Loading...
Chicken Express-LR080711 (2) REPORT OF CONCRETE COMPRESSION TEST -----~--~-- " /YCHICKEN EXPRESS RESTAURANT ( COPPELL, TX \ \ l-lIo S ., Informntion ~W1. .To Build On Engineering. Consulting · Testing TESTED FOR: RANDY HYNES ~~Y HYNES GENERAL CONTRP.CTOR 101 TRINITY VIEW RD WEATHERFORD, TX 76087 DATE: July 11, 2008 FIELD DATA: LOCATION OF PLACEr.;lENT PROJECT: PSI REPORT NO_: 34180040-23 -_.__...-------~---- Paving 10' into Northeast Corner of Driveway/Parking Lot DATE PLACED TIME SLUMP, IN AIR CONTENT, % AIR TEMPERATURE, of CONCRETE TEMPERATURE DATE RECEIVED IN LAB FIELD DATA SUBMITTED BY MIX DATA SUBMITTED BY July 11, 2008 09:10 am 5 1/2 3.5 89 JF 92 July 12, 2008 PSI\Randy Ihnfeldt southern Star SUPPLIER DELIVERY TICKET NO/TRUCK NO_ MIX NUMBER AND PROPORTIONS CEMENT WATER FINE AGGREGATE COARSE AGGREGATE ADMiXTURE Southern 1311112 9351 5.5 Sk Star -------------------- ~C-E APP' ICA,BLEA~~"ili&J"'hl."'&QTrER'NISE iNOICAT~D SLUMP CIA) AIR ~C~-=,- c:)LJ;:r:l.\i~~~ TE','O~RAT~.i:J]2.L::;y' :~OERS e31 '~XCLUOiNG SEC 101 :, ~AMP' ING CI72 COMPRESSION TEST RESULTS ASTM C39. C123' COMPRESSIVE STRENGTH IPS TYPE OF BREAK AS SHOWN IN ASTM C39 ~-_.._~-~---_.- , SPECIMEN ! TEST TOTAL CYLINDER 'I: CYLINDER IDENTIFICATION: AGE DATE OF LOAD DIAMETER AREA OR SET NO (DAYS)' TEST (L5S) (IN)' [SO IN) - ~.________;_~----r----------~----~-----i A 7 07/18/08 89650 6.00 '28.27 B 7 07/18/08 88210 6.00 \ 28.27 C 28 08/08/08 D 28 08/08/08 LABORATORY NUMBER 1402 1402 1402 1402 I I , I -----r~ 28 ' SPECIFICA TIONS _._---_._--'--._-------'-~---~------_._~-_.- REMARKS: ~ Cylinders made by PSI represenla"ve Cylinders made by Architect's or Contractor's representative TECHNICIPul\J : Randy Ihnfeldt C~. ~ . Hynes; Davis; Stone Type 5 Type 2 L_ _______L___-1 i 3000 _~~___.------1_~ Test results comply with acpllcaDle s;::'eclflcatlor.s. Test results do not com~ly with applicable speCifications REPORTS MAY NOT BE qEPROCUCED E<CEPT IN FJL~ '/..'\THOLJ-'- \\,qiTTEN PERMISSION B'~ ;JROFESS;O~.).,- SE~\/ICE INouSTRIES INC PS; ::'~')'J.4N F Professional Service Industries. Inc.' 4087 Shilling Way' Dallas, TX 75237' Phone 214/330-9211' Fax 214/467-0031 l....!: ., lriformation ~~. .To Build On Engineering. Consulting · Testing REPORT OF CONCRETE COMPRESSION TEST TESTED FOR: RANDY HYNES P~Y HYNES GENERAL CONTRACTOR 101 TRINITY VIEW RD WEATHERFORD, TX 76087 DATE: July 11, 2008 FIELD DATA: LOCATION OF PLACEMENT PROJECT: CHICKEN EXPRESS RESTAURANT COPPELL, TX PSI REPORT NO.: 341- 80040 -24 Paving 15' West by 50' South from Entrance of Main Road (Be1tline) DATE PLACED TIME SLUMP, IN AIR CONTENT, % AIR TEMPERATURE, of CONCRETE TEMPERATURE OF DATE RECEIVED IN LAB FIELD DATA SUBMITTED BY MIX DATA SUBMITTED BY July 11, 2008 11:20 am 5 4.0 91 93 July 12, 2008 PSI\Randy Ihnfeldt Southern Star SUPPLIER DELIVERY TICKET NOffRUCK NO. MIX NUMBER AND PROPORTIONS CEMENT WATER FINE AGGREGATE COARSE AGGREGATE ADMIXTURE Southern 1311326 9351 5.5 Sk Star _._._--~--_._-----_.----_.~_._-- tiQIE-APP.' :CABLE ASTM S~_~RDS IN,-ESS .::ThER'NISE INDICATED SL.UMP C143 AiR ('ONTENT C231 (EX'~LUD'NG SEe 61. TEMPERATL;RE C106~ CY' NO;;:RS C31 'E':\CLUOING SEe 10 t 'Jl- SAl\~PLlNG: C1?2 COMPRESSION TEST RESULTS ASTM C39; C 1231 TYPE OF BREAK, AS SHOWN IN ASTM C39 7 07/18/08 7 07/18/08 28 OS/OS/08 2S 08/08/08 I I I I : ! I I _~'~'_~_~_______'_'r_.---+-~.-----~-L__.--- .. __.___..1-_ ____.-----L...