ST9905-LR070324 "' ECS Texas, LLP ~ 4950 Keller Springs Road, Suite 480 Addison, TX 75001 (972) 392-3222 (FAX) 392-0102 CONCRETE, GROUT, AND MORTAR TESTS LETTER OF TRANSMITTAL TD:A8 TO: City of Coppell P.O. Box 9478 DATE: 03/24/2008 RE: Bethel Road - Coppell Coppell, TX 75019 A TTN: Ms. Carol Dye PERMIT #: JOB NO.: 005061 LOCATION: Bethel Road, Coppell, TX We are enclosing: X Attached Materials Engineering Division Concrete Reports: 114,115, 117, 116, 127, 128 X X For Your Use X As Requested CC: TISEO Paving - Robert Caudill City of Coppell - Rick O'Dell By: ........,.... ''''\'''' "'\. _--- '\~. OF rE:~ 'I, __- -<,I'>. . .'o'.."l 'I, '0.~ ; 1i*-i~-~'-'---- ' ,_.,-,.,-;.-~~,', . m... ~o...o,.......; ; , . .... M~rk. R. Z~an~~~ -1242008 PrmcIpal B~~f:o~~~?oo~~ I" "'SION'AI 'i::"\: __- l'l ,.... """..... ,\.\~\.\."".....,......... ~C(~ Eric L. Branch, C.E.T. Project Manager Concrete Cylinders Strength Report ~ ECS Texas, LLP ~ 4950 Keller Springs Road, Suite 480 Addison, TX 75001 (972) 392-3222 (FAX) 392-0 102 _T1!XAS Project: Location: Bethel Road - Coppell Bethel Road, Coppell, TX Project: 5061 Cast Date: Design Strength: Report No.: Set Designation: A 02/21/2008 3600 psi 114 Owner: City of Coppell - Carol Dye Client: City of Coppell - Kenneth M. Griffin, Arch.: Gen. Contr.: Struc. Eng.: Conc. Contr.: Placement Location: Box culvert wans, sampled from the South center wall Concrete Supplier: LMC Mix Designation: 170 I Added Water: 10 Gals. Truck No: 7006 Mix Strength: 3600 pSI Time Added: Ticket No: 6323418 Batch Time: 10:15AM Unit Wt.: FIELD TEST DATA: Tested by: Michael 1. Cochran Temperature - Air: 450 F Time Sampled:ll:15AM Concrete: 660 F Slump:6.25 in. Air Content:5.40 % (P) Sample Test Test Type Diameter Area Breaking Compr. Brk Break Review No Date Age Cure In. In.2 Load,lbs Str.,psi Typ by by 39100 02/28/2008 7 Lab 4.00 12.56 39101 03/21/2008 29 Lab 4.00 12.56 75904 6040 5 ELBl 39102 03/21/2008 29 Lab 4.00 12.56 74336 5920 5 ELBl 39103 04/1 7/2008 56 Lab 4.00 12.56 . . . . Sampling In accordance With (law) ASTM C172, except that samples may have been taken from the beginning of the load after a minimum discharge of approximately one cubic yard. Cylinder molding and laboratory curing iaw ASTM C31, compressive strength test and break type iaw ASTM C39, slump iaw C143, air content iaw ASTM C173 (V) or C231 (P), temperature iaw ASTM C1064, and unit weight iaw ASTM C138. Cylinders are tested using unbonded caps iaw ASTM C1231 or are capped using sulphur mortar iaw C617. Break Types are classified as: Type 1, 2, 3. 4, 5, or 6 iaw C39-04a FIELD CURING CONDITIONS: Curing Box X No Curing Box Remarks: Insulated Heated Cooled X Caps Ice Other Final Review By:-- ~~ c~ . ELBl Print Date: 03/24/2008 Concrete Cylinders Strength Report ~ ECS Texas, LLP ~ 4950 Keller Springs Road, Suite 480 Addison, TX 75001 (972) 392-3222 (FAX) 392-0102 _TI!XAS Project: Location: Bethel Road - Coppell Bethel Road, Coppell, TX Project: 5061 Cast Date: Design Strength: Report No.: Set Designation: E 02/21/2008 3600 psi 115 Owner: City of Coppell - Carol Dye Client: City of Coppell - Kenneth M. Griffin, Arch.: Gen. Contr.: Struc. Eng.: Conc. Contr.: Placement Location: Driveway, 50' East of Royal on Bethel Road Concrete Supplier: Southern Star Mix Designation: 7795 Added Water: Truck No: 948 Mix Strength: 3600 pSI Time Added: Ticket No: 1206561 Batch Time: 12:20PM Unit Wt.: FIELD TEST DATA: Tested by: Jonathan E. Steiner Temperature - Air: 500 F Time Sampled:O 1 :OOPM Concrete: 550 F Slump:4.00 in. Air Content:3.30 % (P) Sample Test Test Type Diameter Area Breaking Compr. Brk Break Review No Date Age Cure In. In.2 Load,lbs Str.,psi Typ by by 39108 02/28/2008 7 Lab 4.00 12.56 68416 5440 ELBl 39109 03/20/2008 28 Lab 4.00 12.56 92640 7370 4 ELBl 39110 03/20/2008 28 Lab 4.00 12.56 96800 7700 3 ELBl 39111 04/17/2008 56 Lab 4.00 12.56 . . . . Sampling In accordance With (law) ASTM C172. except that samples may have been taken from the begmnlng of the load after a minimum discharge of approximately one cubiC yard. Cylinder molding and laboratory curing iaw ASTM C31. compressive strength test and break type iaw ASTM C39. slump iaw C143, air conlent iaw ASTM C173 (V) or C231 (P). temperature iaw ASTM C1064, and unit weight iaw ASTM C138. Cylinders are tested using unbonded caps iaw ASTM C1231 or are capped using sulphur mortar iaw C617. Break Types are classified as: Type 1, 2, 3, 4, 5. or 6 iaw C39-04a FIELD CURING CONDITIONS: Curing Box X No Curing Box Remarks: Insulated Heated Cooled X Caps Ice Other Final Review By: ~~.._- ELB1 Print Date: 03/24/2008 Concrete Cylinders Strength Report ~ ECS Texas, LLP ~ 4950 Keller Springs Road, Suite 480 Addison, TX 75001 (972) 392-3222 (FAX) 392-0102 _TEXAS Project: Location: Bethel Road - Coppell Bethel Road, Coppell, TX Project: 5061 Cast Date: Design Strength: Report No.: Set Designation: A 02/22/2008 3600 psi 117 Owner: City of Coppell - Carol Dye Arch.: Struc. Eng.: Placement Location: Box culvert walls, North wall, Client: City of Coppell - Kenneth M. Griffin, Gen. Contr.: Conc. Contr.: Concrete Supplier: LMC Mix Designation: 1701 Added Water: Truck No: 7069 Mix Strength: 3600 pSI Time Added: Ticket No: 3244961 Batch Time: 11:37 AM Unit Wt.: FIELD TEST DATA: Tested by: Michael J. Cochran Temperature - Air: 440 F Time Sampled:12:27PM Concrete: 610 F Slump: 5.25 in. Air Content:5.70 % (P) Sample Test Test Type Diameter Area Breaking Compr. Brk Break Review No Date Age Cure In. In.2 Load,lbs Str.,psi Typ by by 39124 02/29/2008 7 Lab 4.00 12.56 56064 4460 3 ELBl 39125 03/21/2008 28 Lab 4.00 12.56 80544 6410 5 ELBl 39126 03/21/2008 28 Lab 4.00 12.56 77184 6140 3 ELBl 39127 04/18/2008 56 Lab 4.00 12.56 Sampling in accordance with (iaw) ASTM C172, except that samples may have been taken from the beginning of the load after a minimum discharge of approximately one cubic yard. Cylinder molding and laboratory curing iaw ASTM C31, compressive strength test and break type iaw ASTM C39, slump iaw C143, air content iaw ASTM C173 (V) or C231 (P), temperature iaw ASTM C1064, and unit weight iaw ASTM C138. Cylinders are tested using unbonded caps iaw ASTM C1231 or are capped using sulphur mortar iaw C617. Break Types are classified as: Type 1, 2, 3, 4, 5, or 6 iaw C39-04a FIELD CURING CONDITIONS: Curing Box X No Curing Box Remarks: Insulated Heated Cooled X Caps Ice Other ~ ~ Final Review By: ELBI Print Date: 03/24/2008 Concrete Cylinders Strength Report ~ ECS Texas, LLP ~ 4950 Keller Springs Road, Suite 480 Addison, TX 7500] (972) 392-3222 (FAX)392-0 ] 02 _T1!XA8 Project: Location: Bethel Road - Coppell Bethel Road, Coppell, TX Project: 5061 Cast Date: Design Strength: Report No.: Set Designation: B 02/22/2008 3600 psi 116 Owner: Arch.: Struc. Eng.: Placement Location: Approach to box City of Coppell - Carol Dye Client: Gen. Contr.: Conc. Contr.: CiCi's, approximately 20' E from Wedge of drive and 5' S of dyed concrete City of Coppell - Kenneth M. Griffin, Concrete Supplier: Southern Star Mix Designation: 7795 Added Water: Truck No: 32 Mix Strength: 3600 psi Time Added: Ticket No: 1207624 Batch Time: 12:34PM Unit Wt.: FIELD TEST DATA: Tested by: Michael 1. Cochran Temperature - Air: 590 F Time Sampled:O 1 :05PM Concrete: 650 F Slump: 6.00 in. Air Content:4.70 % (P) Sample Test Test Type Diameter Area Breaking Compr. Brk Break Review No Date Age Cure In. In.2 Load,lbs Str.,psi Typ by by 39116 02/29/2008 7 Lab 4.00 12.56 50752 4040 3 ELBl 39117 03/21/2008 28 Lab 4.00 12.56 79904 6360 3 ELBl 39118 03/21/2008 28 Lab 4.00 12.56 78688 6260 3 ELBl 39119 04/18/2008 56 Lab 4.00 12.56 . . . . Sampling in accordance with (iaw) ASTM C172, except that samples may have been taken from the beginning of the load after a minimum dIScharge of approximately one cubic yard. Cylinder molding and laboratory curing iaw ASTM C31, compressive strength test and break type iaw ASTM C39, slump iaw C143, air content iaw ASTM C173 M or C231 (P), temperature iaw ASTM Cl064, and unit weight iaw ASTM C138. Cylinders are tested using unbonded caps iaw ASTM C1231 or are capped using sulphur mortar iaw C617. Break Types are classified as: Type 1,2,3, 4, 5, or 6 iaw C39-04a FIELD CURING CONDITIONS: Curing Box X No Curing Box Remarks: Insulated Heated Cooled X Caps Ice Other Final Review By: ___~:~:~C> <<-~...------ .,,~---'" ELBl Print Date: 03/24/2008 ~ ECS Texas, LLP ~ 4950 Keller Springs Road, Suite 480 Addison, TX 75001 (972) 392-3222 (FAX) 392-0102 Concrete Cylinders Strength Report _TEXAS Project: Location: Bethel Road - Coppell Bethel Road, Coppell, TX Project: 5061 Cast Date: Design Strength: Report No.: Set Designation: A 03/14/2008 3600 psi 127 Owner: City of Coppell - Carol Dye Client: City of Coppell - Kenneth M. Griffin, Arch.: Gen. Contr.: Struc. Eng.: Cone. Contr.: Placement Location: Box culvert walls, sampled at the middle wall of box culvet @ Sta. 34 + 00 Concrete Supplier: LMC Mix Designation: 1701 Added Water: Truck No: 7024 Mix Strength: 3600 pSI Time Added: Ticket No: 7189556 Batch Time: 08:00AM Unit Wt.: FIELD TEST DATA: Tested