Loading...
ST9905-LR080502 CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94081124.0002 Service Date: April 23, 2008 lrerracon 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630-1010 Batch Time: 1 :28pm Plant: 3 Supplier: Lattimore Materials Truck No: 5023 Ticket No: 3247749 Mix I.D. No.: 1701 Water Added Onsite Before Test: 0 Gallons Water Added Onsite After Test: 0 Gallons Report Date: May 02, 2008 Project: Bethel Road I - #ST 99-05 Roadway & Drainage Improvements City Limit Line to Freeport Parkway Coppell, TX Project No.: 94081124 Sample Information Date Cast: April 23, 2008 Time: 2:21 pm Sampled by: Christopher W. Eubanks Weather Conditions: Cloudy Accumulative Yards: 10 Batch Size (cy): 10.00 Placement Method: Crane & Bucket Sample Locations: Two South Walls at Sta. 4+48 to 4+86 Placement Location: Culvert Walls at Sta. 4+48 to 4+86 and Footing at Sta. 4+10 to 4+48 Client: City of Coppell TX Attn: Rick O'Dell Engineering Dept PO Box 9478 Coppell TX 75019 Material Information Specified Strength: 3600 psi @ 28 Days Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature, of: Ambient Temperature, of: Plastic Unit Weight, pet: Result 5.00 3.0 83 80 146.8 Specification Test Method ASTM C143 ASTM C231 ASTM C 1 064 ASTM C 1 064 ASTM C138 Laboratory Test Data Age at Set Specimen Diameter Area Date Test No. 10 (inches) (sq. inches) Tested (days) 1 1 6.00 28.27 04/30/2008 7 1 2 OS/21/2008 28 1 3 OS/21/2008 28 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Maximum Compressive Load Strength (Ibs) (psi) 107,610 3,810 Terracon Rep: Christopher W. Eubanks Started: 1330 Report Distribution: (1) City of Coppell TX Reviewed by: Eric . Clev land, P.E. Senior Project Engineer The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1 01-MWB/R01.FuIUft Key CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94081124.0001 Service Date: April 22, 2008 lrerracon 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630-1010 Client: City of Coppell TX Attn: Rick O'Dell Engineering Dept PO Box 9478 Coppell TX 75019 Material Information Specified Strength: 4000 psi @ 28 Days Report Date: May 02, 2008 Project: Bethel Road I - #ST 99-05 Roadway & Drainage Improvements City Limit Line to Freeport Parkway Coppell, TX Project No.: 94081124 Sample Information Date Cast: April 22, 2008 Time: 1 :36pm Sampled by: Gregory L. Warren Weather Conditions: Clear Accumulative Yards: 10 Batch Size (cy): 10.00 Placement Method: Direct Discharge Sample Locations: Sta. 17+50 Placement Location: Box Culvert Top Sta. 17+50 to 18+50 Batch Time: 12:55pm Plant: 7 Supplier: Lattimore Materials Truck No: 959 Ticket No: 7191356 Mix 1.0. No.: 1851 Water Added Onsite Before Test 10 Gallons Water Added Onsite After Test 0 Gallons Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature, of: Ambient Temperature, of: Plastic Unit Weight, pcf: Result 4.00 2.5 86 87 151.2 Specification Test Method ASTM C143 ASTM C231 ASTM C 1 064 ASTM C 1 064 ASTM C138 Laboratory Test Data Age at Set Specimen Diameter Area Date Test No. ID (inches) (sq. inches) Tested (days) 1 1 6.00 28.27 04/29/2008 7 1 2 OS/20/2008 28 1 3 OS/20/2008 28 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Maximum Compressive Load Strength (Ibs) (psi) 99,550 3,520 Terracon Rep: Gregory L. Warren Started: 1200 1630 Report Distribution: (1) City of Coppell TX Reviewed by: ric . leveland, P.E. Senior Project Engineer The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1 01.MWBJR01-FlJlure Key CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94081124.0003 Service Date: April 22, 2008 lrerracon 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630-1010 Batch Time: 1 :56pm Plant: 125 Supplier: Southern Star Truck No: 9031 Ticket No: 1249487 Mix I.D. No.: D9339 Water Added Onsite Before Test: 0 Gallons Water Added Onsite After Test: 0 Gallons Report Date: May 02, 2008 Project: Bethel Road I - #ST 99-05 Roadway & Drainage Improvements City Limit Line to Freeport Parkway Coppell, TX Project No.: 94081124 Sample Information Date Cast: April 22, 2008 Time: 2:43pm Sampled by: Gregory L. Warren Weather Conditions: Clear Accumulative Yards: 9 Batch Size (cy): 9.00 Placement Method: Direct Discharge Sample Locations: Sta. 66+25 Placement Location: Sidewalk, East bound Sta. 65+50 to 66+60 Client: City of Coppell TX Attn: Rick O'Dell Engineering Dept PO Box 9478 Coppell TX 75019 Material Information Specified Strength: 3000 psi @ 28 Days Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature, of: Ambient Temperature, of: Plastic Unit Weight, pcf: Result 4.50 4.1 89 90 144.4 Specification Test Method ASTM C143 ASTM C231 ASTM C 1064 ASTM C 1064 ASTM C138 Laboratory Test Data Age at Set Specimen Diameter Area Date Test No. ID (inches) (sq. inches) Tested (days) 1 1 6.00 28.27 04/29/2008 7 1 2 OS/20/2008 28 1 3 OS/20/2008 28 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Maximum Compressive Load Strength (Ibs) (psi) 67,950 2,400 Terracon Rep: Gregory L. Warren Report Distribution: (1) City of Coppell TX Reviewed by: ric J. C veland, P.E. Senior roject Engineer The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1 OI.MWB/R01-Ful.ure Key