ST9905-LR070327 '" ECS Texas. LLP E 4950 Keller Springs Road, Suite 480 Addison, TX 75001 P (972) 392-3222 (FAX) 392-0102 FIELD REPORT Project No. Report No. Day & Date TI!XAS Project Bethel Road - Coppell 1 set of 6 lab cylinders (3600 psi) for box culvert walls 19:5061 162 Thursday 03/27/2008 By Jonathan E. Steiner, - Field Technician Page 2 1800 94406 Q) Ol m 0.. CI) C) ::::s ca C) ... ca CI) U ::::s Z ~ ~ ca E E ::::s en c o ;; (,) ca Q. E o o " :i LL 00 Q r-- ~ M o Q) .... m o Q) ~ m C!l II)N N N ~ 'V ... m Q) "0 ~ Z "'C o 00 ~ ..... Q) ~ ~ ci ~ f/) Z "5 N ~ Q) .c W Ol E ..... ~ ~ 0 ~ ::r: g Q) a. a. o () "0 m o ~ Q) ~ .... Q) CO Qj E m Z o Q) "e- o.. ..... (0 o II) o Z o Q) '[ 0.. Q) a. a. o () - o ~ 6 .... c: "~ l5 i I ... m Q) "0 ~ Z "0 Q) Ui :.::i Q) c: o Z i..: ~ f! .... c: o () D.. ..J ..J en ~ w l- t/) (,) w "'C BCi5 (f) Gl ~5 "ii) 1;) 5i '0 c:!: ci GlQjZ ~ "8 ..: :!::!:~ o o m N u ~ c.. o "0 Q) 13 ~ ..... o <..) c :::> o 00 m 00 ~ "00 c Q) o X co ::2: "'C Q) 13 ~ o <..) c ~ "0 o ~ - Q) ~ ... o 000 em 0..<9 "Eo m~ -gl- Sen en~ "0 o ~ - Q) ~ ... Q) c: 'Q) U5 u..i c: m ~ .... III c:: o ..., C m :Q c:: ~ o Q) I- ... o o e 0.. Gl E ~ >- III C3 >- "'C c: m- ena! ~iil ... ~ C!ll- c:: ,2 Q. ";:: o f/) Gl o N (0 'V ..... Qj c.. E m en 1Il .... C Gl E E o () u. c.. (II 1il Cl en ~ ~ ci.~ eE~ ~8- e!c; ~~~ 00- ~() ~ ~"iij '0 Clco. ~- ~ Q) "iij '0 :s: C 0. ~- ] ~ e c ilE~B'O' t: - .- " ~ aoo- 8o::EU "0 E B ::I U E g- o ~ U::E C'~C' 058- 0- Gl N ~ .~ o Gl > o -> ~Gl ::iiIi -c c:: 0 o+:i :;::::;~ ~ 0 (f)...J ilR ~~ - al ","0 al 0 I-~ en " al 0 I-Z o o cO ..... u ~ c.. o "0 ~ <..) ~ ..... o <..) c ~ o N cO m ~ '00 c Q) o X CO ~ "0 Q) 13 ~ ..... o u c ~ "0 o ~ .... Gl ~ ... o 000 em 0..<9 "EO m~ "01- ffien U5~ "0 o ~ - Q) ~ ... o o e 0.. Q) E :.::i - >- m U >- "0 c: m en c:: ~ co C o :;::::; a. ";:: o f/) Q) o <b 'V ..... Qj c.. E m en 1Il C Gl E E o () u. c.. c; , al o.~ eE~ alO- a..() (II 1il Cl en ~ ~"E: .i ~ ~ 00- ~() ~~'5" ClCo. ~- ~ Gl "iij '0 :s: c 0. ~- 1l~~c Ys~8~ t: ,- ,- " ~ 0.00- 8o::EU "0 ~ 0 ~ e c- C' g .~ 0 5 8- 8::E o~ Gl N :::e .~ o Gl > o - > ~Gl ::iiIi - "'C $ m ~ I- --c:: c 0 0:;::::; :;::::;~ ~o (f)...J ~ I/) r-- ~ o :s: a.. a.. mM mcD mm C!o ..... ci NN .....~ cO 'V m m I'-: II) 00 M ..... ..... ..... ..... 00 00 cOcO ..... ..... 00 NN cOcO m m 00 00 cici C!lC!l en en ~ m o en .::.:: o m co II en CD 11)0 r-- 0 + + CD 'V CD CD c:: c: o 0 :;; :;; m m - .... f/) f/) - - m m olOl c: c:: "S; 'S; m m 0..0.. c: o "iij f/) "E f/) c: m ... I- o ~ is II I- o Qj "0 o ~ il= e 5r a..Cl 00 00 - al "'"8 ~~ bb i ci t-Z - f/) ~ ..... N '" ECS Texas. LLP E 4950 Keller Springs Road, Suite 480 Addison, TX 75001 (972) 392-3222 (FAX) 392-0102 FIELD REPORT Project No. Report No. Day & Date Weather On-Site Time Lab Time Travel Time. Total Re Obs.Time TI!XAS Project Bethel Road - Coppell Location Coppell, TX Client City of Coppell - Carol Dye Remarks 19:5061 162 Thursday 03/27/2008 750/ Sunny 4.25 0.00 1.00 5.25 0.00 Trip Charges. 18.00 Tolls/Parking. Mileage. Time of Arrival Departure 1l:30A 03:45P Chargeable Items 1 - Nuclear Gauge Rental * Travel time and mileage will be billed in accordance with the contract. Summary of Services Performed (field test data, locations, elevations & depths are estimates) & Individuals Contacted. The undersigned arrived on site, as requested, to observe: I: The placement and compaction of soils for paving. 