------_ I , I. 28 ____.___~__l___~ ------ --~.._..----- ,-- SPECI~EN I TEST ! L~~9,,~ET~RY 'ID6~T~~'f~~ON IDAA~~) ! D9~~iF -'~~-- I ----r-----'--- TOTAL LOAD (LBS) 68780 75740 1403 1403 1403 1403 .'A B C D SPECIFICATIONS CYLINDER DIA(~~EiE~_1 6.00 , 6.00 i CYLINDER AREA (SO IN) Type 4 Type 2 28.27 28.27 3000 J Tesl results comply with applicable specifications Cyl'nders picked up by PSI X representative Test results do not comply w'th apDlicable specifications REMARKS: ~ CI""de-s mace by PSI represenlat,ve Cylinders made by Arcrltecl's or CGrtractcrs re:::,resentat:ve Cylinders jell';ered to PSllabcratory' TECHNICIJ'..N: Randy Ihnfeldt cc: Hynes; Davis; Stone Respectfully submitted, Professional Service Industries, Inc. THESE ~EST RESUL T5 APPLY O"-L Y TO THE SPECIFIC SAMP'_::S TESTED M.D MA'{ NOT BE lNDICATl'iE OF Tr-<E ~NTIRE CONCRETE PlACE'-1ENT REPORTS MAY NOT BE ~EPROCIJCED EXCEPT IN FULL, '/,/:THQUT WRITTEN PEq'~~ISS,O~i BY PROFESSiO~AL SER'/ICE iNDUSTRIES. INC ~Sl A.;::C/).~N F Professional Service Industries, Inc. 4087 Shilling Way. Dallas, TX 75237. Phone 214/330-9211. Fax 214/467-0031 l *'!:-' lriformation ~.,. ,To Build On Engineering. Consulting · Testing REPORT OF CONCRETE COMPRESSION TEST TESTED FOR: Rh"IDY H'1'NES RANDY HYNES GENE~~L CONTRACTOR 101 TRINITY VIEW RD WEATHERFORD, TX 76087 DATE: July 11, 2008 PROJECT: CHICKEN EXPRESS RESTAURANT COPPELL, TX PSI REPORT NO.: 341-80040-25 -,~-~--~-_._.~----- FIELD DATA: LOCATION OF PLACEMENT Paving 12' North from Entrance of Driveway DATE PLACED TIME SLUMP, IN. AIR CONTENT. % AIR TEMPERATURE, of CONCRETE TEMPERATURE DATE RECEIVED IN LAB FIELD DATA SUBMITTED BY MIX DATA SUBMITTED BY July 11, 2008 01:50 pm 4 1/2 4.0 98 of 99 July 12, 2008 PSI\Randy Ihnfeldt Southern Star SUPPliER DEliVERY TICKET NO.iTRUCK NO. MIX NUMBER AND PROPORTIONS CEMENT WATER FINE AGGREGATE COARSE AGGREGATE ADMIXTURE Southern 1311615 9351 5.5 Sk Star tiQ.TE: APP~ICABLE ASTM STANDARDS UNLI'O"SS OTHER~\'!SE INDICATED SLU~lP C14J ~'JNTENT C2JlIE>(ClUOING SEe 61 TEMPl=RATURE C106.t CYLINDERS C31 ,::\'""LUDING SEC, 101 21' SAMPLING C172 COMPRESSION TEST RESULTS ASTM C39 C'23~ SPECIMEN [' TEST ':--~ TOTAL -~-r-- CYLINDER I. IDENTIFICATION AGE, DATE OF LOAD I DIAMETER OR SET NO ,(DAYS) I TEST (LBS). (IN) _~___+__~----------~--t-- - LABORATORY NUMBER 1404 1404 1404 1404 A B C D ..., I 07/18/08 07/18/08 08/08/08 08/08/08 86020 87610 7 28 28 6.00 6.00 Type 2 Type 3 TYPE OF BREAK, AS SHOWN IN ASTM C39 --~-,._----+-----..~---- -----~---_.._---_._,~- i SPECIFICATIONS i ~' I 28 -_..__._-_._-~.- ._~-- ------_._~-----~---------~. Cylinders plc~ed up by PSI X re;:,resentatl'~'e REMARKS: 2=_ Cy,nders r'1ade by PSI representative made DY Arcr'l:ect'sJr recrese'ltat've 3000 Test resL;lts comply with acp:icable spec'ficallons C"llln,j~rs del'ver'ec to PSllaborator/ Test results do not comr;iy .....I:h applicab:e speCifications TECHNICIA..T\I : Randy Ihnfeldt cc: Hynes; Davis; Stone Respectfully submitted, Professional Service Industries, Inc. TI-1ESE TEST RESUL ~s APPLY ONLY TO "'"I-lE SPE(::FI~ SAMP'~ES TESTED AND MAY \lOT BE INCICA TI\/E OF T'"1E ENTIRE CONCRE;E PLACEMErv: REPORTS ~'Ay' NOT BE REPROO\..,CEC EXCEPT iN FULL WITHOUT WR!TTE"l PER~tS.:,ICN 5'. PRC'FESS;O~.AL SER\i'CE iNDUSTRIES, :NC P'31 A-2Uu-4N F Professional Service Industries. Inc.. 4087 Shilling Way. Dallas, TX 75237 . Phone 214/330-9211 . Fax 214/467-0031