Loading...
ST9905-LR070404 '" ECS Texas, LLP E. . 4950 Keller Springs Road, Suite 480 Addison, TX 7500] (972) 392-3222 (FAX) 392-0102 CONCRETE, GROUT, AND MORTAR TESTS LETTER OF TRANSMITTAL TII!XAS TO: City of Coppell P,O. Box 9478 DA TE: 04/04/2008 RE: Bethel Road - Coppell Coppell, TX 75019 A TTN: Ms. Carol Dye PERMIT #: JOB NO.: 005061 LOCATION: Bethel Road, Coppell, TX We are enclosing: X Attached Materials Engineering Division Concrete Reports: 131 X X For Your Use X As Requested CC: TISEO Paving - Robert Caudill City of Coppell - Rick O'Dell ~Lf:~: Principal Engineer ~3~ Eric L. Branch, C.E.T. Project Manager By: Project: Location: Bethel Road - Coppell Bethel Road, Coppell, TX Concrete Cylinders Strength Report Project: 5061 Set Designation: A Cast Date: 03/27/2008 Design Strength: 3500 psi Report No.: 131 ~ ECS Texas, LLP ~ 4950 Keller Springs Road, Suite 480 Addison, TX 75001 (972) 392-3222 (FAX) 392-0102 TlIXA8 Owner: City ofCoppell- Carol Dye Arch.: Struc. Eng.: Client: City of Coppell - Kenneth M. Griffin, Gen. Contr.: Cone. Contr.: Placement Location: South Box culvert walls, 51 +00 to 52+00, sampled at South most wall Concrete Supplier: LMC Mix Designation: 1701 Added Water: Truck No: 890 Mix Strength: 3600 pSI Time Added: Ticket No: 3642689 Batch Time: 01 :38PM Unit Wt.: FIELD TEST DATA: Tested by: Jonathan E. Steiner Temperature - Air: 700 F Time Sampled:02:23PM Concrete: 770 F Slump:4.00 in. Air Content:1.90 % (P) Sample Test Test Type Diameter Area Breaking Compr. Brk Break Review No Date Age Cure In. In.2 Load,lbs Str.,psi Typ by by 39724 04/03/2008 7 Lab 4.00 12.56 52224 4160 ELBl 39725 04/03/2008 7 Lab 4.00 12.56 52864 4210 ELBl 39726 04/24/2008 28 Lab 4.00 12.56 39727 04/24/2008 28 Lab 4.00 12.56 39728 04/24/2008 28 Lab 4.00 12.56 39729 OS/22/2008 56 Lab 4.00 12.56 Sampling In accordance with (iaw) ASTM C172, except that samples may have been taken from the beginning of the load after a minimum discharge of approximately one cubic yard. Cylinder molding and laboratory curing iaw ASTM C31, compressive strength test and break type iaw ASTM C39, slump iaw C143, air content iaw ASTM C173 M or C231 (P), temperature iaw ASTM C1064, and unit weight iaw ASTM C138. Cylinders are tested using unbonded caps iaw ASTM C1231 or are capped using sulphur mortar iaw C617. Break Types are classified as: Type 1, 2, 3, 4, 5, or 6 iaw C39-04a FIELD CURING CONDITIONS: Curing Box Insulated X No Curing Box Heated Remarks: Culvurt walls 100 ft east from northwestern comer of Minyards Air content below specifications Cooled X Caps Ice Other Final Review By: ELBl Print Date: 04/04/2008 '" ECS Texas. LLP E 4950 Keller Springs Road, Suite 480 Addison, TX 75001 (972) 392-3222 (FAX) 392-0102 TI!XA8 LETTER OF TRANSMITTAL April 4, 2008 RE: Bethel Road - Coppell City of CoppeII P.O. Box 9478 Coppell, TX 75019 A TTN: Ms. Carol Dye ECS Job # 19:5061 Pennits: Location: Bethel Road Coppell, TX We are enclosing: -X..... Materials Engineering Division Reports -X..... For your use -X..... As requested CC: TISEO Paving - Robert Caudill City of Coppell - Rick O'Dell ENCL: Field Report # 165 Field Report # 166 04/03/2008 04/02/2008 td~~~~ Principal Engineer ~c~. Eric L. Branch, C.E.T. Project Manager '" ECS Texas. LLP ~ 4950 Keller Springs Road, Suite 480 Addison, TX 75001 P (972) 392-3222 (FAX) 392-0102 FIELD REPORT Project No. Report No. Day & Date Weather On-Site