ST9905-LR070422
ECS Texas, LLP
~.... 4950KeU... Springs Rold, Suite 480
Addison, TX 7500 I
(972)392-3222
(FAX) 392-0102
CONCRETE, GROUT, AND MORTAR TESTS
LETTER OF TRANSMITTAL
1'IDCM
TO: City ofCoppell
P.O. Box 9478
DA TE: 04/22/2008
RE: Bethel Road - Coppell
Coppell, TX 75019
A TTN: Ms. Carol Dye
PERMIT #:
JOB NO.: 005061
LOCA TION:
Bethe] Road, Coppell, TX
We are enclosing:
X Attached
.l For Your Use
x
Materials Engineering Division Concrete Reports:
]29, 147
x
As Requested
CC: TISEO Paving - Robert Caudill
City of Coppell - Rick O'Dell
By:
David A. Lewis, P.E.
Principal Engineer
Eric L. Branch, C.E.T.
Project Manager
Project:
Location:
Bethel Road - Coppell
Bethel Road, Coppell, TX
Concrete Cylinders Strength Report
Project: 5061 Set Designation: A
Cast Date: 03/25/2008
Design Strength: 3500 psi
Report No.: 129
- ECS T exa;. LLP
ms::. . 4950 Keller Springs Road. Suite 480
Addison. TX 7500 I
(972) 392-3222
,_ (FAX)392-0102
Owner: City ofCoppell- Carol Dye
Arch.:
Struc. Eng.:
Client: City of Coppell - Kenneth M Griffm,
Gen. Contr.:
Cone. Contr.:
Placement Location: Box culvert floor slab, 51 +00 to 52+00, sampled at approximatly 51 +90
Concrete Supplier: LMC
Mix Designation: 1701
Added Water:
Truck No: 50220
Mix Strength: 3600 psi
Time Added:
Ticket No: 3426153
Batch Time: 01 :25PM
Unit Wt.:
FIEI.f) TEST OA TA' Tested by:Jonathan E. Steiner
Temperature - Air: 700 F
Time Sampled:02:33PM
Concrete: 770 F
Slump: 5.00 in.
Air Content: 1.60 % (P)
Sample Test Test Type Diameter Area Breaking Compr. Brk Break Review
No Date Age Cure In. In.' Load,lbs Str.,psi Typ by by
39712 04/01/2008 7 Lab 4.00 1256 48288 3840 ELBI
39713 04/01/2008 7 Lab 4.00 1256 50]44 3990 ELBI
39714 04/22/2008 28 Lab 4.00 1256 65536 5220 4 ELBI
39715 04/22/2008 28 Lab 4.00 1256 63200 5030 4 ELB1
39716 04/22/2008 28 Lab 4.00 12.56 66080 5260 4 ELBI
39717 OS/20/2008 56 Lab 4.00 12.56
;., .. n ao:ordanoewlh iaw ASTM C172 exoe lthatsa es ma haw been taken from the be nnn of the bad aflera miliTtJm discha eofa roxinale oneOJbk: rd.
Il'Il 9 ( ) . P Il'Il Y 9 9 rg pp ~ ya
Cyt1der mo~ng and IaboraloryoJl'ng iaw ASTM C31.coll'llressile strenglhtestand break type iaw ASTM C39.Wll'll iaw C 143.ar contenliaw ASTM Cll3 M or C231 (P).
lell'lleralureiaw ASTM C1064.andunl we~ht iaw ASTM C138. Cyt1ders are tested usilg unbondeltapsiaw ASTM C12310r are capped usilg su\Jhur
mortariaw C617. Break Twesare c1assiied as: Type 1, 2,3,4.5. or6 iawC39-04a
FIELD CURING CONDITIONS:
Curing Box Insulated
X No Curing Box Heated
Remarks: (air content less than project
specifications)
Cooled
X Caps
Ice
Other
Final Review By:
ELBI
Print Date:
04/22/2008
ECS Texlli, LLP
4950 Keller Springs Road, Suite 480
Addison, TX 75001
(972) 392-3222
(FAX) 392-0102
Concrete Cylinders Strength Report
Project: 5061 Set Designation: A
Cast Date: 04/15/2008
Design Strength: 4000 psi
Report No.: 147
Project:
Location:
Bethel Road - Coppell
Bethel Road, Coppell, TX
Owner: City ofCoppell- Carol Dye
Arch.:
Struc. Eng.:
Client: City of Coppell - Kenneth M. Griffin,
Gen. Contr.:
Cone. Contr.:
Placement Location: Stamped concrete at Bethel and Freeport, Southbound side of Freeport on Southern side of
intersection.
