Loading...
Chicken Express-LR080711 l-"~;l Info171Ultion ~~. .To Build On EngI"",*,,, · ConsultIng · JUtlIIfI REPORT OF FIELD TESTING OF CONCRETE TESTED FOR: RANDY HYNES RANDY HYNES GENERAL CONTRACTOR 101 TRINITY VIEW RD WEATHERFORD, TX 76087 PROJECT: CHICKEN EXPRESS RESTAURANT COPPELL, TX DATE: July 11, 2008 PSI REPORT NO.: 341-80040-22 FIELD DATA: Concrete was delivered by Southern Star, mix number 9351. NO. OF CONCRETE CUBIC i TEMPERATURE, 'F I SPECIMENS SUPPLIER TIME TRUCK TIME TRUCK YARDS OF AIR CONCRETE -1 SET NO. MADE TICKET NUMBER DISPATCHED UNLOADED CONCRETE SLUMP, in. CONTENT, % AIR 1402 1311112 I 09:00 1/2 \ 4 I 08:35 am am 80.0 5 3.5 89 92 I 1403 4 1311326 10:37 am 11:10 am 170.0 5 4.0 91 93 I i 1404 4 i 1311615 12:50 pm 01:40 pm 180.0 4 1/2 4.0 98 99 i -1 , i i i I I I i LOCATION: Paving 1402 10' into Northeast Corner of Driveway/Parking Lot i ! 1403 15' West by 50 I South from Entrance of Main Road (Beltline) I 1404 12' North from Entrance of Driveway -I \ I I I NOTE APPLICABLE ASTM STANDARDS, UNLESS OTHERWISE INDICATED MAKING SPECIMENS. C3' (EXC. SEC. '0 12): SLUMP: C 143: AIR CONTENT C23' (EXC. SEC. 6): TEMPERATURE: C1 064: SAMPLING C 172 REMARKS: Observed the placement of 300.0 cubic yards of concrete. TECHNICIAN: Randy Ihnfeldt Respectfully submitted, Professional Service Industries, Inc. cc: Hynes; Davis; Stone THESE TEST RESULTS APPL Y ONLY TO THE SPECIFIC SAMPLES TESTED AND MAY NOT BE INDICATIVE OF THE ENTIRE CONCRETE PLACEMENT REPORTS MAY NOT BE REPRODUCED, EXCEPT IN FULL, WITHOUT WRITTEN PERMISSION BY PROFESSIONAL SERVICE INDUSTRIES. INC PSI A.200.' (81F Professional Service Industries, Inc.. 4087 Shilling Way. Dallas, TX 75237' Phone 214/330-9211 . Fax 214/467-0031