Loading...
Chicken Express-LR080709 l."~ ;1 Information ~~. .To Build On Engineering · Consulting · ~ng REPORT OF FIELD TESTING OF CONCRETE TESTED FOR: RANDY HYNES RANDY HYNES GENERAL CONTRACTOR 101 TRINITY VIEW RD WEATHERFORD, TX 76087 PROJECT: CHICKEN EXPRESS RESTAURANT COPPELL, TX DATE: July 09, 2008 PSI REPORT NO.: 341-80040-19 FIELD DATA: Concrete was delivered by Southern Star, mix number 9351. I NO.OF CONCRETE CUBIC I TEMPERATURE, OF SPECIMENS SUPPLIER TIME TRUCK TIME TRUCK YARDS OF AIR SET NO MADE TICKET NUMBER DISPATCHED UNLOADED CONCRETE SLUMP, In CONTENT, % AIR CONCRETE I 1381 4 1308262 05:02 am 05:32 am 30.0 5 [ 4.5 79 91 I I 1382 4 1308425 07:13 07:53 120.0 5 1/4 I 4.7 78 90 I am am i I I ! I I I I I ! I I i I LOCATION: Parking Lot/Firelane 1381 30' North, 120' West from the Northwest Corner of Pad 1382 35' North, 20' West from the Southwest Corner of Pad I I NOTE: APPLICABLE ASTM STANDARDS, UNLESS OTHERWISE INDICATED: MAKING SPECIMENS: C31 (EXC. SEC 101,2): SLUMP C143: AIR CONTENT: C231IEXC, SEC. B): TEMPERATURE Cl0B4: SAMPLING: C172 REMARKS: Observed the placement of 200.0 cubic yards of concrete. TECHNICIAN: Godfrey White Respectfully submitted, Professional Service Industries, Inc. cc: Hynesj Davisj Stone THESE TEST RESULTS APPLY ONL Y TO THE SPECIFIC SAMPLES TESTED AND MAY NOT BE INDICATIVE OF THE ENTIRE CONCRETE PLACEMENT REPORTS MAY NOT BE REPRODUCED, EXCEPT IN FULL, WITHOUT WRITTEN PERMISSION BY PROFESSIONAL SERVICE INDUSTRIES, INC. PSI A-200-1 (BIF Professional Service Industries, Inc.. 4087 Shilling Way. Dallas, TX 75237. Phone 214/330-9211 . Fax 214/467-0031 l....~;l Information ~..". .To Build On Ellfllnea"'" · c...ItIng · ntsfIng .. n /,fl, 7/t"e )~g~ REPORT OF CONCRETE COMPRESSION TEST TESTED FOR: RANDY HYNES RANDY HYNES GENERAL CONTRACTOR 101 TRINITY VIEW RD WEATHERFORD, TX 76087 DATE: July 09, 2008 PSI REPORT NO.: 341-80040-20 FIELD DATA: LOCATION OF PLACEMENT PROJECT: Parking LotjFirelane 30' North, 120' West from the Northwest Corner of Pad DATE PLACED TIME SLUMP, IN. AIR CONTENT, % AIR TEMPERATURE, OF CONCRETE TEMPERATURE DATE RECEIVED IN LAB FIELD DATA SUBMITTED BY MIX DATA SUBMITTED BY July 09, 2008 05:16 am 5 4.5 79 OF 91 July 10, 2008 PSI\Godfrey White Southern Star SUPPLIER DELIVERY TICKET NO.fTRUCK NO. MIX NUMBER AND PROPORTIONS CEMENT WATER FINE AGGREGATE COARSE AGGREGATE ADMIXTURE Southern 1308262 9351 5.5 SK Star NOTE: APPLICABLE ASTM STANDARDS UNLESS OTHERWISE INDICAT~O SLUMp. C143- AIR CONTENT- C231 (EXCLUDING SEe 6)" TEMPERATURE: C1064" CYLINDERS. C31 (EXCLUDING SEe 1012)" SAMPLING. C172 COMPRESSION TEST RESULTS ASTM C39; C 1231 SPECIMEN TEST TOTAL CYLINDER CYLINDER COMPRESSIVE TYPE OF BREAK. LABORATORY IDENTIFICATION AGE DA TE OF LOAD DIAMETER AREA STRENGTH AS SHOWN IN NUMBER OR SET NO. (DAYS) TEST (LBS.) (IN.) (sa. IN.) ASTM C39 1381 A 7 07/16/08 99400 6.00 Type 2 1381 B 7 07/16/08 102750 6.00 Type 3 1381 C 28 08/06/08 1381 D 28 08/06/08 I SPECIFICATIONS 28 REMARKS: X Cylinders made by PSI representalive. Cylinders picked up by PSI K representative Cylinders made by Architect's or Contractor's representative. 3000 Test results comply with applicable specifications. Cylinders delivered to PSI laboratory. Test results do not comply with applicable specifications TECHNICIAN: William Miller cc: Hynes; Davis; Stone Respectfully submitted, Professional Service Industries, Inc. THESE TEST RESULTS APPL Y QNL Y TO THE SPECIFIC SAMPLES TESTED AND MAY NOT BE INDICATIVE OF THE ENTIRE CONCRETE PLACEMENT. REPORTS MAY NOT BE REPRODUCED. EXCEPT IN FULL. WITHOUT WRITTEN PERMISSION BY PROFESSIONAL SERVICE INDUSTRIES. INC PSI A-200-4N F Professional Service Industries, Inc.. 4087 Shilling Way. DaHas, TX 75237. Phone 214/330-9211 . Fax 214/467-0031 l- ,,~., ['!formation ~.,. .To Build On Engineering . ConsultIng · Tutlng REPORT OF CONCRETE COMPRESSION TEST TESTED FOR: RANDY HYNES RANDY HYNES GENERAL CONTRACTOR 101 TRINITY VIEW RD WEATHERFORD, TX 76087 DATE: July 09, 2008 PSI REPORT NO.: 341-80040-21 PROJECT: CHICKEN EXPRESS RESTAURANT COPPELL, TX FIELD DATA: LOCATION OF PLACEMENT Parking Lot/Firelane 35' North, 20' West from the Southwest Corner of Pad DATE PLACED TIME SLUMP, IN. AIR CONTENT, % AIR TEMPERATURE, of CONCRETE TEMPERATURE DATE RECEIVED IN LAB FIELD DATA SUBMITTED BY MIX DATA SUBMITTED BY July 09, 2008 07:38 am 5 1/4 4.7 78 of 90 July 10, 2008 PSI\Godfrey White Southern Star SUPPLIER DELIVERY TICKET NO.rrRUCK NO. MIX NUMBER AND PROPORTIONS CEMENT WATER FINE AGGREGATE COARSE AGGREGATE ADMIXTURE Southern 1308425 9351 5.5 SK Star NOTE: APPLICABLE ASTM STANDARDS UNLESS OTHERWISE INDICATED' SLUMP: C143' AIR CONTENT' C2311EXCLUDING SEC, 6)" TEMPERATURE' C1064- CYLINDERS' C31 (EXCLUDING SEC. 10 1.2io SAMPLING- C172 COMPRESSION TEST RESULTS ASTM C39; C1231 SPECIMEN TEST I TOTAL CYLINDER CYLINDER COMPRESSIVE TYPE OF BREAK. LABORATORY IDENTIFICA TION AGE DATE OF LOAD DIAMETER AREA STRENGTH AS SHOWN IN NUMBER OR SET NO. (DAYS) TEST ~ (LBS.) (IN.) (sa. IN) (PSI) ASTM C39 1382 A 7 07/16/08 89780 6.00 28.27 3180 Type 3 1382 B 7 07/16/08 95210 6.00 28.27 3370 Type 3 1382 C 28 08/06/08 1382 D \ 28 08/06/08 I I I I I SPECIFICATIONS 28 3000 REMARKS: K Cylinders made by PSI representative Cylinders picked up by PSI K representative. Cylinders made by Architect's or Contractor's representative Test results comply with applicable speCifications. Cylinders delivered to PSI laboratory. Test results do not comply with appllcable specifications. TECHNICIAN: William Miller cc: Hynes; Davis; Stone Respectfully submitted, Professional Service Industries, Inc. THESE TEST RESULTS APPLY ONLY TO THE SPECIFIC SAMPLES TESTED AND MAY NOT BE INDICATIVE OF THE ENTIRE CONCRETE PLACEMENT REPORTS MAY NOT BE REPROOUCED. EXCEPT IN FULL. WITHOUT WRITTEN PERMISSION BY PROFESSIONAL SERVICE INDUSTRIES. INC. PSI A.200.4N F Professional Service Industries, Inc.. 4087 Shilling Way. Dallas, TX 75237. Phone 214/330-9211. Fax 214/467-0031