Concrete Supplier: Southern Star
Mix Designation: 9363
Added Water: 10 Gals.
Truck No: 86
Mix Strength: 4000 psi
Time Added: 1O:20A
Ticket No: 1243448
Batch Time: 09:50AM
Unit Wt.:
FJELD TEST DATA' Tested by:Michael J. Cochran
Temperature - Air: 750 F
Time Sampled: 10:30AM
Concrete: 820 F
Slump: 3,25 in.
Air Content: 2.20 % (P)
Sample Test Test Type Diameter Area Breaking Compr. Brk Break Review
No Date Age Cure In. In.' Load,lbs Str.,psi Typ by by
40058 04/18/2008 3 Lab 4.00 12.56 56096 4460 6 ELBI
40059 04/22/2008 7 Lab 4.00 12.56 64288 5120 3 ELBI
40060 05/13/2008 28 Lab 4.00 12.56
40061 05/13/2008 28 Lab 4.00 12.56
40062 05/13/2008 28 Lab 4.00 12.56
40063 06/10/2008 56 Lab 4.00 ]2.56
Sar .. ~ aocordancewlh iaw ASTM C172,exce tthalsa lesma hawbeenlakenlmmthebe ~n~ oflhekladaftera minim discha eol a mxinate onero be rd.
I1ll 9 ( ) P I1ll Y 9 9 rg PP ~ ya
Cytlder mol:l~g and Iaboraloryroli1g iaw ASfM C31, OOl1llressMi stre nglh test and break type iaw ASTM C39,s~11ll iaw C143,ar oontentiawASTM C173 M or C231(P),
tel1lleraturaiaw ASfM C1064,andunl weghtiaw ASTM C138. Cytlders are tested usilg unbondea:apsiaw ASTM C12310r are capped usilg su\)hur
mortariaw C617. Break Typesare c1asslied a~Type 1, 2,3, 4,5, or6 iawC39-04a
FIELD CURING CONDITIONS:
Curing Box Insulated
X No Curing Box Heated
Remarks: A ir content is below project
specifications. Mr. O'Dell called for
3-day breaks after the cylinders had
Cooled
X Caps
Ice
Other
Final Review By:
ELBI
Print Date:
04/22/2008
.... ECS Texas. LLP
gs:. . ... 4950 Keller Springs Road, Suite 480
Addison, TX 75001
(972) 392-3222
(FAX) 392-0102
T'I!XA8
LETTER OF TRANSMITTAL
April 22, 2008
RE: Bethel Road - Coppell
City of Coppell
P.O. Box 9478
Coppell, TX 75019
ECS Job # 19:5061
Permits:
A TTN: Ms. Carol Dye
Location: Bethel Road
Coppell, TX
We are enclosing:
~ Materials Engineering Division Reports
~ For your use
~ As requested
CC: TISEO Paving - Robert Caudill
City of Coppell - Rick O'Dell
ENCL:
Field Report # 172
04/16/2008
IJuk~
David A. LeWIS, P. .
Principal Engineer
/~c~.
Eric L. Branch, C.E.T.
Project Manager
TN ECS Texas. LLP
gs:... ....... .... 4950 Keller Springs Road,Suite480
Addison, TX 75001
P (972) 392-3222
(FAX) 392-0102
FIELD REPORT
TII!!XA8
Project No. 19:5061
Report No. 172
Day & Date Wednesday 04/16/2008
Weather
On-Site Time 3.00
Lab Time 0.00
Travel Time* 1.00
Total 4.00
Re Obs. Time 0.00
Project Bethel Road - Coppell
Location Coppell, TX
Client City of Coppell - Carol Dye
Remarks
Trip Charges*
Chargeable Items
18.00
Tolls/Parking*
Mileage*
Time of Arrival Departure
01:30P 04:30P
* Travel time and mileage will be billed in accordance with the contract.
Summary of Services Performed (field test data, locations, elevations & depths are estimates) & Individuals Contacted.
Concrete Observation:
The undersigned arrived on site, as requested, to observe the placement of 60 cubic yards
of 3600 psi concrete for box culvert foundation.
Prior to concrete placement, Reinforcing Steel was observed and appeared to be in
accordance with project drawings and specifications.
Required test limits were: slump, 4-6 inches; air content, 3-5%, batch to placement time,
<90 minutes; and concrete temperature range, 50-90 degrees Fahrenheit.
Concrete observed on this date appeared to be placed in compliance with project
specifications with regard to temperature, slump and batch to placement time, unless noted
otherwise. Air content was below the project specifications.
1 set of 6 cylinders was cast for compressive strength.
