ST9905-LR070325 Concrete Cylinders Strength Report ~ ECS Texas, LLP gs: 4950 Keller Springs Road, Suite 480 Addison, TX 75001 (972) 392-3222 (FAX) 392-0102 _TI!XAS Project: Location: Bethel Road - Coppell Bethel Road, Coppell, TX Project: 5061 Cast Date: Design Strength: Report No.: Set Designation: A 03/25/2008 3500 psi 129 Owner: City ofCoppell- Carol Dye Arch.: Struc. Eng.: Placement Location: Box culvert floor slab, Client: City of Coppell - Kenneth M. Griffin, Gen. Contr.: Cone. Contr.: 51 +00 to 52+00, sampled at approximatly 51 +90 Concrete Supplier: LMC Mix Designation: 1701 Added Water: Truck No: 50220 Mix Strength: 3600 pSI Time Added: Ticket No: 3426153 Batch Time: 01 :25PM Unit Wt.: FIELD TEST DATA: Tested by: Jonathan E. Steiner Temperature - Air: 700 F Time Sampled:02:33PM Concrete: 770 F Slump: 5.00 in. Air Content:l.60 % (P) Sample Test Test Type Diameter Area Breaking Compr. Brk Break Review No Date Age Cure In. In.2 Load,lbs Str.,psi Typ by by 39712 04/01/2008 7 Lab 4.00 12.56 48288 3840 ELBl 39713 04/01/2008 7 Lab 4.00 12.56 50144 3990 ELBl 39714 04/22/2008 28 Lab 4.00 12.56 39715 04/22/2008 28 Lab 4.00 12.56 39716 04/22/2008 28 Lab 4.00 12.56 39717 OS/20/2008 56 Lab 4.00 12.56 Sampling in accordance with (iaw) ASTM C172, exceplthat samples may have been taken from the beginning of the load after a minimum discharge of approximately one cubic yard. Cylinder molding and laboratory curing iaw ASTM C31, compressive strength test and break type iaw ASTM C39, slump iaw C143, air content iaw ASTM C173 (V) or C231 (P), temperature iaw ASTM C1064, and unit weight iaw ASTM C138. Cylinders are tested using unbonded caps iaw ASTM C1231 or are capped using sulphur mortar iaw C617. Break Types are classified as: Type 1,2,3,4,5, or 6 iaw C39-04a FIELD CURING CONDITIONS: Curing Box Insulated X No Curing Box Heated Remarks: Box culvert slab 100ft east of north east comer of minyards (air content less than project Cooled X Caps Ice Other Final Review By: ELBl Print Date: 04/01/2008 , . CONCRETE, 6ROUT, A~d' MORTAR TESTS LETTER .oF TRANSMITTAL '" ECS Texas, LLP E' 4950 Keller Springs Road, Suite 480 Addison, TX 75001 . (972) 392-3222 , LLP (FAX) 392-0102 === TO: City ofCoppell P.O. Box 9478 DATE: 03/25/2008 RE: Bethel Road - Coppell Coppell, TX 75019 A TTN: Ms. Carol Dye PERMIT #: JOB NO.: 005061 LOCATION: Bethel Road, Coppell, TX We are enclosing: X Attached Materials Engineering Division Concrete Reports: 118, 119 x X For Your Use X As Requested CC: TISEO Paving - Robert Caudill City of Coppell - Rick O'Dell aJ~L Davicf A. Lewis, P .E. Principal Engineer ~3~ Eric L. Branch, C.E.T. Project Manager By: Concrete Cylinders Strength Report N ECS Texas, LLP gs: 4950 Keller Springs Road, Suite 480 . Addison, TX 75001 (972) 392-3222 (FAX) 392-0102 TII!XA8 Project: Location: Bethel Road - Coppell Bethel Road, Coppell, TX Project: 5061 Cast Date: Design Strength: Report No.: Set Designation: A 02/26/2008 3600 psi 118 Owner: City of Coppell - Carol Dye Arch.: Struc. Eng.: Client: City of Coppell - Kenneth M. Griffin, Gen. Contr.: Cone. Contr.: Placement Location: Paving, approximately 60' S of center island of Royal at Bethel intersection. " Concrete Supplier: Tiseo Paving