2. The placement of 20 cubic yards of 3600 psi concrete for box culvert walls. Utilizing the nuclear gauge test method to check the compaction of soils; test results indicated that the compacted material, at the areas and elevations tested, met or exceeded the project requirements of 95% of the maximum dry density as obtained in our laboratory using the Standard Proctor Method (ASTM D-698). Locations and elevations of all tests are based on stakeout provided by others. We cannot be responsible for structures located off of the observed engineered pad, misaligned utilities or stakeout errors causing uncontrolled fill to be placed in structural areas. The soils observed on this date appeared to be placed in accordance with project drawings and specifications with regard to lift thickness and moisture content. The required test limits for the concrete tested were determined to be a slump of 3-5 inches, batch to placement time of <90 minutes, and concrete temperature range of <90 degrees Fahrenheit. Concrete observed on this date appeared to be placed in compliance with project specifications with regard to temperature, slump, and batch to placement time. The air content of the concrete tested was 1.9 percent and is less than the project specifications. The following samples were obtained for compressive strength testing in our laboratory: SetA: By Jonathan E. Steiner, - Field Technician 1800 94406 '" ECS Texas, LLP gs: 4950 Keller Springs Road, Suite 480 Addison, TX 75001 (972) 392-3222 (FAX) 392-0]02 CONCRETE, GROUT, AND MORTAR TESTS LETTER OF TRANSMITTAL TI!XA8 TO: City of Coppell P.O. Box 9478 DATE: 03/27/2008 RE: Bethel Road - Coppell Coppell, TX 75019 ATTN: Ms. Carol Dye PERMIT #: JOB NO.: 005061 LOCATION: Bethel Road, Coppell, TX Weare enclosing: X Attached Materials Engineering Division Concrete Reports: 121 X X For Your Use X As Requested CC: TISEO Paving - Robert Caudill City of Coppell - Rick O'Dell By: """"",,,,,,,,,.., _-~.. €. OF r \'111 _- ~,?-~.........E:.t-1 II ~:0o'" ......<9\ i *.:'~_"--"- '" .", '0' ft' _." < '^'" 0'" <..'",.,.. ,.. .., , MARK R ZORTMAN.. ~.___ ~, . . . . .. .....:....t Mark R. Zo~, P.!I9.872 81_ 2008 Principal Engi~f~:cn~s'C;/:f J " 0's ....... ..;.0 - /'l( SIONAL ~ ....-- t l.\\ \'\\'\.",.:...,.......- ~((~ Eric L. Branch, C.E.T. Project Manager ~ ECS Texas, LLP ~ 4950 Keller Springs Road, Suite 480 Addison, TX 75001 (972) 392-3222 (FAX) 392-0102 _1'I!XA8 Concrete Cylinders Strength Report Project: Bethel Road - Coppell Location: Bethel Road, Coppell, TX Owner: City of Coppell - Carol Dye Client: Arch.: Gen. Contr.: Struc. Eng.: Cone. Contr.: Placement Location: Box culvert tops, from sta 48+00 to 47+00, sampled at approximately sta 47+25 Project: 5061 Cast Date: Design Strength: Report No.: Set Designation: A 02/27/2008 3600 psi 121 City of Coppell - Kenneth M. Griffin, Concrete Supplier: LMC Mix Designation: 1701 Added Water: 10 Gals. Truck No: 7069 Mix Strength: 4500 psi Time Added: 02:50PM Ticket No: 3245267 Batch Time: 02:06PM Unit Wt.: FIELD TEST DATA: Tested by:Jonathan E. Steiner Temperature - Air: 700 F Time Sampled:03 :OOPM Concrete: 730 F Slump: 6.00 in. Air Content:} .90 % (P) Sample Test Test Type Diameter Area Breaking Compr. Brk Break Review No Date Age Cure In. In.2 Load,lbs Str.,psi Typ by by 39341 03/05/2008 7 Lab 4.00 12.56 49760 3960 3 ELBl 39342 03/26/2008 28 Lab 4.00 12.56 4 39343 03/26/2008 28 Lab 4.00 12.56 77024 6130 3 ELBl 39344 03/26/2008 28 Lab 4.00 12.56 75872 6040 3 ELBl . . . . Sampling In accordance WIth (law) ASTM Cl72, except that samples may have been taken from the beglnntng of the load after a mlntmum discharge of approximately one cubiC yard. Cylinder molding and laboratory curing iaw ASTM C3l, compressive strength test and break type iaw ASTM C39, slump iaw C143, air content iaw ASTM C173 M or C23l (P), temperature iaw ASTM Cl064, and unit weight iaw ASTM C138. Cylinders are tested using un bonded caps iaw ASTM C123l or are capped using sulphur mortar iaw C6l7. Break Types are classified as: Type 1, 2, 3, 4, 5, or 6 iaw C39-04a FIELD CURING CONDITIONS: Curing Box X No Curing Box Remarks: Insulated Heated Cooled X Caps Ice Other Final Review By: ~- __'0 ELBl Print Date: 03/27/2008