Chicken Express-LR080711 (3) l n.~ ;1 lnfonnation I:!!..:JII. .10 Build On E"9lneerlng · Consulting · Jitstl"9 PROJECT: REPORT OF CONCRETE COMPRESSION TEST TESTED FOR: L CONTRACTOR RD 76087 DATE: FIELD DATA: , LOCATION OF PLAfEMENT \ PSI REPORT NO.: Paving 10' into Northeast Corner of Driveway/Parking Lot DATE PLACED TIME SLUMP, IN. AIR CONTENT, % AIR TEMPERATURE, of CONCRETE TEMPERATURE DATE RECEIVED IN LAB FIELD DATA SUBMITTED BY MIX DATA SUBMITTED BY July 11, 2008 09:10 am 5 1/2 3.5 89 OF 92 July 12, 2008 PSI\Randy Ihnfeldt Southern Star SUPPLIER DELIVERY TICKET NOJTRUCK NO. MIX NUMBER AND PROPORTIONS CEMENT WATER FINE AGGREGATE COARSE AGGREGATE ADMIXTURE Southern 1311112 9351 5.5 Sk Star NOTE' APPLICABLE ASTM STANDARDS UNLESS OTHERWISE INDICATED- SLUMP' C143' AIR CONTENT' C231 (EXCLUDING SEe 61' TEMPERATURE' Cl0M' CYLINDERS' C31 (EXCLUDING SEe 1012\- SAMPLING- C172 COMPRESSION TEST RESULTS ASTM C39: C1231 SPECIMEN TEST TOTAL CYLINDER CYLINDER COMPRESSIVE TYPE OF BREAK, LABORATORY IDENTIFICA nON AGE DATE OF LOAD DIAMETER AREA STRENGTH AS SHOWN IN NUMBER OR SET NO. (DAYS) TEST (LBS.) (IN.) (sa. IN.) (PSI) ASTM C39 1402 A 7 07/18/08 i 89650 6.00 28.27 3170 Type 5 1402 B 7 07/18/08 88210 6.00 28.27 3120 Type 2 1402 C 28 08/08/08 115380 6.00 28.27 4080 Type 2 1402 D 28 08/08/08 115720 6.00 28.27 4090 Type 2 I I SPECIFICATIONS 28 3000 Test results comply with applicable specIfications. Cylinders made by Architect's or Contractor's representative. Cylinders picked up by PSI ~ representative. Test results do not comply with applicable specifications. REMARKS: ~ Cylinders made by PSI representative. Cylinders delivered to PSI laboratory . TECHNICIAN: Randy Ihnfeldt cc: Hynes; Davis; Stone ft)~ ully submitted, lonal Service Industries, Inc. 9/1~/?:& Professional Service Industries, Inc.. 4087 Shilling Way. Dallas, TX 75237. Phone 214/330-9211 . Fax 214/467-0031 THESE TEST RESULTS APPL Y ONLY TO THE SPECIFIC SAMPLES TESTED AND MAY NOT BE INDICATIVE OF THE ENTIRE CONCRETE PLACEMENT REPORTS MAY NOT BE REPRODUCED. EXCEPT IN FULL. WITHOUT WRITTEN PERMISSION BY PROFESSIONAL SERVICE INDUSTRIES. INC. PSI A-200-4N F l."~ il Information ~~. .To Build On Engineering. Consulting. Testing REPORT OF CONCRETE COMPRESSION TEST TESTED FOR: RANDY HYNES RANDY HYNES GENERAL CONTRACTOR 101 TRINITY VIEW RD WEATHERFORD, TX 76087 DATE: July 11, 2008 REVISION #1 PSI REPORT NO.: 341-80040-24 FIELD DATA: LOCATION OF PLACEMENT PROJECT: CHICKEN EXPRESS RESTAURANT COPPELL, TX Paving 15' West by 50' South from Entrance of Main Road (Beltline) DATE PLACED TIME SLUMP, IN. AIR CONTENT, % AIR TEMPERATURE, OF CONCRETE TEMPERATURE DATE RECEIVED IN LAB FIELD DATA SUBMITTED BY MIX DATA SUBMITTED BY July 11, 2008 11:20 am 5 4.0 91 OF 93 July 12, 2008 PSI\Randy Ihnfeldt Southern Star SUPPLIER DELIVERY TICKET NO.fTRUCK NO. MIX NUMBER AND PROPORTIONS CEMENT WATER FINE AGGREGATE COARSE AGGREGATE ADMIXTURE Southern 1311326 9351 5.5 Sk Star NOTE' APPLICABLE ASTM STANDARDS UNLESS OTHERWISE INDICATED- SLlJMP- C143- AIR CONTENT' C231 (EXCLUDING SEe 6)" TEMPERATURE' C1084' CYLINDERS' C311EXCLUDlNG SEe 1012)" SAMPLING' C172 COMPRESSION TEST RESULTS ASTM C39; C1231 SPECIMEN TEST TOTAL CYLINDER CYLINDER COMPRESSIVE TYPE OF BREAK. LABORATORY IDENTIFICATION AGE DATE OF LOAD DIAMETER AREA STRENGTH AS