Loading...
ST9905-LR080611 CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94081124.0023 Service Date: May 13, 2008 lrerracan 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630-1010 Batch Time: 8:30am Plant: 111 Supplier: Southern Star Truck No: 103 Ticket No: 1264874 Mix I.D. No.: 9339 Water Added Onsite Before Test: 5 Gallons Water Added Onslte After Test: 0 Gallons Report Date: June 11, 2008 Project: Bethel Road I . #ST 99-05 Roadway & Drainage Improvements City Limit Line to Freeport Parkway Coppell. TX Project No.: 94081124 SamDle Information Date Cast: May 13, 2008 Time: 9:25am Sampled by: Kevin R. Hendricks Weather Conditions: Cloudy, breezy, light miSt Accumulative Yards: 6 Batch Size (cy): 6.00 Placement Method: Direct Discharge Sample Locations: Sta. 66+15 Placement Location: Median East side of Freeport Parkway Client: City of Coppell TX AUn: Rick O'Dell Engineering Dept PO Box 9478 Coppell TX 75019 Material Information Specified Strength: 3000 psi @ 28 Days Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature, of: Ambient Temperature, of: Plastic Unit Weight, pcf: Result 4.00 4.6 80 72 142.9 Specification Test Method ASTM C143 ASTM C231 ASTM C1064 ASTM C1064 ASTM C138 Laboratory Test Data Age at Maximum Compressive Date Test Load Strength Tested (days) (Ibs) (psi) OS/20/2008 7 98,480 3,480 06/10/2008 28 126,810 4,480 06/10/2008 28 126,780 4.480 Average (28 Days) 4,480 Services _ Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Set No. 1 1 1 Specimen 10 1 2 3 Diameter Area (inches) (sq. inches) 6.00 28.27 6.00 28.27 6.00 28.27 Report Distribution: (1) Cily of Coppell TX (1) Tiseo Paving Company Reviewed by: Terracon Rep: Kevin R. Hendricks rlc J. Cle eland, P.E. Senior Proj ct Engineer The tests were performed In general accordance with applicable ASTM, AASHTO, or DOT test methods. This report Is exclusively for the use of the client. indicated abcve and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the Iocatlon(s) referenced and are not necessarily Indicative of the properties of other apparently similar or Identical materials. . Page 1 of 1 01-MWB1RC11-f1.&n KlV