Vista Ridge Retail-LR080428 CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94071386.0081 Service Date: April 17, 2008 lrerracon 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630-1010 Client: United Commercial Devel Attn: Robert Dorazil 7001 Preston Rd Ste 500 Dallas TX 75205 Report Date: April 28, 2008 Project: Vista Ridge Retail Lots 6 & 7 NEC of 121 & Denton Tap Rd. Coppell, TX OGallons o Gallons Project No.: 94071386 Sample Information Date Cast: April 17, 2008 Time: 1 :50pm Sampled by: Terry Smith InsplTesting Weather Conditions: Partly cloudy, windy Accumulative Yards: 320/350 Batch Size (cy): 10.00 Placement Method: Direct Discharge Sample Locations: 20' S & 40' E of NW corner Placement Location: Parking Lot, North End, Middle Section Material Information Specified Strength: 3600 psi @ 28 Days Batch Time: 1 :13pm Supplier: Redi-Mix Truck No: 1874 Mix I.D. No.: 336K1504 Water Added Onsite Before Test: Water Added Onsite After Test: Plant: 2259 Ticket No: 59025021 Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature, of: Ambient Temperature, of: Plastic Unit Weight, pef: Result 5.50 Specification Test Method ASTM C143 ASTM C231 ASTM C 1064 ASTM C1064 ASTM C138 70 69 Laboratory Test Data Set No. 4 4 4 4 Specimen 10 1 2 3 4 Diameter Area (inches) (sq. inches) 4.00 12.57 Date Tested 04/24/2008 05/15/2008 05/15/2008 06/12/2008 Age at Test (days) 7 28 28 56 Maximum Compressive Load Strength (Ibs) (psi) 50,610 4,030 Comments: Not tested for plastic unit weight. Services _ Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Terraeon Rep: Terry Smith InsplTesting Report Distribution: (1) United Commercial Oevel (1) Winkelmann & Assoc Inc (1) City of Coppel! TX (1) Lee Lewis Construction Inc (1) O'Brien & Assoc (1) Hunt & Joiner Inc Reviewed by: A. Bulent Ethem, P.G. Project Manager The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 4 of 4 01-M'\NBIRO,-future Kay CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94071386.0081 Service Date: April 17, 2008 , rerracon 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630-1010 Client: United Commercial Devel Attn: Robert Dorazil 7001 Preston Rd Ste 500 Dallas TX 75205 Material Information Specified Strength: 3600 psi @ 28 Days Plant: 2259 Batch Time: 11 :42am Supplier: Redi-Mix Truck No: 1211 Mix I.D. No.: 336K1504 Water Added Onsite Before Test: Water Added Onsite After Test: Ticket No: 59024999 o Gallons 5 Gallons Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature, of: Ambient Temperature,oF Plastic Unit Weight, pcf: Report Date: April 28, 2008 Project: Vista Ridge Retail Lots 6 & 7 NEC of 121 & Denton Tap Rd. Coppell, TX Project No.: 94071386 Sample Information Date Cast: April 17, 2008 Time: 12:00pm Sampled by: Terry Smith Insp/Testing Weather Conditions: Partly cloudy, windy Accumulative Yards: 250/300 Batch Size (cy): 10.00 Placement Method: Direct Discharge Sample Locations: 60' S & 50' W of NE corner Placement Location: Parking Lot, North End, Middle Section Result 5.50 Specification 72 69 Laboratory Test Data Set No. 3 3 3 3 Specimen ID 1 2 3 4 Diameter Area (inches) (sq. inches) 4.00 12.57 Date Tested 04/24/2008 05/15/2008 05/15/2008 06/12/2008 Test Method ASTM C143 ASTM C231 ASTM C1064 ASTM C 1064 ASTM C138 Age at Test (days) 7 28 28 56 Maximum Compressive Load Strength (Ibs) (psi) 40,910 3,260 Comments: Not tested for plastic unit weight. Services _ Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 3 of 4 01-MVVBIR01-FulUfIl Key CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94071386.0081 Service Date: April 17, 2008 lrerracon 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630-1010 Client: United Commercial Devel Attn: Robert Dorazil 7001 Preston Rd Ste 500 Dallas TX 75205 Report Date: April 28, 2008 Project: Vista Ridge Retail Lots 6 & 7 NEC of 121 & Denton Tap Rd. Coppell, TX OGallons 5 Gallons Project No.: 94071386 Sample Information Date Cast: April 17, 2008 Time: 10:35am Sampled by: Terry Smith Insprresting Weather Conditions: Partly cloudy, windy Accumulative Yards: 140/300 Batch Size (cy): 10.00 Placement Method: Direct Discharge Sample Locations: 110' S & 70' W of NE corner Placement Location: Parking Lot, North End, Middle Section Material Information Specified Strength: 3600 psi @ 28 Days Batch Time: 9:48am Supplier: Redi-Mix Truck No: 1286 Mix I.D. No.: 336K1504 Water Added Onsite Before Test: Water Added Onsite After Test: Plant: 2259 Ticket No: 59024977 Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature, of: Ambient Temperature,oF: Plastic Unit Weight, pcf: Result 5.00 Specification Test Method ASTM C143 ASTM C231 ASTM C 1064 ASTM C 1064 ASTM C138 70 60 Laboratory Test Data Set No. 2 2 2 2 Specimen ID 1 2 3 4 Diameter Area (inches) (sq. inches) 4.00 12.57 Date Tested 04/24/2008 05/15/2008 05/15/2008 06/12/2008 Age at Test (days) 7 28 28 56 Maximum Compressive Load Strength (Ibs) (psi) 47,960 3,820 Comments: Not tested for plastic unit weight. Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 2 of 4 01-M'NBIR01-Future Key CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94071386.0081 Service Date: April 17, 2008 lrerracon 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630-1 01 0 Client: United Commercial Devel Attn: Robert Dorazil 7001 Preston Rd Ste 500 Dallas TX 75205 Report Date: April 28, 2008 Project: Vista Ridge Retail Lots 6 & 7 NEC of 121 & Denton Tap Rd. Coppell, TX o Gallons o Gallons Project No.: 94071386 Sample Information Date Cast: April 17, 2008 Time: 9:10am Sampled by: Terry Smith Insp/Testing Weather Conditions: Partly cloudy, windy Accumulative Yards: 80/300 Batch Size (cy): 10.00 Placement Method: Direct Discharge Sample Locations: 300' S & 70' E of NW corner Placement Location: Parking Lot, North End, Middle Section Materia/Information Specified Strength: 3600 psi @ 28 Days Batch Time: 8:22am Supplier: Redi-Mix Truck No: 1352 Mix I.D. No.: 336K1504 Water Added On site Before Test: Water Added Onsite After Test: Plant: 2259 Ticket No: 95024955 Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature, of Ambient Temperature,oF Plastic Unit Weight, pcf: Result 5.5 Specification Test Method ASTM C143 ASTM C231 ASTM C1064 ASTM C 1064 ASTM C138 68 60 Laboratory Test Data Set No. 1 1 1 1 Specimen ID 1 2 3 4 Diameter Area (inches) (sq. inches) 4.00 12.57 Date Tested 04/24/2008 05/15/2008 05/15/2008 06/12/2008 Age at Test (days) 7 28 28 56 Maximum Compressive Load Strength (Ibs) (psi) 53,600 4,260 Comments: Not tested for plastic unit weight. Services _ Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 4 Ol.M"NBIR01-FutureKey