Northlake College-LR080822 .~ KLEINFELDER ~ Bright People. Right Solutions. 2211 Century Center Blvd Ste. 101 Irving, Texas 75062 Phone: (972) 870-0808 Fax: (972) 870-0802 Report Date: 8/22/2008 ReDort To: Brenda Spinelli Dallas County.C DCCCD Bond B Suite 1015 ' Dallas, TX 87015 North Lake College, N Campus 1 Task 1 Supplier: Mix No.: Cement Type: Cement Factor (sklcy): 5 sk Max. Size Agg.(in.): Admixtures: 20% Fly Ash Date Sampled: 7/28/2008 Source of Sample: Sidewalk North side of Bldg Date Received: ";;~".I'PI~~f~j;t;~;: Ii .,;.:.:!:;q,.,?',i.\' ,j ',' Time Batched: 12:31 PM Batch Size (cy): 10 Time Sampled: 1 :03 PM Water Added (gal): Contractor: Consys Const Truck/Ticket: 26/1383338 Sampled By: Leanna Morgan Submitted By: Jonathon Mayo Curing Method: Cure Room Field Cure Temp (OF) Hi: Lo: Field Cure Time: Specified Measured Min Max Slump (in) 7,25 Slump w/plasticizer (in) Ambient Air Temperature (OF) 100 Mix Temperature (OF) 98 Air Content (%) Unit Weight (pet) Time in Truck (mins.) 32 Sam pie Number Date Tested Dimensions (Inl Area Ultimate Load Compressive Required Height (In') Fracture Type (Ibs) Strength (psll Strength (psi) Dlam. 4.00 8.00 12.57 Type 2-Cone and Split 33,970 4.00 8.00 12,57 Type 2-Cone and Split 49,680 4.00 8.00 12.57 Type 3-Columnar 49,750 Average 28 Day Strength (psi DAL 78096A DAL780968 DAL 78096C DAL780960 8/412008 8/25/2008 8/25/2008 Associated Test Methods: ASTM C 31, C 138, C 143. C 172, C 173, C 231, C 617, C 1064, C 1231 Unless prior arrangements have been made all HOLD specimens will be discarded if required strength is attained. Limitations: Pursuant to 2006 IBC Section 1704, the results presented in this report are for the exclusive use of the client and the registered design professional in responsible charge. The results apply only to the samples tested. If changes to the specifications were made and not communicated to Kleinfelder, Kleinfelder assumes no responsibility for pass/fail statements (meets/did not meet), if provided. Page 1 of 2 ~ KLEINFELDER ~ Bright People. Right Solutions. 2211 Century Center Blvd Ste. 101 Irving, Texas 75062 Phone: (972) 870-0808 Fax: (972) 870..Q802 , ~.t'':'39' Report Date: 8/22/2008 Reoort To: Brenda Spinelli Dallas County Community College DCCCD Bond Program Office S. Side 1505 S, Lamar, Suite 1015 Dallas, TX 75215 Project No.: 87015 Project: North Lake College, N Campus Task: 1 Task 1 Supplier: Mix No.: Cement Type: Southern Star 7751 20% Fly Ash ,,;,::\., O:~;r I f'-:'" '~\rll'il~._;j<,,' '''''''''''''''1' '. -"~:~~~~~::;'-~:~'i^-~-:r:t,.t~::~'~}f[~~';~-;'f".::~\"Y~~~t,~_,-',' 'c Time Batched: 12:31 PM Time Sampled: 1 :03 PM "'Jf 'j'. ;; ,_:~ . ~ Date Sampled: 7/28/2008 Source of Sample: Sidewalk North side of BJdg "--.','.." Date Received: Batch Size (ey): 10 Water Added (gal): Contractor: Consys Canst. Truck/Ticket: 26/1383338 Sampled By: Leanna Morgan Submitted By: Jonathon Mayo Curing Method: Cure Room Field Cure Temp (OF) Hi: Lo: Field Cure Time: Specified Measured Min Max Slump (in) 7.25 Slumo w/olasticizer (in) Ambient Air Temperature (OF) 100 Mix Temperature (OF) 98 Air Content (%) Unit Weiaht {pef} Time in Truck (mins.) 32 ;:'~-,: .,;- '~q. ;!; ;:~_tI;~r~~~,~~~,:'J~'" ,Ii,"";! " ,;:;:ij':..!.'I,' '. Remarks: Cc: Eric Stanaland Andy Munoz James Williams Andrea Stogner Jennifer Blount Larry Davis Lee Stone Janice Webb Pete Lara Reviewed on 8/22/2008 by: ~ (" ~...--... Thomas Fe'9",on . // Project Manager Associated Test Methods: ASTM C 31, C 138, C 143, C 172, C 173, C 231, C617, C 1064, C 1231 Unless prior arrangements have been made all HOLD specimens will be discarded if required strength is attained. UmitatiDns: Pursuant tD 2006 IBC SectiDn 1704, the results presented in this repDrt are fDr the exclusive use of the client and the registered design ~rofessional in responsible charge. The results apply only to the samples tested. If changes to the specifications were made and not communicated tD I(leinfelder, KleinfeJder assumes nD responsibility for pass/fail statements (meets/did not meet), if provided. Page 2 of2