 108 97 1-A 80 04/16/08 FG-4.3 1 11,6 111.7 11.9 111 99 1-A 81 04f16/08 FG-3.2 1 11.6 111.7 13.4 107 96 1-A 82 04/16/06 FG-4.4 1 11.6 111.7 11.1 110 99 1-A 83 04/16/08 FG-3.3 1 11.6 111.7 13.4 107 96 '-A 84 04f16/0B FG-Z.3 1 11.6 111.7 12.5 108 97 1-A TEST LOCATION' PADS 78 60' SOUTH AND 30' EAST FROM THE NORTHWEST CORNER OF BLOCK B. PAD 2 79 40' SOUTH AND 20' EAST FROM THE NORTHWEST CORNER OF BLOCK B, PAD 4 80 50' SOUTH AND 25' EAST FROM THE NORTHWEST CORNER OF BLOCK B PAD 6 81 30' SOUTH AND 60' EAST FROM THE NORTHWEST CORNER OF BLOCK B, PAD 8 82 40' SOUTH AND 40' EAST FROM THE NORTHWEST CORNER OF BLOCK S, PAD 9 83 30' SOUTH AND 40' EAST FROM THE NORTHWEST CORNER OF BLOCK e, PAD 6 84 40' SOUTHA NO 60' EAST FROM THE NORTHWEST CORNER OF BLOCK 8. PAD 6 1 FILL 2 NATURALSUBGRADE :!. LIME STABILIZED ~, CEMENT TREATEO . A. IN PlACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS B PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS C PERCENT IN PLACE MOISTURE DOES NOT COMPLY wrl'H SPECIFICATIONS D. RETEST ~'~ Samp90n Chan ALPHA -reSTING. INC. Our l&!l ruu\u I:Ind t'apane er. fer tho $)(cl...,I\la us. ", tf"le Cll1:'f\1 (;\nd tt"lelr d'lIlgnll1ed l.eiplenlJ an '.a II'l our amt:.lI) oiJnd _"...11 not bA rapr'O'du~cI..nd/or dl:iUib\II'td .ltl:apt wi'~ ei:p'~.~ IIIpprcv.1 af ALPHA. Th<! ule 01 our n~",e end le'l ""ulls mu!\ '8(01'0 our wrlllen ,pp'"".1 Te81 ro..,ll. 8nd ,.po~' APPly onlV 10 Ih. .~~I"'''lOd ~ndl1>r Dbl.",.d. end ara nol indiG&l'i.e Df 1M qu~'ltI.~ of ~pp8'ent!y IdAn!it:)1 Of 6lmlllu r.pDe:;",enl, Geotechnical Engineering & Construction Materials Testing & Environmental Engineering & Consulting