By Jonathan E. Steiner, - Field Technician
1800
94848
.. ECS Texas, LLP
E .. 4950 Keller Springs Road, Suite 480
. Addison, TX 7500]
(972) 392-3222
(FAX) 392-0102
CONCRETE, GROUT, AND MORTAR TESTS
LETTER OF TRANSMITTAL
TI!XA8
TO: City ofCoppell
P.O. Box 9478
DATE: 04/22/2008
RE: Bethel Road - Coppell
Coppell, TX 75019
ATTN: Ms. Carol Dye
PERMIT #:
JOB NO.: 005061
LOCATION:
Bethel Road, Coppell, TX
We are enclosing:
X Attached
Materials Engineering Division Concrete Reports:
145, 146, 147
X
X
For Your Use
X
As Requested
CC: TISEO Paving - Robert Caudill
City of Coppell - Rick O'Dell
Pa/ cZ.L. ".
~id A. Lewis, P.E
Principal Engineer
~ (jk~
Eric L. Branch, C.E.T.
Project Manager
By:
~ ECS Texas, LLP
gs:. 4950 Keller Springs Road, Suite 480
Addison, TX 75001
(972) 392-3222
(FAX) 392-0102
Concrete Cylinders Strength Report
-~
Project:
Location:
Bethel Road - Coppell
Bethel Road, Coppell, TX
Project: 5061
Cast Date:
Design Strength:
Report No.:
Set Designation: A
04/11/2008
4500 psi
145
Owner: City of Coppell - Carol Dye Client: City of Coppell - Kenneth M. Griffin,
Arch.: Gen. Contr.:
Struc. Eng.: Conc. Contr.:
Placement Location: Paving, Bethel Road and Freeport Parkway, 60'E X 20'N of manhole cover
Concrete Supplier: Tarrant Concrete Co., Inc.
Mix Designation: 2478H
Added Water: 10 Gals.
Truck No: 0
Mix Strength: 4500 psi
Time Added: 02:42PM
Ticket No:
Batch Time: 02:08PM
Unit Wt.:
FIELD TEST DATA: Tested by: David M. Ellison
Temperature - Air: 780 F
Time Sampled:02:47PM
Concrete: 780 F
Slump: 5.00 in.
Air Content:5.1 0 % (P)
Sample Test Test Type Diameter Area Breaking Compr. Brk Break Review
No Date Age Cure In. In.2 Load,lbs Str.,psi Typ by by
39930 04/14/2008 3 Lab 4.00 12.56 41120 3270 3 ELBl
39931 04/18/2008 7 Lab 4.00 12.56 50400 4010 3 ELBl
39932 04/18/2008 7 Lab 4.00 12.56 57376 4570 3 ELBl
39933 05/09/2008 28 Lab 4.00 12.56
39934 05/09/2008 28 Lab 4.00 12.56
39935 05/09/2008 28 Lab 4.00 12.56
39936 06/06/2008 56 Lab 4.00 12.56
. . . .
Sampling in accordance with (iaw) ASTM Cl72, except that samples may have been taken from the beginning of the load after a minimum discharge of approximately one cubiC yard.
Cylinder molding and laboratory curing iaw ASTM C31, compressive strength test and break type iaw ASTM C39, slump iaw C143, air content iaw ASTM C173 (V) or C231 (P),
temperature iaw ASTM C1064, and unit weight iaw ASTM C138. Cylinders are tested using unbonded caps iaw ASTM C1231 or are capped using sulphur
mortar iaw C617. Break Types are classified as: Type 1, 2, 3, 4, 5, or 6 iaw C39-04a
FIELD CURING CONDITIONS:
Curing Box
X No Curing Box
Remarks:
Insulated
Heated
Cooled
X Caps
Ice
Other
Final Review By:
ELBl
Print Date:
04/22/2008
~ EeS Texas, LLP
~ 4950 Keller Springs Road, Suite 480
Addison, TX 7500]
(972) 392-3222
(FAX) 392-0 I 02
Concrete Cylinders Strength Report
Project:
Location:
Bethel Road - Coppell
Bethel Road, Coppell, TX
Project: 5061
Cast Date:
Design Strength:
Report No.:
Set Designation: A
04/12/2008
4500 psi
146
Owner: City ofCoppell - Carol Dye
Arch.:
Struc. Eng.:
Client: City of Coppell - Kenneth M. Griffin,
Gen. Contr.:
Conc. Contr.:
Placement Location: Paving, SW corner of Bethel and Freeport, 50'N X 25'E of manhole cover
Concrete Supplier: Tiseo Paving Company
Mix Designation: 2488H
Added Water:
Truck No:
Mix Strength: 4500 pSI
Time Added:
Ticket No:
Batch Time: 07:06AM
Unit Wt.:
FIELD TEST DATA: Tested by: David M. Ellison
Temperature - Air: 520 F
Time Sampled:08:00AM
Concrete: 720 F
Slump:4.50 in.