by: Yaw B. Boaitey Temperature - Air: 670 F Time Sampled:08:45AM Concrete: 640 F Slump: 5.00 in. Air Content:4.00 % (P) Sample Test Test Type Diameter Area Breaking Compr. Brk Break Review No Date Age Cure In. In.2 Load,lbs Str.,psi Typ by by 39527 03/21/2008 7 Lab 4.00 12.56 56096 4460 5 ELBl 39528 04/11/2008 28 Lab 4.00 12.56 39529 04/1112008 28 Lab 4.00 12.56 39530 05/09/2008 56 Lab 4.00 12.56 Sampling in accordance with (law) ASTM C172, except that samples may have been taken from the beginning of the load after a minimum discharge of approximately one cubic yard. Cylinder molding and laboratory curing iaw ASTM C31, compressive strength test and break type iaw ASTM C39, slump iaw C143, air content iaw ASTM C173 M or C231 (P), temperature iaw ASTM C1 064, and unit weight iaw ASTM C138. Cylinders are tested using unbonded caps iaw ASTM C1231 or are capped using sulphur mortar iaw C617. Break Types are classified as: Type 1,2,3,4,5, or 6 iaw C39-04a FIELD CURING CONDITIONS: Curing Box Insulated X No Curing Box Heated Remarks: middle wall of box culvet @ Sta. 34 + 00 Cooled X Caps Ice Other Final Review By: ELBl Print Date: 03/24/2008 '. ECS Texas, LLP ~ 4950 Keller Springs Road, Suite 480 Addison, TX 75001 (972) 392-3222 (FAX) 392-0102 _TI!XAtI Concrete Cylinders Strength Report Project: Location: Bethel Road - Coppell Bethel Road, Coppell, TX Project: 5061 Cast Date: Design Strength: Report No.: Set Designation: B 03/1412008 4000 psi 128 Owner: City of Coppell - Carol Dye Client: City of Coppell - Kenneth M. Griffin, Arch.: Gen. Contr.: Struc. Eng.: Conc. Contr.: Placement Location: Stamped concrete at the intersection of Royal Lane and Bethel Rd. Concrete Supplier: LMC Mix Designation: 9363 Added Water: Truck No: 84 Mix Strength: 4000 pSI Time Added: Ticket No: 1220436 Batch Time: 09:00AM Unit Wt.: FIELD TEST DATA: Tested by: Yaw B. Boaitey Temperature - Air: 720 F Time Sampled:09:45AM Concrete: 660 F Slump:4.50 in. Air Content:3.80 % (P) Sample Test Test Type Diameter Area Breaking Compr. Brk Break Review No Date Age Cure In. In.2 Load,lbs Str.,psi Typ by by 39531 03/21/2008 7 Lab 4.00 12.56 49216 3920 5 ELBl 39532 04/1112008 28 Lab 4.00 12.56 39533 04/1112008 28 Lab 4.00 12.56 39534 05/09/2008 56 Lab 4.00 12.56 , . . ' Sampling In accordance With (law) ASTM C172. except that samples may have been taken from the beginning of the load after a minimum discharge of approximately one cubic yard. Cylinder molding and laboratory curing iaw ASTM C31. compressive strength test and break type iaw ASTM C39. slump iaw C143. air content iaw ASTM C173 (V) or C231 (P). temperature iaw ASTM C1064. and unit weight iaw ASTM C138. Cylinders are tested using unbonded caps iaw ASTM C1231 or are capped using sulphur mortar iaw C617. Break Types are classified as: Type 1.2.3.4.5. or 6 iaw C39-04a FIELD CURING CONDITIONS: Curing Box Insulated X No Curing Box Heated Remarks: Stamped @ the intersection of Royal Ln and Bethel Rd. Cooled X Caps Ice Other Final Review By: ELBl Print Date: 03/24/2008