Chicken Express-LR080521 l rio~ ., Information ~..,. .To Build On Engine""'" . Consulting . JHtfng REPORT OF CONCRETE COMPRESSION TEST TESTED FOR: RANDY HYNES RANDY HYNES GENERAL CONTRACTOR 101 TRINITY VIEW RD WEATHERFORD, TX 76087 DATE: May 21, 2008 PSI REPORT NO.: 341-80040-4 FIELD DATA: LOCATION OF PLACEMENT PROJECT: CHICKEN EXPRESS RESTAURANT COPPELL, TX Paving Beltline Westbound Right Turn Lane DATE PLACED TIME SLUMP, IN. AIR CONTENT, % AIR TEMPERATURE, OF CONCRETE TEMPERATURE OF DATE RECEIVED IN LAB FIELD DATA SUBMITTED BY MIX DATA SUBMITTED BY May 21, 2008 01 : 45 pm 5 1/2 5.2 77 82 May 22, 2008 PSI\Ronnie Yeoman Southern Star SUPPLIER DELIVERY TICKET NO/TRUCK NO. MIX NUMBER AND PROPORTIONS CEMENT WATER FINE AGGREGATE COARSE AGGREGATE ADMIXTURE Southern Star 1271448 9375 NOTE' APPLICABLE ASTM STANDARDS UNLESS on.IERWISE INDICATED' SLUMP' C143' AIR CONTENT' C231 (EXCLUDING see 6)' TEMPERATURE- C1084' CYLINDERS' C31 (EXCLUDING SEe 1012\' SAMPLING' C172 COMPRESSION TEST RESULTS ASTM C39; C1231 SPECIMEN TEST TOTAL CYLINDER CYLINDER COMPRESSIVE TYPE OF BREAK, LABORATORY IDENTIFICATION AGE DATE OF LOAD DIAMETER AREA STRENGTH AS SHOWN IN NUMBER OR SET NO. (DAYS) TEST (LBS.) (IN.) (sa. IN.) (PSI) ASTM C39 935 A 7 OS/28/08 95420 6.00 28.27 3380 Type 3 935 B 28 06/18/08 935 C 28 06/18/08 935 D H HOLD SPECIFICATIONS 28 4500 REMARKS: ~ Cylinders made by PSI representative. Cylinders picked up by PSI ~ representative. Cylinders made by Architect's or Contractor's representative. Test results comply with applicable specifications. Cylinders delivered to PSI laboratory. Test results do not compiy with applicable specifications. TECHNICIAN: William Miller cc: Hynes Respectfully submitted, Professional Service Industries, Inc. THESE TEST RESULTS APPl Y ONLY TO THE SPECIFIC SAMPLES TESTED AND MAY NOT BE INDICATIVE OF THE ENTIRE CONCRETE PLACEMENT. REPORTS MAY NOT BE REPRODUCED. EXCEPT IN FUll. WITHOUT WRITTEN PERMISSION BY PROFESSIONAL SERVICE INDUSTRIES. INC. PSI A-200-4N F Professional Service Industries, Inc.. 4087 Shilling Way. Dallas, TX 75237. Phone 214/330-9211 . Fax 214/467-0031 l-,,~.'InfomwJion ~~. .To Build On EngIneerfng . Consulllng . TestIng REPORT OF FIELD TESTING OF CONCRETE TESTED FOR: RANDY HYNES RANDY HYNES GENERAL CONTRACTOR 101 TRINITY VIEW RD WEATHERFORD, TX 76087 PROJECT: CHICKEN EXPRESS RESTAURANT COPPELL, TX DATE: May 21, 2008 PSI REPORT NO.: 341-80040-3 FIELD DATA: Concrete was a 4500 psi mix delivered by Southern Star, mix number 9375. NO. OF CONCRETE CUBIC TEMPERATURE, OF SPECIMENS SUPPLIER TIME TRUCK TIME TRUCK YARDS OF AIR SET NO. MADE TICKET NUMBER DISPATCHED UNLOADED CONCRETE SLUMP, in. CONTENT, % AIR CONCRETE 935 4 1271448 01:12 pm 02:00 pm 9.0 5 1/2 5.2 77 82 lOCATION: Paving 935 Beltline Westbound Right Turn Lane NOTE: APPLICABLE ASTM STANDARDS. UNLESS OTHERWISE INDICATED: MAKING SPECIMENS: C31 (EXC. SEC. 10 1.2): SLUMP: C143; AIR CONTENT C231 (EXC. SEC. 6); TEMPERATURE: C1064; SAMPLING: C172 REMARKS: TECHNICIAN: Ronnie Yeoman Respectfully submitted, Professional Service Industries, Inc. cc: Hynes THESE TEST RESULTS APPLY ONLY TO THE SPECIFIC SAMPLES TESTED AND MAY NOT BE INOlCA TIVE OF THE ENTIRE CONCRETE PLACEMENT REPORTS MAY NOT BE REPROOUCED. EXCEPT IN FULL. WITHOUT WRITTEN PERMISSION BY PROFESSIONAL SERVICE INDUSTRIES, INC. PSI A-200-1 (6)F Professional Service Industries, Inc.. 4087 Shilling Way. Dallas, TX 75237. Phone 214/330-9211 . Fax 214/467-0031