PROJECT:
REPORT OF CONCRETE COMPRESSION TEST
TESTED FOR:
L CONTRACTOR
RD
76087
DATE:
FIELD DATA: ,
LOCATION OF PLAfEMENT
\
PSI REPORT NO.:
Paving
10' into Northeast Corner of Driveway/Parking Lot
DATE PLACED
TIME
SLUMP, IN.
AIR CONTENT, %
AIR TEMPERATURE, of
CONCRETE TEMPERATURE
DATE RECEIVED IN LAB
FIELD DATA SUBMITTED BY
MIX DATA SUBMITTED BY
July 11, 2008
09:10 am
5 1/2
3.5
89
OF 92
July 12, 2008
PSI\Randy Ihnfeldt
Southern Star
SUPPLIER
DELIVERY TICKET NOJTRUCK NO.
MIX NUMBER AND PROPORTIONS
CEMENT
WATER
FINE AGGREGATE
COARSE AGGREGATE
ADMIXTURE
Southern
1311112
9351
5.5 Sk
Star
NOTE' APPLICABLE ASTM STANDARDS UNLESS OTHERWISE INDICATED- SLUMP' C143' AIR CONTENT' C231 (EXCLUDING SEe 61' TEMPERATURE' Cl0M' CYLINDERS' C31 (EXCLUDING SEe 1012\- SAMPLING- C172
COMPRESSION TEST RESULTS
ASTM C39: C1231
SPECIMEN TEST TOTAL CYLINDER CYLINDER COMPRESSIVE TYPE OF BREAK,
LABORATORY IDENTIFICA nON AGE DATE OF LOAD DIAMETER AREA STRENGTH AS SHOWN IN
NUMBER OR SET NO. (DAYS) TEST (LBS.) (IN.) (sa. IN.) (PSI) ASTM C39
1402 A 7 07/18/08 i 89650 6.00 28.27 3170 Type 5
1402 B 7 07/18/08 88210 6.00 28.27 3120 Type 2
1402 C 28 08/08/08 115380 6.00 28.27 4080 Type 2
1402 D 28 08/08/08 115720 6.00 28.27 4090 Type 2
I
I
SPECIFICATIONS
28 3000
Test results comply with applicable
specIfications.
Cylinders made by Architect's or
Contractor's representative.
Cylinders picked up by PSI
~ representative.
Test results do not comply with
applicable specifications.
REMARKS: ~ Cylinders made by PSI representative.
Cylinders delivered to PSI laboratory .
TECHNICIAN: Randy Ihnfeldt
cc: Hynes; Davis; Stone
ft)~
ully submitted,
lonal Service Industries, Inc.
9/1~/?:&
Professional Service Industries, Inc.. 4087 Shilling Way. Dallas, TX 75237. Phone 214/330-9211 . Fax 214/467-0031
THESE TEST RESULTS APPL Y ONLY TO THE SPECIFIC SAMPLES TESTED AND MAY NOT BE INDICATIVE OF THE ENTIRE CONCRETE PLACEMENT
REPORTS MAY NOT BE REPRODUCED. EXCEPT IN FULL. WITHOUT WRITTEN PERMISSION BY PROFESSIONAL SERVICE INDUSTRIES. INC.
PSI A-200-4N F
l."~ il Information
~~. .To Build On
Engineering. Consulting. Testing
REPORT OF CONCRETE COMPRESSION TEST
TESTED FOR:
RANDY HYNES
RANDY HYNES GENERAL CONTRACTOR
101 TRINITY VIEW RD
WEATHERFORD, TX 76087
DATE:
July 11, 2008
REVISION #1
PSI REPORT NO.: 341-80040-24
FIELD DATA:
LOCATION OF PLACEMENT
PROJECT: CHICKEN EXPRESS RESTAURANT
COPPELL, TX
Paving
15' West by 50' South from Entrance of Main Road (Beltline)
DATE PLACED
TIME
SLUMP, IN.
AIR CONTENT, %
AIR TEMPERATURE, OF
CONCRETE TEMPERATURE
DATE RECEIVED IN LAB
FIELD DATA SUBMITTED BY
MIX DATA SUBMITTED BY
July 11, 2008
11:20 am
5
4.0
91
OF 93
July 12, 2008
PSI\Randy Ihnfeldt
Southern Star
SUPPLIER
DELIVERY TICKET NO.fTRUCK NO.
MIX NUMBER AND PROPORTIONS
CEMENT
WATER
FINE AGGREGATE
COARSE AGGREGATE
ADMIXTURE
Southern
1311326
9351
5.5 Sk
Star
NOTE' APPLICABLE ASTM STANDARDS UNLESS OTHERWISE INDICATED- SLlJMP- C143- AIR CONTENT' C231 (EXCLUDING SEe 6)" TEMPERATURE' C1084' CYLINDERS' C311EXCLUDlNG SEe 1012)" SAMPLING' C172
COMPRESSION TEST RESULTS
ASTM C39; C1231
SPECIMEN TEST TOTAL CYLINDER CYLINDER COMPRESSIVE TYPE OF BREAK.
LABORATORY IDENTIFICATION AGE DATE OF LOAD DIAMETER AREA STRENGTH AS SHOWN IN
NUMBER OR SET NO. (DAYS) TEST (LBS.) (IN.) (SQ. IN.) (PSI) ASTM C39
1403 A 7 07/18/08 68780 6.00 28.27 2430 Type 4
1403 B 7 07/18/08 75740 6.00 28.27 2680 Type 2
1403 C 28 08/08/08 112260 6.00 28.27 3970 Type 3
1403 D 28 08/08/08 115820 6.00 28.27 4100 Type 3
SPECIFICATIONS
28 3000
REMARKS: K Cylinders made by PSI representative.
Cylinders picked up by PSI
K representative.
Cylinders made by Archltecl"s or
Contractor's representative.
X
Test results comply with applicable
specifications.
Cylinders delivered to PSI laboratory.
Test results do not comply with
applicable specifications.
TECHNICIAN: Randy Ihnfeldt
cc: Hynes; Davis; Stone
Respectfully submitted,
Professional Service Industries, Inc.
THESE TEST RESULTS APPLY ONLY TO THE SPECIFIC SAMPLES TESTED AND MAY NOT BE INDICATIVE OF THE ENTIRE CONCRETE PLACEMENT
REPORTS MAY NOT BE REPRODUCED. EXCEPT IN FULL. WITHOUT WRITTEN PERMISSION BY PROFESSIONAL SERVICE INDUSTRIES. INC
PSI A-20Q-.4N F
Professional Service Industries, Inc.. 4087 Shilling Way. Dallas, TX 75237. Phone 214/330-9211 . Fax 214/467-0031
l-"'~;l lrifonnation
~~. .To Build On
Engineering. Consulting. ntsting
REPORT OF CONCRETE COMPRESSION TEST
TESTED FOR:
RANDY HYNES
RANDY HYNES GENERAL CONTRACTOR
101 TRINITY VIEW RD
WEATHERFORD, TX 76087
DATE:
July 11, 2008
REVISION #1
PSI REPORT NO.: 341-80040-25
FIELD DATA:
LOCATION OF PLACEMENT
PROJECT: CHICKEN EXPRESS RESTAURANT
COPPELL, TX
Paving
12' North from Entrance of Driveway
DATE PLACED
TIME
SLUMP, IN.
AIR CONTENT, %
AIR TEMPERATURE, of
CONCRETE TEMPERATURE
DATE RECEIVED IN LAB
FIELD DATA SUBMITTED BY
MIX DATA SUBMITTED BY
July 11, 2008
01:50 pm
4 1/2
4.0
98
of 99
July 12, 2008
PSI\Randy Ihnfeldt
Southern Star
SUPPLIER
DELIVERY TICKET NO./TRUCK NO.
MIX NUMBER AND PROPORTIONS
CEMENT
WATER
FINE AGGREGATE
COARSE AGGREGATE
ADMIXTURE
Southern
1311615
9351
5.5 Sk
Star
NOTE- APPLICABLE ASTM STANDARDS UNLESS OTHERWISE INDICATED' SLUMP- C143' AIR CONTENT' C231 (EXCLUDING see 6\' TEMPERATURE- Cl064" CYLINDERS' C31 iEXCLUDING SEe 1012)' SAMPLING" C172
COMPRESSION TEST RESULTS
ASTM C39; C1231
SPECIMEN TEST TOTAL CYLINDER CYLINDER COMPRESSIVE TYPE OF BREAK.
LABORATORY IDENTIFICATION AGE DATE OF LOAD DIAMETER AREA STRENGTH AS SHOWN IN
NUMBER OR SET NO. (DAYS) TEST (LBS.) (IN.) (SQ. IN.) (PSI) ASTM C39
1404 A 7 07/18/08 86020 6.00 28.27 3040 Type 2
1404 B 7 07/18/08 87610 6.00 28.27 3100 Type 3
1404 C 28 08/08/08 123270 6.00 28.27 4360 Type 2
1404 D 28 08/08/08 119040 6.00 28.27 4210 Type 3
SPECIFICATIONS
28 3000
REMARKS: 1f. Cylindets made by PSI representative.
Cylindets picked up by PSI
1f. representative.
Cylindets made by Architect's or
Contracto~s representative.
X
Test results comply with applicable
specifications.
Cylindets delivered to PSI laboratory.
Test results do not comply with
applicable specifications.
TECHNICIAN:
Randy Ihnfeldt
cc: Hynes; Davis; Stone
Respectfully submitted,
Professional Service Industries, Inc.
THESE TEST RESULTS APPLY ONLY TO THE SPECIFIC SAMPLES TESTED AND MAY NOT BE INDICATIVE OF THE ENTIRE CONCRETE PLACEMENT
REPORTS MAY NOT BE REPROOUCED, EXCEPT IN FULL. WITHOUT WRITTEN PERMISSION BY PROFESSIONAL SERVICE INDUSTRIES. INC.
PSI A.20Q..4N F
Professional Service Industries, Inc. . 4087 Shilling Way. Dallas. TX 75237 . Phone 214/330-9211 . Fax 214/467-0031