Loading...
ST9905-LR070518 Ma,-18-2007 15:11 From- 9723920102 T-480 P 002/003 F-079 ! -':'~=,=-,,~=:-~ Fes Tnas, L LP 495(' Keller Spnng> Roild, Suite 4.1;1' AJd,>on, TX 75(;01 (972) 392-3222 (FAX) 392-0\02 CO~CRETE, GROUT, AND ?vl0RTAR TESTS LErrER OF l'RA~SM1TTAL ._-~,:-_~-:--.~.~ :::_=-=~':-::r'~;:\:.'<<! TO: City of Coppell P.O. Box 9478 DATE; 0511 8/2007 RE: Bethel Road - Coppel1 Coppell, IX 75019 A TfN: Mr, Rick O'Deil PERMIT #: JOB ~~O_: 005061 LOCATION: Bethel Road, Coppell, TX V./e are enclosing: X Attached X For Your Use x ~1aterials El1gineering Division Concrete Reports: 14 x As Requested cc: TISEO Paving - Robert Caudill (---'\ -~/' ~~~ ~<~~~/ ~,~:9?"~, ---- Daniel Franklin. P,E, President /Principal Engineer ~./'f~~'//;)>~~",{y;:,O'.. ,,_,_ JasQ;1(fie~:fEi'=----~ ., ""JZ~",.c .'.- Construction Services Manager By: 'f,a}-18-2007 15:" From- 9723920102 T-480 P 003/003 F-079 Eee; Tc)(as, :"LP 4950 Kell~r Spnl1Ss Road, Suite .\80 Addl,on, TX 75001 (971) 392.3222 ~,..;..'..,.:..,::.; (FAX) 392.f)j02 ~~~i!?Z;4.-~ ConCf'ete Cylinders Strength Report Project: Locatl0n: Bethel Road - C oppell Bethel Road, Correll, IX City of Coppell - Rick O'Dell Project: 5061 Cast Date: Design Strength: Report )Jo.: Set DesigmHion: A 04/19/2007 3600 psi 14 Owner' Arch.: SlwC. Eng.: Placement Location: Footing. East Side, Sta. 42+75 Client: City of Coppell - Kenneth M. Griffin, Gen. Contr.: Cone. Contr.: Concrete Supplier: Mix Designation: Added Water: Truck No: Mix Strength: 3600 psi Time Added: Ticket No: Batch Time: Unit Wt.: FIELD TEST DATA: Tested b): [DROPOFF] Temperature - Air: Time Sampled: Concrete: Slump: Air Content: Sample Test Test Type Dlflmeter Area Breaking Compr. Brk I Break Revie\v No Date Age Cure In. In.:: Load,lbs Str.,psi Typ i by by 3}769 04/26/2007 7 l.ab 600 1827 86420 I JBAI 3060 I I 33770 05/17/2007 28 l.ab 600 28.27 I 153926 5440 1 I JBAl i 33/'71 05117,/2007 28 lAlb 6.00 28.27 152768 5400 I JB.-\ 1 1 3~T"'} ~p :"'alJ 6 00 2827 j, ,- Sarr.phng In accordance WIth (lawl ASn.~ L 172. e,.:"pllhat samp.es may have bee1 tMen from the ~eQ,nnlr.J ef the load after a mll1lffiUm dlsc~arge 01 ~pp(O;(t:l1altIY one eoDle yard (';yl'nd@,' l11old'n9 ana laboratory cunng law AST~v\ CJ ~, c~mor".s:ve sU'~n91J'\ test aNI break lyP& iaw AST~ C39. s'ump law C143. air conl91t law ASTM C 173 [V) 0' C231 (P) lemperatu'e iaw ASn~ C106~ 3ml nit \',e'ght ';'!Vi I\STM C' 3E. Cyl.njerS Jre tesllld 'Js'ng >J1bonded caps iaw A5TM C'. 231 Cr are capped L:s;ng S~lpnJr :nonar law (6: 7 Bre~k Typs. are claSSified as' ~ype 1. 2. 3, 4 5, or 6 'aw C39.04a frETT) CURING CONDlTIO'NS: Curing Box Insulated X ~o Curing Box Heatc::d Remarks: Contractor Made Cylinders Cooled Caps Ice Other (-~I~:;::7 ./ ._--;7"'--~~ \.... /"" / -- . . c:../ ~ ..?>~~..... ?; Fmal ReVIew By: ._.._.___.....n' .-- JBAl Print Date: 05/18/2007