Company Mix Designation: 2478H Added Water: Truck No: 166 Mix Strength: 3600 pSI Time Added: Ticket No: Batch Time: 09:05AM Unit Wt.: FIELD TEST DATA: Tested by: Michael J. Cochran Temperature - Air: 500 F Time Sampled:09:45AM Concrete: 620 F Slump:6.00 in. Air Content:4.80 % (P) Sample Test Test Type Diameter Area Breaking Compr. Brk Break Review No Date Age Cure In. In.2 Load,lbs Str.,psi Typ by by 39204 03/04/2008 7 Lab 4.00 12.56 61056 4860 3 ELBl 39205 03/2512008 28 Lab ,4.00 12.56 71776 5710 ELBl 39206 03/25/2008 28 Lab 4.00 12.56 77056 6130 ELBl 39207 04/22/2008 56 Lab 4.00 12.56 . . . . Sampling In accordance with (law) ASTM C172, except that samples may have been taken from the beginning of the load after a minimum discharge of approximately one cubiC yard. Cylinder molding and laboratory curing iaw ASTM C31, compressive,strength test and break type iaw ASTM C39, slump iaw C143, air content iaw ASTM C173 M or C231 (P), temperature iaw ASTM C1064, and unit weight iaw ASTM C136, Cylinders are tested using unbonded caps iaw ASTM C1231 or are capped using sulphur mortar iaw C617. Break Types are classified as: Type 1,2,3,4,5, or 6 iaw C39-04a FIELD CURING CONDITIONS: Curing Box X No Curing Box Remarks: Insulated Heated Cooled X Caps Ice Other Final Review By: /JJtf L r ELBl Print Date: 03/25/2008 Project: Location: Bethel Road - Coppell Bethel Road, Coppell, TX Concrete Cylinders Strength Report Project: 5061 Set Designation: B Cast Date: 02/26/2008 Design Strength: 4000 psi Report No.: 119 ~ ECS Texas, LLP ~ 4950 Keller Springs Road, Suite 480 Addison, TX 75001 (972) 392-3222 (FAX) 392-0] 02 _TDAS Owner: City of Coppell - Carol Dye Client: City of Coppell - Kenneth M. Griffin, Arch.: Gen. Contr.: Struc. Eng.: Cone. Contr.: Placement Location: Box culvert top, approximately 45' N of southern edge and 25' W of Eastern edge of slab Concrete Supplier: LMC Mix Designation: 1851 Added Water: 7 Gals. Truck No: 1045 Mix Strength: 4000 psi Time Added: 12:00PM Ticket No: Batch Time: Unit Wt.: 7188978 11:19AM FIELD TEST DATA: Tested by:Michael 1. Cochran Temperature - Air: 460 F Time Sampled:12:13PM Concrete: 620 F Slump: 8.50 in. Air Content8.00 % (P) Sample Test Test Type Diameter Area Breaking Compr. Brk Break Review No Date Age Cure In. In.2 Load,lbs Str.,psi Typ by by 39208 03/04/2008 7 Lab 4.00 12.56 47808 3800 3 ELBl 39209 03/25/2008 28 Lab 4.00 12.56 64704 5150 ELBl 39210 03/25/2008 28 Lab 4.00 12.56 63232 5030 ELBl 39211 04/22/2008 56 Lab 4.00 12.56 . . . . Sampling In accordance w~h (law) ASTM Cl72, except that samples may have been taken from the beginning of the load after a minimum discharge of approximately one cubic yard. Cylinder molding and laboratory curing iaw ASTM C31, compressive strength test and break type iaw ASTM C39, slump iaw C143, air cOntent iaw ASTM C173 M or C231 (P), temperabJre iaw ASTM C1064, and unit weight iaw ASTM C138. Cylinders are tested using unbonded caps iaw ASTM C1231 or are capped using sulphur mortar iaw C617. Break Types are classified as: Type 1,2,3,4,5, or 6 iaw C39-04a FIELD CURING CONDITIONS: Curing Box X No Curing Box Remarks: Insulated Heated Cooled X Caps Ice Other Final Review By: tJ~~-~ ELBl Print Date: 03/25/2008