Chicken Express-LR080709
l."~ ;1 Information
~~. .To Build On
Engineering · Consulting · ~ng
REPORT OF FIELD TESTING OF CONCRETE
TESTED FOR:
RANDY HYNES
RANDY HYNES GENERAL CONTRACTOR
101 TRINITY VIEW RD
WEATHERFORD, TX 76087
PROJECT:
CHICKEN EXPRESS RESTAURANT
COPPELL, TX
DATE:
July 09, 2008
PSI REPORT NO.: 341-80040-19
FIELD DATA:
Concrete was delivered by Southern Star, mix number 9351.
I NO.OF CONCRETE CUBIC I TEMPERATURE, OF
SPECIMENS SUPPLIER TIME TRUCK TIME TRUCK YARDS OF AIR
SET NO MADE TICKET NUMBER DISPATCHED UNLOADED CONCRETE SLUMP, In CONTENT, % AIR CONCRETE
I 1381 4 1308262 05:02 am 05:32 am 30.0 5 [ 4.5 79 91
I
I 1382 4 1308425 07:13 07:53 120.0 5 1/4 I 4.7 78 90
I am am
i I
I
! I
I
I
I
I
!
I
I i
I
LOCATION:
Parking Lot/Firelane
1381 30' North, 120' West from the Northwest Corner of Pad
1382 35' North, 20' West from the Southwest Corner of Pad
I I
NOTE: APPLICABLE ASTM STANDARDS, UNLESS OTHERWISE INDICATED: MAKING SPECIMENS: C31 (EXC. SEC 101,2): SLUMP C143: AIR CONTENT: C231IEXC, SEC. B): TEMPERATURE Cl0B4: SAMPLING: C172
REMARKS: Observed the placement of 200.0 cubic yards of concrete.
TECHNICIAN:
Godfrey White
Respectfully submitted,
Professional Service Industries, Inc.
cc: Hynesj Davisj Stone
THESE TEST RESULTS APPLY ONL Y TO THE SPECIFIC SAMPLES TESTED AND MAY NOT BE INDICATIVE OF THE ENTIRE CONCRETE PLACEMENT
REPORTS MAY NOT BE REPRODUCED, EXCEPT IN FULL, WITHOUT WRITTEN PERMISSION BY PROFESSIONAL SERVICE INDUSTRIES, INC.
PSI A-200-1 (BIF
Professional Service Industries, Inc.. 4087 Shilling Way. Dallas, TX 75237. Phone 214/330-9211 . Fax 214/467-0031
l....~;l Information
~..". .To Build On
Ellfllnea"'" · c...ItIng · ntsfIng
..
n /,fl,
7/t"e )~g~
REPORT OF CONCRETE COMPRESSION TEST
TESTED FOR:
RANDY HYNES
RANDY HYNES GENERAL CONTRACTOR
101 TRINITY VIEW RD
WEATHERFORD, TX 76087
DATE:
July 09, 2008
PSI REPORT NO.: 341-80040-20
FIELD DATA:
LOCATION OF PLACEMENT
PROJECT:
Parking LotjFirelane
30' North, 120' West from the Northwest Corner of Pad
DATE PLACED
TIME
SLUMP, IN.
AIR CONTENT, %
AIR TEMPERATURE, OF
CONCRETE TEMPERATURE
DATE RECEIVED IN LAB
FIELD DATA SUBMITTED BY
MIX DATA SUBMITTED BY
July 09, 2008
05:16 am
5
4.5
79
OF 91
July 10, 2008
PSI\Godfrey White
Southern Star
SUPPLIER
DELIVERY TICKET NO.fTRUCK NO.
MIX NUMBER AND PROPORTIONS
CEMENT
WATER
FINE AGGREGATE
COARSE AGGREGATE
ADMIXTURE
Southern
1308262
9351
5.5 SK
Star
NOTE: APPLICABLE ASTM STANDARDS UNLESS OTHERWISE INDICAT~O SLUMp. C143- AIR CONTENT- C231 (EXCLUDING SEe 6)" TEMPERATURE: C1064" CYLINDERS. C31 (EXCLUDING SEe 1012)" SAMPLING. C172
COMPRESSION TEST RESULTS
ASTM C39; C 1231
SPECIMEN TEST TOTAL CYLINDER CYLINDER COMPRESSIVE TYPE OF BREAK.
LABORATORY IDENTIFICATION AGE DA TE OF LOAD DIAMETER AREA STRENGTH AS SHOWN IN
NUMBER OR SET NO. (DAYS) TEST (LBS.) (IN.) (sa. IN.) ASTM C39
1381 A 7 07/16/08 99400 6.00 Type 2
1381 B 7 07/16/08 102750 6.00 Type 3
1381 C 28 08/06/08
1381 D 28 08/06/08
I SPECIFICATIONS
28
REMARKS: X Cylinders made by PSI representalive.
