Loading...
Chicken Express-LR080701 l n.f: ;1 InfoT71Ultion ~.,. .To Build On Engineering. Consulting. nesting REPORT OF FIELD TESTING OF CONCRETE TESTED FOR: RANDY HYNES RANDY HYNES GENERAL CONTRACTOR 101 TRINITY VIEW RD WEATHERFORD, TX 76087 PROJECT: DATE: July 01, 2008 PSI REPORT NO.: 341- 80040 -15 FIELD DATA: Concrete was a 3500 psi mix delivered by Southern Star, mix number 9341. SET NO NO. OF . SPECIMENS MADE CONCRETE SUPPLIER TICKET NUMBER TIME TRUCK DISPATCHED TIME TRUCK UNLOADED CUBIC YARDS OF CONCRETE SLUMP. ,n. AIR CONTENT, % TEMPERATURE. of AIR CONCRETE 1305 4 1302639 06:00 am 06:45 am 50.0 5 4.2 76 85 LOCATION: Slab-an-Grade 1305 15' South by 10' West of Northeast Corner of Building, Slab NOTE APPLICABLE ASTM STANOARDS. UNLESS OTHERWISE INDICA TED MAKING SPECIMENS C31 (EXC SEC. 10 12) SLUMP, C 143: AIR CONTENT C231 (EXC SEC. 6), TEMPERATURE, C 1064: SAMPLING, C 172 REMARKS: TECHNICIAN: Kirk See Respectfully submitted, Professional Service Industries, Inc. cc: Hynes; Davis; Stone THESE TEST RESULTS APPLY ONL Y TO THE SPECIFIC SAMPLES TESTED AND MAY NOT BE INDICATIVE OF THE ENTIRE CONCRETE PLACEMENT REPORTS MAY NOT BE REPROOUCED. EXCEPT IN FULL. WITHOUT WRITTEN PERMISSION BY PROFESSIONAL SERVICE INDUSTRIES. INC PSI A-ZOO. 1 (8)F Professional Service Industries, Inc.. 4087 Shilling Way. Dallas, TX 75237. Phone 214/330-9211 . Fax 214/467-0031 l-}~ il Information ~.,. .To Build On Engineering. Consulting. 'Ji!sflng REPORT OF CONCRETE COMPRESSION TEST TESTED FOR: RANDY HYNES RANDY HYNES GENERAL CONTRACTOR 101 TRINITY VIEW RD WEATHERFORD, TX 76087 PROJECT: CHICKEN EXPRESS RESTAURANT COPPELL, TX DATE: July 01, 2008 PSI REPORT NO.: 341-80040-16 FIELD DATA: LOCATION OF PLACEMENT Slab-on-Grade 15' South by 10' West of Northeast Corner of Building, Slab DATE PLACED July 01, 2008 SUPPLIER Southern Star TIME 06:35 am DELIVERY TICKET NO.ITRUCK NO. 1302639 SLUMP, IN. 5 MIX NUMBER AND PROPORTIONS 9341 AIR CONTENT, % 4.2 CEMENT AIR TEMPERATURE, of 76 WATER CONCRETE TEMPERATURE of 85 FINE AGGREGATE DATE RECEIVED IN LAB July 02, 2008 COARSE AGGREGATE FIELD DATA SUBMITTED BY PSI\Kirk See ADMIXTURE MIX DATA SUBMITTED BY Southern Star NOTE- APPLICABLE ASTM STANDARDS UNLESS OTHERWISE INDICATED' SLUMP' C143' AIR CONTENT- C231 (EXCLUDING SEe 6)' TEMPERATURE' Cl064' CYLINDERS- C31 (EXCLUDING SEe 1012\" SAMPLING' C172 COMPRESSION TEST RESULTS ASTM C39; C1231 A B C o DATE OF TEST TOTAL LOAD (LBS.) CYLINDER DIAMETER (IN.) COMPRESSIVE TYPE OF BREAK. AS SHOWN IN ASTM C39 SPECIMEN LABORATORY IDENTIFICATION NUMBER OR SET NO. 1305 1305 1305 1305 07/08/08 07/29/08 07/29/08 HOLD 80190 6.00 Type 3 SPECIFICATIONS 28 3500 REMARKS: X Cylinders made by PSI representative. Cylinders picked up by PSI ~ representative. Test results comply with applicable specifications. Cylinders made by Architect's or Contractor's representative. Cylinders delivered 10 PSI laboratory. Test results do not comply wilh applicable specifications. TECHNICIAN: William Miller Respectfully submitted, Professional Service Industries, Inc. cc: Hynesi Davisi Stone THESE TEST RESULTS APPLY ONLY TO THE SPECIFIC SAMPLES TESTED AND MAY NOT BE INDICATIVE OF THE ENTIRE CONCRETE PLACEMENT REPORTS MAY NOT BE REPROOUCED, EXCEPT IN FULL. WITHOUT WRITTEN PERMISSION BY PROFESSIONAL SERVICE INDUSTRIES, INC PSI A-2OQ-4N F Professional Service Industries, Inc.. 4087 Shilling Way. Dallas, TX 75237. Phone 214/330-9211 . Fax 214/467-0031