SHOWN IN NUMBER OR SET NO. (DAYS) TEST (LBS.) (IN.) (SQ. IN.) (PSI) ASTM C39 1403 A 7 07/18/08 68780 6.00 28.27 2430 Type 4 1403 B 7 07/18/08 75740 6.00 28.27 2680 Type 2 1403 C 28 08/08/08 112260 6.00 28.27 3970 Type 3 1403 D 28 08/08/08 115820 6.00 28.27 4100 Type 3 SPECIFICATIONS 28 3000 REMARKS: K Cylinders made by PSI representative. Cylinders picked up by PSI K representative. Cylinders made by Archltecl"s or Contractor's representative. X Test results comply with applicable specifications. Cylinders delivered to PSI laboratory. Test results do not comply with applicable specifications. TECHNICIAN: Randy Ihnfeldt cc: Hynes; Davis; Stone Respectfully submitted, Professional Service Industries, Inc. THESE TEST RESULTS APPLY ONLY TO THE SPECIFIC SAMPLES TESTED AND MAY NOT BE INDICATIVE OF THE ENTIRE CONCRETE PLACEMENT REPORTS MAY NOT BE REPRODUCED. EXCEPT IN FULL. WITHOUT WRITTEN PERMISSION BY PROFESSIONAL SERVICE INDUSTRIES. INC PSI A-20Q-.4N F Professional Service Industries, Inc.. 4087 Shilling Way. Dallas, TX 75237. Phone 214/330-9211 . Fax 214/467-0031 l-"'~;l lrifonnation ~~. .To Build On Engineering. Consulting. ntsting REPORT OF CONCRETE COMPRESSION TEST TESTED FOR: RANDY HYNES RANDY HYNES GENERAL CONTRACTOR 101 TRINITY VIEW RD WEATHERFORD, TX 76087 DATE: July 11, 2008 REVISION #1 PSI REPORT NO.: 341-80040-25 FIELD DATA: LOCATION OF PLACEMENT PROJECT: CHICKEN EXPRESS RESTAURANT COPPELL, TX Paving 12' North from Entrance of Driveway DATE PLACED TIME SLUMP, IN. AIR CONTENT, % AIR TEMPERATURE, of CONCRETE TEMPERATURE DATE RECEIVED IN LAB FIELD DATA SUBMITTED BY MIX DATA SUBMITTED BY July 11, 2008 01:50 pm 4 1/2 4.0 98 of 99 July 12, 2008 PSI\Randy Ihnfeldt Southern Star SUPPLIER DELIVERY TICKET NO./TRUCK NO. MIX NUMBER AND PROPORTIONS CEMENT WATER FINE AGGREGATE COARSE AGGREGATE ADMIXTURE Southern 1311615 9351 5.5 Sk Star NOTE- APPLICABLE ASTM STANDARDS UNLESS OTHERWISE INDICATED' SLUMP- C143' AIR CONTENT' C231 (EXCLUDING see 6\' TEMPERATURE- Cl064" CYLINDERS' C31 iEXCLUDING SEe 1012)' SAMPLING" C172 COMPRESSION TEST RESULTS ASTM C39; C1231 SPECIMEN TEST TOTAL CYLINDER CYLINDER COMPRESSIVE TYPE OF BREAK. LABORATORY IDENTIFICATION AGE DATE OF LOAD DIAMETER AREA STRENGTH AS SHOWN IN NUMBER OR SET NO. (DAYS) TEST (LBS.) (IN.) (SQ. IN.) (PSI) ASTM C39 1404 A 7 07/18/08 86020 6.00 28.27 3040 Type 2 1404 B 7 07/18/08 87610 6.00 28.27 3100 Type 3 1404 C 28 08/08/08 123270 6.00 28.27 4360 Type 2 1404 D 28 08/08/08 119040 6.00 28.27 4210 Type 3 SPECIFICATIONS 28 3000 REMARKS: 1f. Cylindets made by PSI representative. Cylindets picked up by PSI 1f. representative. Cylindets made by Architect's or Contracto~s representative. X Test results comply with applicable specifications. Cylindets delivered to PSI laboratory. Test results do not comply with applicable specifications. TECHNICIAN: Randy Ihnfeldt cc: Hynes; Davis; Stone Respectfully submitted, Professional Service Industries, Inc. THESE TEST RESULTS APPLY ONLY TO THE SPECIFIC SAMPLES TESTED AND MAY NOT BE INDICATIVE OF THE ENTIRE CONCRETE PLACEMENT REPORTS MAY NOT BE REPROOUCED, EXCEPT IN FULL. WITHOUT WRITTEN PERMISSION BY PROFESSIONAL SERVICE INDUSTRIES. INC. PSI A.20Q..4N F Professional Service Industries, Inc. . 4087 Shilling Way. Dallas. TX 75237 . Phone 214/330-9211 . Fax 214/467-0031