Loading...
ST9905-LR070402 '" ECS Texas, LLP ~ 4950 Keller Springs Road, Suite 480 Addison, TX 75001 (972) 392-3222 (FAX) 392-0102 CONCRETE, GROUT, AND MORTAR TESTS LETTER OF TRANSMITTAL TI!XA8 TO: City of Coppell P.O. Box 9478 DATE: 04/02/2008 RE: Bethel Road - Coppell Coppell, TX 75019 A TTN: Ms. Carol Dye PERMIT #: JOB NO.: 005061 LOCATION: Bethel Road, Coppell, TX We are enclosing: X Attached Materials Engineering Division Concrete Reports: 125, 130 X X For Your Use X As Requested CC: TISEO Paving - Robert Caudill City of Coppell - Rick O'Dell David A.t1I:/L Principal Engineer ~3~ Eric L. Branch, C.E.T. Project Manager By: Concrete Cylinders Strength Report ~ ECS Texas, LLP ~ 4950 Keller Springs Road, Suite 480 Addison, TX 75001 (972) 392-3222 (FAX)392-0 102 _TI!XAS Project: Location: Bethel Road - Coppell Bethel Road, Coppell, TX Project: 5061 Cast Date: Design Strength: Report No.: Set Designation: A 03/05/2008 4000 psi 125 Owner: City of Coppell - Carol Dye Client: City of Coppell - Kenneth M. Griffin, Arch.: Gen. Contr.: Struc. Eng.: Conc. Contr.: Placement Location: Box culvert top, 330 ft West of the NE comer of the Minyards NE comer, 45 ft N of door 113 Concrete Supplier: LMC Mix Designation: 1851 Added Water: Truck No: 1002 Mix Strength: 4000 pSI Time Added: Ticket No: 3245649 Batch Time: 04:07PM Unit Wt.: FIELD TEST DATA: Tested by: David L. Hunt Temperature - Air: 620 F Time Sampled:03 :02PM Concrete: 720 F Slump:5.40 in. Air Content:2.60 % (P) Sample Test Test Type Diameter Area Breaking Compr. Brk Break Review No Date Age Cure In. In.2 Load,lbs Str.,psi Typ by by 39406 03/12/2008 7 Lab 4.00 12.56 79712 6340 3 ELBl 39407 03/12/2008 7 Lab 4.00 12.56 79488 6330 3 ELBl 39408 03/1212008 7 Lab 4.00 12.56 73344 5840 3 ELBl 39409 04/0212008 28 Lab 4.00 12.56 92800 7380 3 ELBl 39410 04/02/2008 28 Lab 4.00 12.56 96992 7720 3 ELBl 39411 04/0212008 28 Lab 4.00 12.56 90592 7210 3 ELBl . . . . Sampling In accordance With (law) ASTM C 172, except that samples may have been taken from the beginning of the load after a minimum discharge of approXimately one cubiC yard. Cylinder molding and laboratory curing iaw ASTM C31, compressive strength test and break type iaw ASTM C39, slump iaw C143, air content iaw ASTM C173 (V) or C231 (P), temperature iaw ASTM C1064, and unit weight iaw ASTM C138. Cylinders are tested using unbonded caps iaw ASTM C1231 or are capped using sulphur mortar iaw C617. Break Types are classified as: Type 1, 2, 3, 4, 5, or 6 iaw C39-04a FIELD CURING CONDITIONS: Curing Box X No Curing Box Remarks; Insulated Heated Cooled X Caps Ice Other Final Review By: j/Jt{~_.~ ELBl Print Date: 04/02/2008 Concrete Cylinders Strength Report ~ EeS Texas, LLP ~ 4950 Keller Springs Road, Suite 480 Addison, TX 75001 (972) 392-3222 (FAX) 392-0102 _TDAS Project Location: Bethel Road - Coppell Bethel Road, Coppell, TX Project: 5061 Cast Date: Design Strength: Report No.: Set Designation: A 03/26/2008 3500 psi 130 Owner: City of Coppell - Carol Dye Arch.: Struc. Eng.: Placement Location: North Box culvert walls, Client: City of Coppell - Kenneth M. Griffin, Gen. Contr.: Cone. Contr.: 51 +00 to 52+00, sampled at North most wall Concrete Supplier: LMC Mix Designation: 1701 Added Water: Truck No: 966 Mix Strength: 3600 pSI Time Added: Ticket No: 3246212 Batch Time: 01 :56PM Unit Wt.: FIELD TEST DATA: Tested by: Jonathan E. Steiner Temperature - Air: 770 F Time Sampled:02:28PM Concrete: 800 F Slump: 5.00 in. Air ContentO.80 % (P) Sample Test Test Type Diameter Area Breaking Compr. Brk Break Review No Date Age Cure In. In.2 Load,lbs Str.,psi Typ by by 39718 04/02/2008 7 Lab 4.00 12.56 49504 3940 3 ELBl 39719 04/02/2008 7 Lab 4.00 12.56 54035 4300 3 ELBl 39720 04/23/2008 28 Lab 4.00 12.56 39721 04/23/2008 28 Lab 4.00 12.56 39722 04/23/2008 28 Lab 4.00 12.56 39723 OS/21/2008 56 Lab 4.00 12.56 Sampling in accordance with (iaw) ASTM C172. except that samples may have been taken from the beginning of the load after a minimum discharge of approximately one cubic yard. Cylinder molding and laboratory curing iaw ASTM C31, compressive strength test and break type iaw ASTM C39, slump iaw C143, air content iaw ASTM C173 (V) or C231 (P), temperature iaw ASTM C1064, and unit weight iaw ASTM C138. Cylinders are tested using unbonded caps iaw ASTM C1231 or are capped using sulphur mortar iaw C61? Break Types are classified as; Type 1, 2, 3, 4, 5, or 6 iaw C39-04a FIELD CURING CONDITIONS: Curing Box Insulated X No Curing Box Heated Remarks: Air content does not meet project specifications. Cooled X Caps Ice Other Final Review By: ELBl Print Date: 04/02/2008