Time Lab Time Travel Time* Total Re Obs.Time TI!!XA8 Project Bethel Road - Coppell Location Coppell, TX Client City of Coppell - Carol Dye Remarks 19:5061 165 Thursday 04/03/2008 700/ Sunny 6.50 0.00 1.00 7.50 0.00 Trip Charges* 18.00 Chargeable Items T olls/Parking* Mileage* Time of Arrival Departure 07:00A 01:30P * Travel time and mileage will be billed in accordance with the contract. Summary of Services Performed (field test data, locations, elevations & depths are estimates) & Individuals Contacted. The undersigned arrived on site, as requested, to observe: 1. The placement of 300 cubic yards of 3500 psi concrete for paving on Bethel Rd from Sta. 61 +30 to Sta. 64+40. The required test limits were determined to be a slump of 2-5 inches, air content of 3-5 %, batch to placement time of <90 minutes, and concrete temperature range of 50-90 degrees Fahrenheit. Concrete observed on this date appeared to be placed in compliance with project specifications with regard to temperature, slump, air content, and batch to placement time. The following samples were obtained for compressive strength testing in our laboratory: SetA: 1 set of 6 lab cylinders (3500 psi) for paving SetB: I set of 6 lab cylinders (3500 psi) for paving Set C: 1 set of 6 lab cylinders (3500 psi) for paving By Yaw B. Boaitey, - Field Technician 1800 94496 ... ECS Texas. LLP ~ 4950 Keller Springs Road, Suite 480 Addison, TX 75001 (972) 392-3222 (FAX) 392-0102 FIELD REPORT TI!XA8 Project No. Report No. Day & Date Weather On-Site Time Lab Time Travel Time* Total Re Obs. Time 19:5061 166 Wednesday 04/02/2008 650/ Sunny 10.75 0.00 1.00 11.75 0.00 Project Bethel Road - Coppell Location Coppell, TX Client City of Coppell - Carol Dye Remarks Trip Charges* Chargeable Items 18.00 Tolls/Parking* Mileage* Time of Arrival Departure 08:00A 06:45P * Travel time and mileage will be billed in accordance with the contract. Summary of Services Perfonned (field test data, locations, elevations & depths are estimates) & Individuals Contacted. The undersigned arrived on site, as requested, to observe: 1. The placement of 800 cubic yards of 3500 psi concrete for paving. The required test limits were determined to be a slump of 2-5 inches, air content of 3-5 %, batch to placement time of <90 minutes, and concrete temperature range of 50-90 degrees Fahrenheit. Concrete observed on this date appeared to be placed in compliance with project specifications with regard to temperature, slump, air content, and batch to placement time. The following samples were obtained for compressive strength testing in our laboratory: SetA: 1 set of 6 lab cylinders (3500 psi) for Paving Set B: 1 set of 6 lab cylinders (3500 psi) for Paving Set C: 1 set of 6 lab cylinders (3500 psi) for Paving Set 0: 1 set of 6 lab cylinders (3500 psi) for Paving By Yaw B. Boaitey, - Field Technician 1800 94497 IV ECS Texas. LLP E 4950 Keller Springs Road, Suite 480 Addison, TX 75001 (972) 392-3222 (FAX) 392-0102 FIELD REPORT Project No. Report No. Day & Date TI!XAS Project Bethel Road - Coppell Set E: 1 set of 6 lab cylinders (3500 psi) for Paving Set F: 1 set of 6 lab cylinders (3500 psi) for Paving Set G: 1 set of 6 lab cylinders (3500 psi) for Paving SetH: 1 set of 6 lab cylinders (3500 psi) for Paving SetK: 1 set of 6 lab cylinders (3500 psi) for Paving 19:5061 166 VVednesday 04/02/2008 By Yaw B. Boaitey, - Field Technician Page 2 1800 94497