ST9905-LR070403 Concrete Cylinders Strength Report " ECS Texas, LLP ~ 4950 Keller Springs Road, Suite 480 Addison, TX 75001 (972) 392-3222 (FAX) 392-0102 _T1!XA8 Project: Location: Bethel Road - Coppell Bethel Road, Coppell, TX Project: 5061 Cast Date: Design Strength: Report No.: Set Designation: A 04/03/2008 3500 psi 132 Owner: City of Coppell - Carol Dye Client: City of Coppell - Kenneth M. Griffin, Arch.: Gen. Contr.: Struc. Eng.: Cone. Contr.: Placement Location: Paving, Eastbound Bethel, North side, from stations 61 +30 to 64+40, sampled approximately sta 62+00 Concrete Supplier: Tiseo Paving Company Mix Designation: 2478H Added Water: Truck No: 164 Mix Strength: 3500 pSI Time Added: Ticket No: 10 Batch Time: 07:20AM Unit Wt.: FIELD TEST DATA: Tested by: Yaw B. Boaitey Temperature - Air: 700 F Time Sampled:07:45AM Concrete: 720 F Slump:4.00 in. Air Content:3.50 % (P) Sample Test Test Type Diameter Area Breaking Compr. Brk Break Review No Date Age Cure In. In.2 Load,lbs Str.,psi Typ by by 39804 04/08/2008 5 Lab 4.00 12.56 50976 4060 3 ELBl 39805 04/1 0/2008 7 Lab 4.00 12.56 39806 05/01/2008 28 Lab 4.00 12.56 39807 05/01/2008 28 Lab 4.00 12.56 39808 05/0112008 28 Lab 4.00 12.56 39809 OS/29/2008 56 Lab 4.00 12.56 . . . . Sampling In accordance with (law) ASTM C 172, except that samples may have been taken from the begmnlng of the load after a minimum discharge of approximately one cubiC yard. Cylinder molding and laboratory curing iaw ASTM C31, compressive strength test and break type iaw ASTM C39, slump iaw C143, air content iaw ASTM C173 (V) or C231 (P), temperature iaw ASTM C1 064, and unit weight iaw ASTM C138. Cylinders are tested using unbonded caps iaw ASTM C1231 or are capped using sulphur mortar iaw C617. Break Types are classified as: Type 1,2,3,4,5, or 6 iaw C39-04a FIELD CURING CONDITIONS: Curing Box X No Curing Box Remarks: Insulated Heated Cooled X Caps Ice Other Final Review By: ELB1 Print Date: 04/09/2008 Concrete Cylinders Strength Report ~ ECS Texas, LLP ~ 4950 Keller Springs Road, Suite 480 Addison, TX 7500] (972) 392-3222 (FAX) 392-0102 _TI!!XAS Project: Location: Bethel Road - Coppell Bethel Road, Coppell, TX Project: 5061 Cast Date: Design Strength: Report No.: Set Designation: B 04/03/2008 3500 psi 133 Owner: City of Coppell - Carol Dye Client: City of Coppell - Kenneth M. Griffin, Arch.: Gen. Contr.: Struc. Eng.: Conc. Contr.: Placement Location: Paving, Eastbound Bethel, North side, from stations 61 +30 to 64+40, sampled approximately sta 63+00 Concrete Supplier: Tiseo Paving Company Mix Designation: 2478M Added Water: Truck No: 161 Mix Strength: 3500 pSI Time Added: Ticket No: 90 Batch Time: 10:03AM Unit Wt.: FIELD TEST DATA: Tested by: Yaw B. Boaitey Temperature - Air: 740 F Time Sampled: 1 0:50AM Concrete: 750 F Slump:4.25 in. Air Content:3.50 % (P) Sample Test Test Type Diameter Area Breaking Compr. Brk Break Review No Date Age Cure In. In.2 Load,lbs Str.,psi Typ by by 39810 04/08/2008 5 Lab 4.00 12.56 57472 4570 3 ELB1 39811 04/1 0/2008 7 Lab 4.00 12.56 39812 05/01/2008 28 Lab 4.00 12.56 39813 05/01/2008 28 Lab 4.00 12.56 39814 05/01/2008 28 Lab 4.00 12.56 39815 OS/29/2008 56 Lab 4.00 12.56 . . . . Sampling In accordance With (law) ASTM C172, except that samples may have been laken from the beginning of the load after a minimum discharge of approximately one cubiC yard. Cylinder molding and laboratory curing iaw ASTM C31, compressive strength test and break type iaw ASTM C39, slump iaw C143, air content iaw ASTM C173 (V) or C231 (P), temperature iaw ASTM C1064, and unit weight iaw ASTM C138. Cylinders are tested using unbonded caps iaw ASTM C1231 or are capped using sulphur mortar iaw C617. Break Types are classified as: Type 1,2,3,4, 5, or 6 iaw C39-04a FIELD CURING CONDITIONS: Curing Box X No Curing Box Remarks: Insulated Heated Cooled X Caps Ice Other Final Review By: ELBl Print Date: 04/09/2008 ~ ECS Texas, LLP ~ 4950 Keller Springs Road, Suite 480 Addison, TX 7500] (972) 392-3222 (FAX) 392-0102 _T1!XAII Concrete Cylinders Strength Report Project: Location: Bethel Road - Coppell Bethel Road, Coppell, TX Project: 5061 Cast Date: Design Strength: Report No.: Set Designation: C 04/03/2008 3500 psi 134 Owner: City of Coppell - Carol Dye Client: City of Coppell - Kenneth M. Griffin, Arch.: Gen. Contr.: Struc. Eng.: Conc. Contr.: Placement Location: Paving, Eastbound Bethel, North side, from stations 61 +30 to 64+40, sampled approximately sta 63+20 Concrete Supplier: Tiseo Paving Company Mix Designation: 2478M Added Water: Truck No: 163 Mix Strength: 3500 pSI Time Added: Ticket No: 220 Batch Time: 11 :58AM Unit Wt.: FIELD TEST DATA: Tested by: Yaw B. Boaitey Temperature - Air: 750 F Time Sampled:12:45PM Concrete: 760 F Slump:4.00 in. Air Content:3.50 % (P) Sample Test Test Type Diameter Area Breaking Compr. Brk Break Review No Date Age Cure In. In.2 Load,lbs Str.,psi Typ by by 39816 04/08/2008 5 Lab 4.00 12.56 61600 4900 3 ELBl 39817 04/1 0/2008 7 Lab 4.00 12.56 39818 05/01/2008 28 Lab 4.00 12.56 39819 05/01/2008 28 Lab 4.00 12.56 39820 05/01/2008 28 Lab 4.00 12.56 39821 OS/29/2008 56 Lab 4.00 12.56 . . Sampling In accordance with (law) ASTM C172, except that samples may have been taken from the beginning of the load after a minimum discharge of approximately one cubiC yard. Cylinder molding and laboratory curing iaw ASTM C31, compressive strength test and break type iaw ASTM C39, slump iaw C143, air content iaw ASTM C173 (V) or C231 (P), temperature iaw ASTM C1064, and unit weight iaw ASTM C138. Cylinders are tested using unbonded caps iaw ASTM C1231 or are capped using sulphur mortar iaw C617. Break Types are classified as: Type 1,2,3,4,5, or 6 iaw C39-04a FIELD CURING CONDITIONS: Curing Box X No Curing Box Remarks: Insulated Heated Cooled X Caps Ice Other Final Review By: ELBl Print Date: 04/09/2008