Air Content:4.30 % (P)
Sample Test Test Type Diameter Area Breaking Compr. Brk Break Review
No Date Age Cure In. In.2 Load,lbs Str.,psi Typ by by
39937 04/] 5/2008 3 Lab 4.00 ]2.56 48640 3870 ELBl
39938 04/] 9/2008 7 Lab 4.00 ] 2.56 61920 4930 3 ELB]
39939 04/] 9/2008 7 Lab 4.00 12.56 61312 4880 3 ELBl
39940 05/] 0/2008 28 Lab 4.00 12.56
39941 05/] 0/2008 28 Lab 4.00 12.56
39942 05/10/2008 28 Lab 4.00 12.56
39943 06/07/2008 56 Lab 4.00 12.56
. . . .
Sampling In accordance With (law) ASTM C172, except that samples may have been taken from the beginning of the load after a minimum discharge of approximately one cubiC yard.
Cylinder molding and laboratory curing iaw ASTM C31, compressive strength test and break type iaw ASTM C39, slump iaw C143, air content iaw ASTM C173 (V) or C231 (P),
temperature iaw ASTM C1064, and unit weight iaw ASTM C138. Cylinders are tested using un bonded caps iaw ASTM C1231 or are capped using sulphur
mortar iaw C617. Break Types are classified as: Type 1, 2, 3, 4, 5, or 6 law C39-04a
FIELD CURING CONDITIONS:
Curing Box
X No Curing Box
Remarks:
Insulated
Heated
Cooled
X Caps
Ice
Other
Final Review By:
ELBl
Print Date:
04/22/2008
~ ECS Texas, LLP
~. 4950 Keller Springs Road, Suite 480
Addison, TX 75001
(972) 392-3222
(FAX) 392-0102
Concrete Cylinders Strength Report
_TIIXAS
Project:
Location:
Bethel Road - Coppell
Bethel Road, Coppell, TX
Project: 5061
Cast Date:
Design Strength:
Report No.:
Set Designation: A
04/15/2008
4000 psi
147
Owner: City of Coppell - Carol Dye Client: City of Coppell - Kenneth M. Griffin,
Arch.: Gen. Contr.:
Struc. Eng.: Conc. Contr.:
Placement Location: Stamped concrete at Bethel and Freeport, Southbound side of Freeport on Southern side of
intersection.
Concrete Supplier: Southern Star
Mix Designation: 9363
Added Water: 10 Gals.
Truck No: 86
Mix Strength: 4000 psi
Time Added: 10:20A
Ticket No: 1243448
Batch Time: 09:50AM
Unit Wt.:
FIELD TEST DATA: Tested by: Michael J. Cochran
Temperature - Air: 750 F
Time Sampled:l0:30AM
Concrete: 820 F
Slump:3.25 in.
Air Content:2.20 % (P)
Sample Test Test Type Diameter Area Breaking Compr. Brk Break Review
No Date Age Cure In. In.2 Load,lbs Str.,psi Typ by by
40058 04/18/2008 3 Lab 4.00 12.56 56096 4460 6 ELBl
40059 04/22/2008 7 Lab 4.00 12.56
40060 05/13/2008 28 Lab 4.00 12.56
40061 05/13/2008 28 Lab 4.00 12.56
40062 05/13/2008 28 Lab 4.00 12.56
40063 06/1 0/2008 56 Lab 4.00 12.56
. . . .
Sampling In accordance With (law) ASTM C172, except that samples may have been taken from the beginning of the load after a minimum discharge of approximately one cubic yard.
Cylinder molding and laboratory curing iaw ASTM C31, compressive strength test and break type iaw ASTM C39, slump iaw C143, air content iaw ASTM C173 (V) or C231 (P),
temperature iaw ASTM C1064, and unit weight iaw ASTM C138. Cylinders are tested using unbonded caps iaw ASTM C1231 or are capped using sulphur
mortar iaw C617. Break Types are classified as: Type 1, 2, 3, 4, 5, or 6 iaw C39-04a
FIELD CURING CONDITIONS:
Curing Box Insulated
X No Curing Box Heated
Remarks: Mr. O'Dell called for 3-day breaks
after the cylinders had been loaded
into concrete system. In order to
Cooled
X Caps
Ice
Other
Final Review By:
ELBl
Print Date: