Chicken Express-LR080701
l n.f: ;1 InfoT71Ultion
~.,. .To Build On
Engineering. Consulting. nesting
REPORT OF FIELD TESTING OF CONCRETE
TESTED FOR:
RANDY HYNES
RANDY HYNES GENERAL CONTRACTOR
101 TRINITY VIEW RD
WEATHERFORD, TX 76087
PROJECT:
DATE:
July 01, 2008
PSI REPORT NO.: 341- 80040 -15
FIELD DATA:
Concrete was a 3500 psi mix delivered by Southern Star,
mix number 9341.
SET NO
NO. OF
. SPECIMENS
MADE
CONCRETE
SUPPLIER
TICKET NUMBER
TIME TRUCK
DISPATCHED
TIME TRUCK
UNLOADED
CUBIC
YARDS OF
CONCRETE
SLUMP. ,n.
AIR
CONTENT, %
TEMPERATURE. of
AIR CONCRETE
1305
4
1302639
06:00 am
06:45 am
50.0
5
4.2
76
85
LOCATION:
Slab-an-Grade
1305
15' South by 10' West of Northeast Corner of Building, Slab
NOTE APPLICABLE ASTM STANOARDS. UNLESS OTHERWISE INDICA TED MAKING SPECIMENS C31 (EXC SEC. 10 12) SLUMP, C 143: AIR CONTENT C231 (EXC SEC. 6), TEMPERATURE, C 1064: SAMPLING, C 172
REMARKS:
TECHNICIAN:
Kirk See
Respectfully submitted,
Professional Service Industries, Inc.
cc: Hynes; Davis; Stone
THESE TEST RESULTS APPLY ONL Y TO THE SPECIFIC SAMPLES TESTED AND MAY NOT BE INDICATIVE OF THE ENTIRE CONCRETE PLACEMENT
REPORTS MAY NOT BE REPROOUCED. EXCEPT IN FULL. WITHOUT WRITTEN PERMISSION BY PROFESSIONAL SERVICE INDUSTRIES. INC
PSI A-ZOO. 1 (8)F
Professional Service Industries, Inc.. 4087 Shilling Way. Dallas, TX 75237. Phone 214/330-9211 . Fax 214/467-0031
l-}~ il Information
~.,. .To Build On
Engineering. Consulting. 'Ji!sflng
REPORT OF CONCRETE COMPRESSION TEST
TESTED FOR:
RANDY HYNES
RANDY HYNES GENERAL CONTRACTOR
101 TRINITY VIEW RD
WEATHERFORD, TX 76087
PROJECT: CHICKEN EXPRESS RESTAURANT
COPPELL, TX
DATE:
July 01, 2008
PSI REPORT NO.: 341-80040-16
FIELD DATA:
LOCATION OF PLACEMENT
Slab-on-Grade
15' South by 10' West of Northeast Corner of Building, Slab
DATE PLACED July 01, 2008 SUPPLIER Southern Star
TIME 06:35 am DELIVERY TICKET NO.ITRUCK NO. 1302639
SLUMP, IN. 5 MIX NUMBER AND PROPORTIONS 9341
AIR CONTENT, % 4.2 CEMENT
AIR TEMPERATURE, of 76 WATER
CONCRETE TEMPERATURE of 85 FINE AGGREGATE
DATE RECEIVED IN LAB July 02, 2008 COARSE AGGREGATE
FIELD DATA SUBMITTED BY PSI\Kirk See ADMIXTURE
MIX DATA SUBMITTED BY Southern Star
NOTE- APPLICABLE ASTM STANDARDS UNLESS OTHERWISE INDICATED' SLUMP' C143' AIR CONTENT- C231 (EXCLUDING SEe 6)' TEMPERATURE' Cl064' CYLINDERS- C31 (EXCLUDING SEe 1012\" SAMPLING' C172
COMPRESSION TEST RESULTS
ASTM C39; C1231
A
B
C
o
DATE OF
TEST
TOTAL
LOAD
(LBS.)
CYLINDER
DIAMETER
(IN.)
COMPRESSIVE
TYPE OF BREAK.
AS SHOWN IN
ASTM C39
SPECIMEN
LABORATORY IDENTIFICATION
NUMBER OR SET NO.
1305
1305
1305
1305
07/08/08
07/29/08
07/29/08
HOLD
80190
6.00
Type 3
SPECIFICATIONS
28
3500
REMARKS: X Cylinders made by PSI representative.
Cylinders picked up by PSI
~ representative.
Test results comply with applicable
specifications.
Cylinders made by Architect's or
Contractor's representative.
Cylinders delivered 10 PSI laboratory.
Test results do not comply wilh
applicable specifications.
TECHNICIAN:
William Miller
Respectfully submitted,
Professional Service Industries, Inc.
cc: Hynesi Davisi Stone
THESE TEST RESULTS APPLY ONLY TO THE SPECIFIC SAMPLES TESTED AND MAY NOT BE INDICATIVE OF THE ENTIRE CONCRETE PLACEMENT
REPORTS MAY NOT BE REPROOUCED, EXCEPT IN FULL. WITHOUT WRITTEN PERMISSION BY PROFESSIONAL SERVICE INDUSTRIES, INC
PSI A-2OQ-4N F
Professional Service Industries, Inc.. 4087 Shilling Way. Dallas, TX 75237. Phone 214/330-9211 . Fax 214/467-0031