Cylinders picked up by PSI
K representative
Cylinders made by Architect's or
Contractor's representative.
3000
Test results comply with applicable
specifications.
Cylinders delivered to PSI laboratory.
Test results do not comply with
applicable specifications
TECHNICIAN:
William Miller
cc: Hynes; Davis; Stone
Respectfully submitted,
Professional Service Industries, Inc.
THESE TEST RESULTS APPL Y QNL Y TO THE SPECIFIC SAMPLES TESTED AND MAY NOT BE INDICATIVE OF THE ENTIRE CONCRETE PLACEMENT.
REPORTS MAY NOT BE REPRODUCED. EXCEPT IN FULL. WITHOUT WRITTEN PERMISSION BY PROFESSIONAL SERVICE INDUSTRIES. INC
PSI A-200-4N F
Professional Service Industries, Inc.. 4087 Shilling Way. DaHas, TX 75237. Phone 214/330-9211 . Fax 214/467-0031
l- ,,~., ['!formation
~.,. .To Build On
Engineering . ConsultIng · Tutlng
REPORT OF CONCRETE COMPRESSION TEST
TESTED FOR:
RANDY HYNES
RANDY HYNES GENERAL CONTRACTOR
101 TRINITY VIEW RD
WEATHERFORD, TX 76087
DATE:
July 09, 2008
PSI REPORT NO.: 341-80040-21
PROJECT: CHICKEN EXPRESS RESTAURANT
COPPELL, TX
FIELD DATA:
LOCATION OF PLACEMENT
Parking Lot/Firelane
35' North, 20' West from the Southwest Corner of Pad
DATE PLACED
TIME
SLUMP, IN.
AIR CONTENT, %
AIR TEMPERATURE, of
CONCRETE TEMPERATURE
DATE RECEIVED IN LAB
FIELD DATA SUBMITTED BY
MIX DATA SUBMITTED BY
July 09, 2008
07:38 am
5 1/4
4.7
78
of 90
July 10, 2008
PSI\Godfrey White
Southern Star
SUPPLIER
DELIVERY TICKET NO.rrRUCK NO.
MIX NUMBER AND PROPORTIONS
CEMENT
WATER
FINE AGGREGATE
COARSE AGGREGATE
ADMIXTURE
Southern
1308425
9351
5.5 SK
Star
NOTE: APPLICABLE ASTM STANDARDS UNLESS OTHERWISE INDICATED' SLUMP: C143' AIR CONTENT' C2311EXCLUDING SEC, 6)" TEMPERATURE' C1064- CYLINDERS' C31 (EXCLUDING SEC. 10 1.2io SAMPLING- C172
COMPRESSION TEST RESULTS
ASTM C39; C1231
SPECIMEN TEST I TOTAL CYLINDER CYLINDER COMPRESSIVE TYPE OF BREAK.
LABORATORY IDENTIFICA TION AGE DATE OF LOAD DIAMETER AREA STRENGTH AS SHOWN IN
NUMBER OR SET NO. (DAYS) TEST ~ (LBS.) (IN.) (sa. IN) (PSI) ASTM C39
1382 A 7 07/16/08 89780 6.00 28.27 3180 Type 3
1382 B 7 07/16/08 95210 6.00 28.27 3370 Type 3
1382 C 28 08/06/08
1382 D \ 28 08/06/08
I I
I
I
I
SPECIFICATIONS
28 3000
REMARKS: K Cylinders made by PSI representative
Cylinders picked up by PSI
K representative.
Cylinders made by Architect's or
Contractor's representative
Test results comply with applicable
speCifications.
Cylinders delivered to PSI laboratory.
Test results do not comply with
appllcable specifications.
TECHNICIAN:
William Miller
cc: Hynes; Davis; Stone
Respectfully submitted,
Professional Service Industries, Inc.
THESE TEST RESULTS APPLY ONLY TO THE SPECIFIC SAMPLES TESTED AND MAY NOT BE INDICATIVE OF THE ENTIRE CONCRETE PLACEMENT
REPORTS MAY NOT BE REPROOUCED. EXCEPT IN FULL. WITHOUT WRITTEN PERMISSION BY PROFESSIONAL SERVICE INDUSTRIES. INC.
PSI A.200.4N F
Professional Service Industries, Inc.. 4087 Shilling Way. Dallas, TX 75237. Phone 214/330-9211. Fax 214/467-0031